ABB Installation Products K1601WJ4 15/25 kV, 200 Amp Loadbreak, 4-Way Well Junction with Stainless Steel Bracket
UPC: 783786662975
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25 kV, 200 Amp continuous & loadbreak rating
- 4-way configuration for flexible lateral connections
- Fully shielded, fully submersible molded rubber housing
- Stainless steel bracket for corrosion resistance and structural integrity
- Meets ANSI/IEEE Standard 386 with 95kV/125kV BIL ratings
Specifications
Application | 15/25 kV, 200 Amps |
Connection Type | Loadbreak |
Current Rating | 200 A |
Material | Stainless Steel |
Mounting Type | Stainless Steel Bracket |
Poles | 4-Way |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -4 F |
Temperature Rating, Minimum | -20 C |
Type | Well Junction 4-Way |
Voltage Rating | 15/25 kV |
Package Weight (Imperial) | 0.0010 L |
Package Weight (Metric) | 0.0010 kg |

K675TBC
15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.
K1601WJ4-5
15/25kV 200 Amp, loadbreak 4-way Well Junction with U Straps, Hardware package consists of U Straps and back plate only.
M276BWP
35kV 200 Amp, Loadbreak Bushing Well Plug, Includes Lubricant and Instructions. EPDM Peroxide Insulation. Does Not have the following: Ground Cable, Rivet, Bail Assembly, Spring Plunger or Wiper.
150BA
15/25kV 200 Amp, Deadbreak Bail Assembly for 156LR Elbow. Hold-Down Bail and EyeBolt. 3 inch Inside Width on Bail. 500 Pounds Minimum.Frequently Asked Questions
What are the voltage and current ratings?
The K1601WJ4 is a 15/25kV, 200 Amp Loadbreak 4-Way Well Junction.
What are the 25kV operating voltage ratings?
For 25kV, the operating voltage is 15.2kV Max Phase-to-Ground and 26.3kV Max Phase-to-Phase.
What are the 15kV withstand ratings?
For 15kV, the withstand ratings are 95kV BIL Impulse, 34kV AC one minute, and 53kV DC 15 minutes.
What items are included in the K1601WJ4 kit?
Each kit contains a basic molded junction, mounting hardware, a tube of lubricant, and installation instructions.
Is the stud replaceable, and how do I order one?
The junction is supplied with a replaceable stud. A replacement stud is available separately; specify 1000-150.
What industry standard does the junction meet?
The K1601WJ4 junction meets ANSI/IEEE Standard 386, Latest Revision.
What are the 15kV operating voltage ratings?
For 15kV, the operating voltage is 8.3kV Phase-to-Ground and 14.4kV Max Phase-to-Phase.
What is the maximum inclination for mounting?
The supplied brackets accommodate curved or flat surfaces and provide up to 60° of inclination.
What specific Elastimold products are compatible?
The K1601WJ4 is designed to mate with Elastimold® products including 1601A4, 2701A4, 1602A3R, and 276BWP.
Can the junction be operated energized or de-energized?
Yes, the Elastimold® loadbreak junctions are designed for energized or de-energized operation.
How to Install K1601WJ2, K1601WJ3, or K1601WJ4 Loadbreak Well Junctions
This guide provides step-by-step instructions for mounting and connecting K1601WJ series two-, three-, and four-point loadbreak well junctions on flat or curved surfaces, including grounding and bushing installation.
Estimated time: 1h
Tools needed:
Screwdriver, Wrench, Measuring tape or ruler, Drill
Supplies needed:
Mounting brackets (included), Hardware (included with brackets), Lubricant (included), Bolts (user-supplied, 17/32 inch or 13mm diameter), Grounding wire (No. 10 Solid to No. 1 Stranded), Elastimold bushings (not included), Elastimold insulated cap(s) or plug(s) (if interfaces are unused)
- Safety First: De-energize and Inspect
Before beginning installation, ensure all apparatus is de-energized. Inspect all parts for damage, proper rating, and compatibility with mating components. Failure to follow these instructions will result in damage to the product and serious or fatal injury.
- Prepare and Mark Mounting Bracket Locations
Loosely attach the universal mounting brackets to the junction base bracket. Place the assembled unit against the desired mounting surface (flat or curved). Adjust the brackets for proper alignment and mark their exact location on the wall.
- Mount Universal Brackets to Wall
Detach the universal mounting brackets from the junction base bracket. Mount the brackets securely to the wall according to the marks made in Step 2. Refer to the provided mounting dimensions (A, B, C) for your specific junction part number (J2, J3, or J4) to ensure correct bolt center spacing. Note that one or both brackets can be inverted to adjust the distance between bolt centers. Use user-supplied bolts that fit 17/32” (13mm) diameter holes.
- Attach Junction Base to Mounted Brackets
With the universal mounting brackets securely fastened to the wall, attach the junction base bracket (with the loadbreak well junction already attached) to the mounted brackets. Ensure that the parking stands are in the upright position.
- Adjust and Secure Mounting Angle
Adjust the mounting angle of the junction to your desired position. The angle is adjustable from 0° through 90° above or below the horizontal in 15° increments. Once the desired angle is set, tighten all bolts securely to prevent any movement during operation.
- Ground the Junction Base Bracket
Ground the junction base bracket using the provided grounding lug. This lug is designed to accommodate grounding wire sizes from No. 10 Solid to No. 1 Stranded.
- Prepare Bushing Wells
Remove the protective shipping caps from all bushing wells. Carefully inspect each well to ensure it is completely dry and free from any contaminants. Lubricate the well interface area using only the supplied lubricant or an Elastimold-approved lubricant. Do not substitute with other lubricants, as they may harm the product or its mating components.
- Install Bushings
Install the appropriate Elastimold bushings into the prepared wells. Follow the specific installation instructions provided with the bushings themselves.
- Final Safety Check: Unused Interfaces
Before energizing the circuit, if any operating interfaces on the junction are not utilized, an Elastimold insulated cap or insulated plug MUST be installed on those unused interfaces. Do NOT use the protective shipping covers for this purpose, as they are not insulated and are only intended for cleanliness during handling and installation.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.