ABB Installation Products 162LR-B2230-SG3 15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable…
UPC: 075114331876
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV, 200 Amp rated loadbreak elbow connector for medium-voltage applications
- Integrated test point for safe system diagnostics without de-energizing circuits
- Accommodates cable insulation diameters from 0.635" to 0.905"
- Supports #1 Stranded/Compressed or 1/0 Solid/Compact conductor sizes
- Includes cold shrinkable sealing kit with copper braid and constant force spring for environmental protection
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 15kV class, 200 Amp Distribution Apparatus |
Color | Black |
Conductor Range | #1 STR/COMPR AWG , 1/0 SOL/COMPT AWG |
Connection Type | Loadbreak |
Connection Type | Compression Lug |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Material | Copper, Cold Shrinkable Seal |
Material | Copper |
Series | 162LR |
Size | .635 inch - .905 inch Cable Insulation Diameter |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation, Provision for ground wire connection. Non-Corrosive Capacitive Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

162LR-B-2230
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #1 Stranded Wire Size, Copper Compression Lug
K655DLR-K0270-SG3
15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.090-1.310 inches, Aluminum Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Solid/Compact. Sealing Kit - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
K655DLR-L0240-S
15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.180-1.465 inches, Aluminum Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact. Sealing Kit - Cold Shrinkable Jacket Seal.
K655DLR-J0300-SG3
15/25kv, 600 Amps, Deadbreak Direct Test Elbow without Test Point. With Cold-Shrinkable Jacket with Copper Braid and Constant Force Spring. Universal Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 Compacted, Solid 400.
K655DLR-H0270-SG3
15/25kv, 600 Amps, Deadbreak Direct Test Elbow without Test Point. With Cold-Shrinkable Jacket with Copper Braid and Constant Force Spring. Universal Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 Compacted, Solid 250.
K655DLR-LM0300-SG3
15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.280-1.430 inches, Aluminum Compression Lug, Conductor Size 350 Stranded/Compressed or 400 Solid/Compact. Sealing Kit - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.Frequently Asked Questions
What material is used for the pulling eye?
The pulling eye is made of robust stainless steel, designed to promote durable hotstick control.
What is the function of the internal probe support?
The internal rigid probe support ensures proper switching and facilitates easy probe installation.
Does the elbow have a no-stick interface?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
Is the Elastimold elbow suitable for rural infrastructure?
Yes, it has Rural Utilities Service (RUS) acceptance, authorizing its use in rural infrastructure construction and improvements.
What standards and certifications does it meet?
The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.
What safety features does the elbow include?
It has improved insulation for 15 kV, rigid probe support, a no-stick interface, a robust stainless-steel pulling eye, and dual grounding eye positions.
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced loadbreak elbow for 15 kV and 25 kV series, incorporating over 50 years of innovative design and manufacturing experience.
What material is used for the pulling eye?
The pulling eye is made of robust stainless steel, designed to promote durable hotstick control.
What is the function of the internal probe support?
The internal rigid probe support ensures proper switching and facilitates easy probe installation.
Does the elbow have a no-stick interface?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
How to Install the 162LR Loadbreak Elbow Connector
This guide provides step-by-step instructions for the safe and proper installation of the 162LR Loadbreak Elbow Connector, including detailed cable preparation, assembly, and grounding procedures. DANGER: All apparatus must be de-energized during installation.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Cable cutting tools, Wire brush, Crimp tool, Probe wrench, Hotstick, Suitable sensing device for capacitive test points, Vinyl tape
Supplies needed:
162LR Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, do not substitute), UD Cable (appropriate type), Copper wire (No. 14 AWG / 2.5mm) or equivalent, Appropriate connector for neutral wires, Cold shrink tube (if using sealing kit), Conductive copper tape (if using sealing kit), Silicone lubricant (for test point cap)
- Prepare Cable for Termination
Train the cable to ensure adequate slack for operation. Based on your specific cable type (non-jacketed concentric neutral, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), prepare the neutral or ground wires and cut the cable squarely at the bushing centerline. Remove the outer jacket and/or copper tape shield to the specified lengths (e.g., 9-5/8” for jacket, 7-1/8” for copper tape shield). If applicable, slide the cold shrink tube onto the cable and secure copper tape shields.
- Prepare Conductor and Insulation
Remove the shield and insulation 2-1/8” (55mm) from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug. Rotate the lug to spread inhibitor and align its threaded hole with the bushing bore. Crimp according to the lug's chart, rotating 180 degrees for successive crimps. Wipe off excess inhibitor. Remove the insulation shield 6-7/8” (175mm) from the lug end. Bevel the insulation end 1/8” (5mm) maximum, ensuring the cut is straight, smooth, and squared. Thoroughly clean the insulation.
- Assemble Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Keep insulation clean. Slide the elbow connector onto the cable with a back-and-forth twisting motion and wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten with the supplied wrench until the wrench bends.
- Ground the Elbow and Neutral Wires
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow. Twist tightly, taking care not to damage the eye. Twist all neutral wires and connect them to ground using an appropriate connector, providing adequate slack for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions to complete the installation.
- Connect Elbow to Bushing Plug
DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant; only lubricate if known to be de-energized. Operate the elbow using a full insulated hotstick tool; DO NOT OPERATE BY HAND. Insert the probe tip approximately 2” (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock.
- Perform Voltage Test (162LR Only)
Remove the test point cap with a hotstick, peeling off at an angle. WARNING: The voltage test point is a capacitance device; it is not directly connected to the conductor. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Do not use conventional voltage measuring equipment. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means, as contamination or incorrect equipment can provide a false reading. After testing, clean the inside surface of the cap, lubricate with silicone lubricant, and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.