ABB Installation Products K650-J3 15/25kV 600 Series Deadbreak 3-point Junction

UPC: 783786654727


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K650-J3 is a 15/25kV, 600A deadbreak 3-way junction designed for reliable medium-voltage cable interconnections. Manufactured by ABB Installation Products, this fully shielded, submersible junction features a peroxide-cured EPDM rubber housing and stainless steel mounting bracket. It meets ANSI/IEEE Standard 386 and provides secure terminations for sectionalizing, looping, tapping, and equipment bypass in subsurface, vault, or padmount applications. Compatible with Elastimold® 600A Series Elbow connectors, the K650-J3 ensures safe, insulated connections with 95kV BIL impulse withstand and 600A continuous current rating.
  • 15/25kV voltage rating with 600A continuous current capacity
  • Fully shielded, submersible molded rubber housing with EPDM materials
  • Meets ANSI/IEEE Standard 386 for medium-voltage applications
  • Compatible with Elastimold® 600A Series Elbow connectors
  • Stainless steel mounting bracket for secure installation

Specifications

Application
Designed for subsurface, vault or padmount applications and can be used for sectionalizing, looping, tapping, and equipment bypass
Connection
Push-In
Connection Type
Deadbreak
Material
EPDM-Rubber
Poles
3
Series
600 Series
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provides mating for Elastimold 600 Amp Series Elbow connectors. Stainless Steel Mounting Bracket
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
3-Way Junction
Voltage Rating
15/25kV
Package Dimensions (L x W x H)
20 IN x 8 IN x 8 IN
Package Dimensions (L x W x H)
50.8 cm x 20.32 cm x 20.32 cm
Package Weight (Imperial)
8.6600 L
Package Weight (Metric)
3.9280 kg
6 Point Junction, with one 600 Amp Bushing Interfaces, four 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, No Tilt Mounting.

J6-622226-25

6 Point Junction, with one 600 Amp Bushing Interfaces, four 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, No Tilt Mounting.
15/25kV 600 Series Deadbreak Insulated Parking Bushing

K650SOP

15/25kV 600 Series Deadbreak Insulated Parking Bushing
Link-Op Alignment Bracket, (Retrofit Link-OP only) 15/25/35kV, Includes Link Op (1) Welded Bracket with (2) Welded Clamp Tops and 3/8 inch Stainless Steel Hardware (4) Hex Head Cap Screws, (4) Lock Washers, (4) Hex Nuts.

650AB

Link-Op Alignment Bracket, (Retrofit Link-OP only) 15/25/35kV, Includes Link Op (1) Welded Bracket with (2) Welded Clamp Tops and 3/8 inch Stainless Steel Hardware (4) Hex Head Cap Screws, (4) Lock Washers, (4) Hex Nuts.
15/25kV 600 Amp Series Deadbreak Elbow Threaded Stud. Aluminum. Electro Tin Plated. Length 2.215 inch. Threaded Length each end .86 inch. 5/8-11 UNC-2A Threaded on Both Ends.

650SA

15/25kV 600 Amp Series Deadbreak Elbow Threaded Stud. Aluminum. Electro Tin Plated. Length 2.215 inch. Threaded Length each end .86 inch. 5/8-11 UNC-2A Threaded on Both Ends.
15/25kV 600 Series Deadbreak Replacement Elbow Housing Only with Test Point

K656BRLR

15/25kV 600 Series Deadbreak Replacement Elbow Housing Only with Test Point
15-25 kV. 600 Amp, Bolt Washers Prepack, (1) Zinc Plated Steel Compression Washer Diameter 1.313 inch with .640/.653 Diameter Hole, (1) Tin Plated Steel Flat Washer 1-1/4 inch Diameter with .656 inch Hole, (1) 304 Stainless Steel Hex Head Cap Screw Machined 5/8-11 UNC-2A Overall Length 1.9 inch. (1) Nylon Rod, (3) Lubricant packets.

650BAW

15-25 kV. 600 Amp, Bolt Washers Prepack, (1) Zinc Plated Steel Compression Washer Diameter 1.313 inch with .640/.653 Diameter Hole, (1) Tin Plated Steel Flat Washer 1-1/4 inch Diameter with .656 inch Hole, (1) 304 Stainless Steel Hex Head Cap Screw Machined 5/8-11 UNC-2A Overall Length 1.9 inch. (1) Nylon Rod, (3) Lubricant packets.
15/25kV 600 Series Deadbreak Bushing Extender - Length 8.41 inch x 3.17 inch Diameter, (with Stud - Length 2.28 inch 5/8-11 UNC-2A Thread)

K655BE

15/25kV 600 Series Deadbreak Bushing Extender - Length 8.41 inch x 3.17 inch Diameter, (with Stud - Length 2.28 inch 5/8-11 UNC-2A Thread)
15/25kV, 600 Series Replacement Elbow Housing only without Test Point.

K655BRLR

15/25kV, 600 Series Replacement Elbow Housing only without Test Point.

Frequently Asked Questions

What is the K650J3 product type?

The K650J3 is a 15/25kV, 600 Amp Deadbreak 3-Way Junction.

What is the impulse withstand rating for the 28kV class?

For the 28kV voltage class, the impulse withstand (BIL) is 140kV (1.2 x 50 microsecond wave).

What is the AC one-minute withstand voltage for 15kV?

For the 15kV voltage class, the AC one-minute withstand is 34kV.

What is the maximum operating voltage for the 28kV class?

For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV and maximum phase-to-phase is 28kV.

What is the AC one-minute withstand voltage for 28kV?

For the 28kV voltage class, the AC one-minute withstand is 45kV.

What standard does the K650J3 junction meet?

The K650J3 junction meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating for the K650J3?

The continuous current rating for the K650J3 is 600 Amp for both 15kV and 28kV voltage classes.

What is the impulse withstand rating for the 15kV class?

For the 15kV voltage class, the impulse withstand (BIL) is 95kV (1.2 x 50 microsecond wave).

What is the maximum operating voltage for the 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and maximum phase-to-phase is 14.4kV.

How is the K650J3 junction mounted?

It is equipped with a stainless steel mounting bracket and back plate suitable for mounting on a flat surface.

How to Install a K650-J3 Series Deadbreak Junction with Universal Mount

This guide provides step-by-step instructions for installing 15/25/35kV, 600/900 Ampere K650-J3 series deadbreak junctions using the universal mounting method.

Estimated time: 1h 30m

Tools needed:

Drill, Wrench set, Measuring tape, Marking tool, Wire strippers, Torque wrench

Supplies needed:

Deadbreak Junction (K650-J3 or similar), Base Bracket, Base Plate, Universal Brackets (4), 3/8" Hex Head Cap Screws, External Tooth Lock Washers, 3/8" Hex Nuts, 1/2" Hex Head Cap Screws, 1/2" Split Lock Washers, 1/2" Hex Nuts, Suitable mounting fasteners (user supplied), Grounding wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricant, Insulated caps (for unused interfaces)

  1. Review Safety Precautions and De-energize

    WARNING: All apparatus must be de-energized during installation or removal of parts. This product should only be installed by competent personnel trained in good safety practices involving high voltage electrical equipment. Failure to follow instructions will result in damage and serious injury. Ensure all apparatus is de-energized before proceeding with installation.

  2. Determine Mounting Location and Mark

    Select the desired location for the junction assembly on a flat surface. Use the base plate as a template, place it on the surface, and mark the four slot locations for mounting.

  3. Attach Initial Universal Brackets

    Secure two (2) universal brackets to the marked surface using suitable fasteners (not supplied). Tighten these fasteners securely to prevent any movement during operation.

  4. Attach Remaining Universal Brackets

    Attach the remaining two (2) universal brackets to the two brackets already mounted on the surface. Position them at the desired angle using the supplied 3/8” hex head cap screws, external tooth lock washers, and 3/8” hex nuts. Tighten securely.

  5. Assemble Junction to Base Bracket and Plate

    Assemble the deadbreak junction to the base bracket assembly and base plate. Use two (2) 1/2” hex head cap screws, two (2) 1/2” split lock washers, and two (2) 1/2” hex nuts, attaching them to the center mounting holes on the bracket assembly. Tighten securely.

  6. Mount Junction Assembly to Universal Brackets

    Attach the complete deadbreak junction assembly (with base bracket and plate) to the universal brackets. Use the supplied 1/2” hex head cap screws, 1/2” split lock washers, and 1/2” hex nuts. Tighten securely, ensuring the parking stand is in the upright position.

  7. Ground the Assembly

    Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket. Ensure the base bracket assembly and the junction’s black conductive jacket are properly grounded.

  8. Prepare Operating Interfaces

    Remove all protective shipping caps from the operating interfaces. Clean each operating interface thoroughly. Lubricate each interface with an ELASTIMOLD approved lubricant. Do not substitute with other lubricants. If any operating interfaces are not utilized, install appropriate HV insulated caps on these unused bushings before energization. Do not use protective shipping caps for this purpose.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.