Authorized ABB Distributor (Installation Products)
ABB - Installation Products K151SR-C0270 - 15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

ABB Installation Products K151SR-C0270 15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included…

UPC: 783786492145


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SR-C0270 is a 15/25kV 200 Amp deadbreak straight receptacle designed for medium-voltage cable connections in industrial and utility applications. The deadbreak design ensures safe, load-break operations without the need for disconnecting the circuit under full load, reducing downtime and improving safety during maintenance. This receptacle is part of ABB’s Installation Products line, a trusted manufacturer in electrical infrastructure solutions. It is intended for use in switchgear, transformers, and other medium-voltage equipment where reliable, high-amperage connections are critical. Note that bails are required for proper installation but are not included and must be ordered separately. Key applications include utility substations, renewable energy integration, industrial power distribution, and commercial facilities requiring medium-voltage cable terminations. The product’s voltage rating of 15/25kV makes it suitable for systems operating at these levels, while the 200 Amp rating ensures compatibility with high-current circuits. The aluminum compression lug provides a secure, low-resistance connection, minimizing heat generation and ensuring long-term reliability.
  • 15/25kV voltage rating for medium-voltage applications
  • 200 Amp current rating with aluminum compression lug
  • Supports cable insulation diameters from 0.805 inch to 1.060 inch
  • Deadbreak design allows safe load-break operations without full circuit disconnection

Specifications

Amperage Rating
200 A
Application
Designed to connect a cable to another cable or apparatus
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
9.54 in
Length
242.316 mm
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
K151SR
Size
Cable Insulation Diameter 0.805 inch to 1.060 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
2.74 in
Width
69.596 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Cold-Shrinkable Jacket Seal Included.

755LR-K0270-S

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Cold-Shrinkable Jacket Seal Included.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #2 or Solid #1 or mmSquared 33.62.

168ELR-6689-5220

15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #2 or Solid #1 or mmSquared 33.62.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes a copper compression lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SP-B2220

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes a copper compression lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SR-B2220

15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SP-C0220

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

K151SP-C0270

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K151SR-C0250

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

Frequently Asked Questions

What is the primary application of the K151SR receptacle?

The K151SR Straight Receptacle is designed to connect a cable to another cable or apparatus, functioning as a fully shielded, fully submersible, separable insulated connector.

What are the 15kV operating voltage ratings for the K151SR?

For 15kV, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.

What standards does the K151SR receptacle meet?

The K151SR receptacle meets ANSI/IEEE Standard 386, Latest Revision.

What items are included in each K151SR kit?

Each kit contains one straight receptacle housing, one receptacle pin connector, one tube of lubricant, installation instructions, and a crimp chart.

What is the continuous current rating for the K151SR?

The K151SR has a continuous current rating of 200 Amps for both 15kV and 25kV voltage classes.

What are the impulse withstand ratings for 25kV systems?

For 25kV systems, the K151SR has a 125kV BIL Impulse Withstand rating (1.2 x 50 microsecond wave).

What are the 25kV operating voltage ratings for the K151SR?

For 25kV, the maximum phase-to-ground operating voltage is 15.2kV, and the maximum phase-to-phase is 26.3kV.

What are the impulse withstand ratings for 15kV systems?

For 15kV systems, the K151SR has a 95kV BIL Impulse Withstand rating (1.2 x 50 microsecond wave).

What cable types and sizes are compatible with K151SR?

It terminates UD cable with concentric neutral and extruded insulation shielding, and other types with a proper cable shield adapter. It accommodates conductor sizes from No. 4 solid through 4/0 stranded and insulation diameters from .575 in through 1.220 in.

What are the key features of the K151SR receptacle?

It is a 15/25kV, 200 Amp Deadbreak Straight Receptacle with a fully shielded, fully submersible molded rubber housing and provision for ground wire connection.

How to Install the 151SR/K151SR Straight Receptacle

This guide provides step-by-step instructions for installing the 151SR/K151SR Straight Receptacle, designed to connect solid dielectric type cables to other electrical apparatus. It covers cable preparation, crimping, lubrication, and grounding procedures.

Tools needed:

Cable cutting tool, Wire strippers, Wire brush, Crimp tool, Rag, Approved solvent

Supplies needed:

Conductor Contact (male), Nylon Venting Rod, Lubricant (supplied), Crimp Chart, Inhibitor (in crimp barrel), #14 AWG copper wire (or equivalent), Elastimold bail, HV Insulating Plug (K150DP) (if not immediately connecting)

  1. De-energize All Apparatus

    Ensure all electrical apparatus are de-energized before beginning installation or removal of any parts. Follow operating instructions for loadbreak products and adhere to all user, local, and national work rules. Do not touch or move energized products by hand.

  2. Prepare Jacketed Concentric Neutral Cable

    Cut and remove the cable jacket a distance of 8 inches from the cable end. Allow sufficient concentric neutral wires for connecting to the ground point as required by the installation.

  3. Prepare Copper Tape Shield Cable

    Cut and remove the cable jacket a distance of 7 1/2 inches from the cable end. Remove the copper tape shield a distance of 6 1/2 inches from the end of the cable. If using an ECS or MA grounding device, follow its specific instructions regarding outer jacket cut back.

  4. Prepare Conductor Insulation and Shield

    Remove 7/8 inch to 1 inch (or 1 3/4 inches to 1 7/8 inches for #1 stranded/compressed and #1/0 compressed/solid aluminum cable) of cable insulation and conductive shield. Cut squarely, do not pencil. Wire brush bare aluminum conductors and immediately insert them into the crimp barrel which contains inhibitor.

  5. Crimp Socket Terminal

    Crimp the socket terminal onto the bared conductor, ensuring the conductor remains fully seated in the connector. Refer to the crimp chart provided with the contact. Start the crimps at the crimp line imprinted on the crimp barrel and rotate each successive crimp or indent 90 degrees. If using aluminum cable, carefully wipe excess inhibitor from the contact and cable insulation.

  6. Prepare Semi-Conductive Shield and Clean Insulation

    Remove the semi-conductive shield to a point 7 9/16 inches to 7 5/8 inches back from the end of the pin with a straight, smooth, 'squared' cut. Do not cut or nick the insulation. Pencil insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation with an approved solvent, wiping from the end of the cable toward the outer jacket, to remove all traces of semi-conducting residue. If using an ECS or MA grounding device, install it following its appropriate installation instructions.

  7. Lubricate Receptacle and Cable

    Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable as shown in the diagram and to the inside of the housing. DO NOT SUBSTITUTE other lubricants, as they may be harmful to this product or its mating product.

  8. Insert Cable into Receptacle Housing

    Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. IMPORTANT: If the receptacle is not to be immediately connected, replace the protective cover with an appropriate HV insulating plug (e.g., K150DP), as the shipping cover only offers protection from dirt and is not an insulating device.

  9. Connect to Mating Plug

    Lubricate the nose of the mating plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), taking care not to cut the rod. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with an Elastimold bail.

  10. Ground the Cable

    If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly. Connect the grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.