ABB - Installation Products 376LR-K2260 - 35kV, 200 Amp, LoadBreak, Elbow Connector with Test Point, Cable Insulation 1.090-1.310 inches, Copper Compression Lug, Conductor Size 3/0 Stranded/Compressed or 4/0 Compact/Solid. No Seal

ABB Installation Products 376LR-K2260 35kV, 200 Amp, LoadBreak, Elbow Connector with Test Point, Cable Insulation 1.090-1.310…

UPC: 075114295789


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 376LR-K2260 is a 35kV, 200 Amp loadbreak elbow connector designed for medium-voltage power distribution systems. This connector provides a reliable, fully shielded interface for terminating medium-voltage cables in loadbreak applications where direct conductor termination is required. The built-in test point enables safe voltage verification during maintenance and troubleshooting without de-energizing the system, reducing downtime and improving operational efficiency. Key specifications include a voltage rating of 35 kV and a continuous current rating of 200 A, making it suitable for medium-voltage distribution networks. The connector accommodates cable insulation diameters ranging from 1.090 to 1.310 inches, ensuring compatibility with a variety of medium-voltage cables. The copper compression lug provides secure electrical termination, supporting conductor sizes of 3/0 AWG stranded/compressed or 4/0 AWG compact/solid, which ensures robust electrical contact and minimal resistance. Its design prioritizes direct functionality and adherence to specified electrical ratings, making it ideal for applications requiring a standard loadbreak connection without sealing. The absence of a seal simplifies installation while maintaining reliable performance in medium-voltage environments. Applications include medium-voltage switchgear, transformers, and other high-voltage apparatus where loadbreak connections are necessary.
  • 35 kV voltage rating for medium-voltage applications
  • 200 Amp continuous current rating
  • Built-in test point for safe voltage verification
  • Accommodates cable insulation diameters from 1.090 to 1.310 inches
  • Copper compression lug for secure electrical termination of 3/0 or 4/0 AWG conductors

Specifications

Amperage Rating
200 A
Application
35 kv, 200 Amp
Color
Black
Conductor Range
3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG
Connection
Push-In
Connection Type
Loadbreak Elbow Connector with Test Point
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Copper Compression Lug
Material
Housing - EPDM-Rubber
Series
376LR-K2260
Size
Cable Insulation 1.090-1.310 inches
Size
Cable Insulation Diameter 1.090 inch to 1.310 inch
Special Features
35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Non-Corrosive Capacitive Voltage Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

376LR-J-5260

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring

167ELR-6689-5220-SG3

15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. No Seal

167ELR-6689-5220

15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. No Seal
35kV, 200 Amp, LoadBreak, Elbow Connector with Test Point, Cable Insulation 1.090-1.310 inches, Bi-Metal Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid. With Jacket Seal

376LR-K5240-S

35kV, 200 Amp, LoadBreak, Elbow Connector with Test Point, Cable Insulation 1.090-1.310 inches, Bi-Metal Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid. With Jacket Seal
25kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow. Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid. No Seal

273ELR-7495-5250

25kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow. Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid. No Seal
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid. No Seal

167ELR-7495-5250

15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid. No Seal
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. No Seal

167ELR-6689-5210

15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. No Seal
15kV, 200 Amp, Straight Plug, Cable Insulation .635-.905 inches, Aluminum Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid. With Jacket Seal.

K151SP-B0240-S

15kV, 200 Amp, Straight Plug, Cable Insulation .635-.905 inches, Aluminum Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid. With Jacket Seal.

Frequently Asked Questions

What is the maximum operating voltage for the 376LR?

The maximum operating voltage is 21.1kV Phase-to-Ground and 36.6kV Phase-to-Phase for 35kV Voltage Class.

What is the voltage and current rating of this elbow connector?

The 376LR Loadbreak Elbow Connector is rated for 35kV voltage class and 200 Amp continuous and loadbreak current.

Does the 376LR elbow connector have a test point?

Yes, the 376LR elbow connector is equipped with an integral, non-corrosive capacitive voltage test point.

What standards does the 376LR elbow connector meet?

The 376LR elbow connector meets ANSI/IEEE Standard 386, Latest Revision.

What items are included in the 376LR elbow connector kit?

Each kit contains an elbow connector housing, a bi-metal compression lug, a probe, a probe wrench, lubricant, installation instructions, and a crimp chart.

What cable insulation diameters are compatible with the 376LR?

The 376LR connects cables with insulation diameters from .850 inches (21.6mm) to 1.465 inches (37.2mm) using four elbow sizes.

What type of conductors are compatible with the compression lugs?

The standard bi-metal compression lug is suitable for copper or aluminum conductors. Copper compression lugs are for copper conductors only.

What standards does the 376LR elbow connector meet?

The 376LR elbow connector meets ANSI/IEEE Standard 386, Latest Revision.

What items are included in the 376LR elbow connector kit?

Each kit contains an elbow connector housing, a bi-metal compression lug, a probe, a probe wrench, lubricant, installation instructions, and a crimp chart.

What type of conductors are compatible with the compression lugs?

The standard bi-metal compression lug is suitable for copper or aluminum conductors. Copper compression lugs are for copper conductors only.

How to Install Elastimold 375LR/376LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of Elastimold 375LR (without test point) and 376LR (with test point) Loadbreak Elbow Connectors on UD cable.

Estimated time: 1h 30m

Tools needed:

Cable cutter, Cable cut back template, Wire brush, Crimp tool, Probe wrench, Cleaning cloths or wipes, Hotstick

Supplies needed:

Elbow Connector Housing (375LR or 376LR), Compression Lug, Probe, Lubricant (supplied, DO NOT SUBSTITUTE), Copper wire (No. 14 AWG / 2.5mm), Grounding connector, UD Cable (concentric neutral, extruded insulation shielding), HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Perform Initial Component Checks and Prepare for Installation

    DANGER: All apparatus must be de-energized during installation. Before starting, check the package contents to ensure they are complete and undamaged. Verify all components fit properly with the cable and/or mating products. Thread the probe into the compression lug to check for resistance; if encountered, replace damaged components. If the product was supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before proceeding.

  2. Prepare the Cable for Training

    Train the UD cable as shown to ease operation, ensuring a minimum of 20 inches beyond the end of the cable pad mount transformer. Cut excess cable squarely at the center line of the bushing.

  3. Prepare the Cable End

    Unwrap and bind concentric neutral wires 8-1/2 inches back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors thoroughly.

  4. Install and Crimp the Compression Lug

    Immediately install the compression lug onto the wire-brushed conductor, rotating it to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  5. Finish Cable Insulation Preparation

    Remove the insulation shield as shown in the template. Bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue, ensuring a straight, smooth, and squared finish without nicks.

  6. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Slide the elbow connector onto the cable with a back-and-forth twisting motion, then wipe off all excess grease. Align the elbow with the compression lug’s threaded hole.

  7. Install and Tighten the Probe

    Thread the probe into the lug by hand, ensuring not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends, indicating proper torque.

  8. Connect the Concentric Neutral Wires

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, providing adequate slack for elbow operation.

  9. Lubricate and Connect the Elbow to the Bushing

    DANGER: Ensure the transformer and elbow are DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches into the bushing, then immediately push the elbow home with a fast, firm, straight motion, applying sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.