Authorized ABB Distributor (Installation Products)
ABB - Installation Products K151SR-A0210 - 15/25kV 200 Amp, Deadbreak Straight Receptacle, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size #3 Compressed or Stranded AWG, or #2 Solid or Compact AWG or 26.67 mm2. Bails are required, but not included, order separately. Length 9.54 inch. Widest point 2.74 inch.

ABB Installation Products K151SR-A0210 15/25kV 200 Amp, Deadbreak Straight Receptacle, Cable Insulation Diameter 0.575 inch to…

UPC: 075114403795


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SR-A0210 is a 15/25 kV, 200 Amp deadbreak straight receptacle designed for medium-voltage cable terminations. This unit features an aluminum compression lug suitable for conductors ranging from #3 compressed or stranded AWG, or #2 solid or compact AWG (equivalent to 26.67 mm²). It accommodates cable insulation diameters between 0.575 and 0.740 inches. The receptacle has a length of 9.54 inches and a widest point of 2.74 inches. Bails are required for installation and must be ordered separately. This deadbreak receptacle is engineered for reliable performance in underground distribution systems, switchgear, and pad-mounted transformers, providing secure, high-amperage connections in demanding electrical applications. Its construction and specifications align with industry requirements for medium-voltage power systems.
  • 15/25 kV voltage rating
  • 200 Amp current rating
  • Aluminum compression lug
  • Accommodates #3/#2 AWG conductors
  • 0.575 - 0.740 inch cable insulation diameter

Specifications

Amperage Rating
200 A
Application
Designed to connect a cable to another cable or apparatus
Color
Black
Conductor Range
#3 STR/COMPR AWG , #2 SOL/COMPT AWG
Connection
Compression
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
9.54 in
Length
242.316 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Width
2.74 in
Width
69.596 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2 AWG Solid/Compact.

168FLR1-C0210

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2 AWG Solid/Compact.
Tin Plated Aluminum Mechanical Streetlight kit. Feeder 2/0 - #14, #14 - #6. Connector Length 1-15/64 inch x 3/4 inch x 1-1/8 inch. Includes (4) Screws - 5/16-24.

SL 210-6

Tin Plated Aluminum Mechanical Streetlight kit. Feeder 2/0 - #14, #14 - #6. Connector Length 1-15/64 inch x 3/4 inch x 1-1/8 inch. Includes (4) Screws - 5/16-24.
Aluminum Compression StreetLight Kit, Run #8-#6 Aluminum, Tap #8-#6 Aluminum. Includes Insulating Cap and Rocket, Wood Dowel, (2) Tin Plated Fuse Clips, Instruction Sheet and Silicone Grease.

SLK 3 A

Aluminum Compression StreetLight Kit, Run #8-#6 Aluminum, Tap #8-#6 Aluminum. Includes Insulating Cap and Rocket, Wood Dowel, (2) Tin Plated Fuse Clips, Instruction Sheet and Silicone Grease.
Flood Seal In Line Disconnect Kit, Single Housing. Includes Santoprene Insulating Cap and Rocket, Wood Dowel, (2) Tin Plated Copper Fuse Clips, (2) Copper Wire Stranded #14 x 19-3/4 inch, Silicone Grease.

SLK 6-8488

Flood Seal In Line Disconnect Kit, Single Housing. Includes Santoprene Insulating Cap and Rocket, Wood Dowel, (2) Tin Plated Copper Fuse Clips, (2) Copper Wire Stranded #14 x 19-3/4 inch, Silicone Grease.
Aluminum Mechanical Streetlight kit. Includes (2) Insulating Rockets trimmed at #14 - #10 Ring, (2) Fuse Clips, (1) Line End, (1) Load End, (2) #2 - #14 Wire Ends with Screws - 5/16-24 x 3/8 inch, Silicone Grease and Installation Instructions.

SLK 22 M 10 CAB

Aluminum Mechanical Streetlight kit. Includes (2) Insulating Rockets trimmed at #14 - #10 Ring, (2) Fuse Clips, (1) Line End, (1) Load End, (2) #2 - #14 Wire Ends with Screws - 5/16-24 x 3/8 inch, Silicone Grease and Installation Instructions.
Mechanical Fuse Kit Inline, Includes EPDM Rubber Finished Rocket and Twin Cap, Silicone Grease, Copper Wire #10,7 X 37/34. One Tin Plated Copper Fuse Holder with 5/16-24 Aluminum Set Screw with 1/8 Hex, One Tin Plated Aluminum Mechanical Splice with Three Stainless Steel 1/4-28 x 3/8 inch Screws. Accepts Standard Non-Glass Type Cartridge Fuse with 13/32 inch Diameter and 1-1/2 inch Length. Wire Range #12 to #4 CU-AL AWG.

SLK-YM

Mechanical Fuse Kit Inline, Includes EPDM Rubber Finished Rocket and Twin Cap, Silicone Grease, Copper Wire #10,7 X 37/34. One Tin Plated Copper Fuse Holder with 5/16-24 Aluminum Set Screw with 1/8 Hex, One Tin Plated Aluminum Mechanical Splice with Three Stainless Steel 1/4-28 x 3/8 inch Screws. Accepts Standard Non-Glass Type Cartridge Fuse with 13/32 inch Diameter and 1-1/2 inch Length. Wire Range #12 to #4 CU-AL AWG.
Tin Plated Aluminum Mechanical Streetlight kit, Run #10 - #4 Aluminum and Copper, Tap #10 - #4 Aluminum and Copper. Includes Insulating Cap and Rocket, Wood Dowel, (2) Tin Plated Aluminum Fuse Clips with Screws, Silicone Grease and Instruction Sheet

SLK 60 M

Tin Plated Aluminum Mechanical Streetlight kit, Run #10 - #4 Aluminum and Copper, Tap #10 - #4 Aluminum and Copper. Includes Insulating Cap and Rocket, Wood Dowel, (2) Tin Plated Aluminum Fuse Clips with Screws, Silicone Grease and Instruction Sheet
Flood Seal, YY Type Fused Disconnect StreetLight Kit, #14-#4 Copper, #14-#2 Aluminum includes Insulating Twin Cap and Twin Rocket, Fuse Clip, Copper Wire 10 Gauge, (3) Screws, Silicone Grease, Oxide Inhibitor, Instruction Sheet

YFU

Flood Seal, YY Type Fused Disconnect StreetLight Kit, #14-#4 Copper, #14-#2 Aluminum includes Insulating Twin Cap and Twin Rocket, Fuse Clip, Copper Wire 10 Gauge, (3) Screws, Silicone Grease, Oxide Inhibitor, Instruction Sheet

Frequently Asked Questions

Are bails included with the K151SR-A0210?

No, bails are required for installation but must be ordered separately.

What material is the compression lug made of?

The compression lug is made of aluminum.

What voltage rating does this receptacle support?

The K151SR-A0210 supports 15/25kV medium-voltage applications.

What is the maximum cable insulation diameter?

The maximum cable insulation diameter is 0.740 inches.

What is the physical length of the receptacle?

The receptacle measures 9.54 inches in length.

What is the widest point of the device?

The widest point of the K151SR-A0210 is 2.74 inches.

What conductor sizes are compatible with this receptacle?

The unit accepts #3 compressed or stranded AWG, or #2 solid or compact AWG conductors (26.67 mm²).

How to Install the 151SR/K151SR Straight Receptacle

This guide provides step-by-step instructions for installing the 151SR/K151SR Straight Receptacle, designed to connect solid dielectric type cables to other electrical apparatus or cables. Ensure all apparatus are de-energized and installation is performed by competent personnel trained in high voltage safety practices.

Estimated time: 45m

Tools needed:

Cable cutting tool, Wire strippers, Wire brush, Crimping tool, Rag

Supplies needed:

151SR/K151SR Straight Receptacle, Conductor Contact (male), Nylon Venting Rod, Lubricant (supplied with product), Solid dielectric type cable (15kV or 25kV class), Approved solvent, Elastimold bail, #14 AWG copper wire (or equivalent, for grounding), Silicone grease (for mating plug)

  1. Prepare Cable Jacket

    For Jacketed Concentric Neutral cable, cut and remove the cable jacket 8 inches from the cable end, ensuring sufficient concentric neutral wires for grounding. For Copper Tape Shield cable, cut and remove the cable jacket 7 1/2 inches from the cable end, then remove the copper tape shield 6 1/2 inches from the cable end. If using an ECS or MA grounding device, follow its specific installation instructions for outer jacket cut back.

  2. Prepare Cable Insulation and Conductor

    Remove 7/8 to 1 inch (or 1 3/4 to 1 7/8 inches for #1 stranded/compressed and #1/0 compressed/solid aluminum cable) of cable insulation and conductive shield. Cut squarely, do not pencil. Wire brush bare aluminum conductors and immediately insert them into the crimp barrel, which contains inhibitor.

  3. Crimp Conductor Contact

    Crimp the socket terminal onto the bared conductor, ensuring the conductor remains fully seated in the connector. Start the crimps at the crimp line imprinted on the barrel and rotate each successive crimp or indent 90 degrees. When using aluminum cable, carefully wipe excess inhibitor from the contact and cable insulation.

  4. Prepare and Clean Insulation

    Remove the semi-conductive shield to a point 7 9/16 to 7 5/8 inches back from the end of the pin with a straight, smooth, squared cut, taking care not to cut or nick the insulation. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation to remove all traces of semi-conducting residue by wiping with an approved solvent from the end of the cable toward the outer jacket. If using an ECS or MA grounding device, install it following its appropriate instructions.

  5. Lubricate Cable and Receptacle

    Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable as shown and to the inside of the housing. Do not substitute other lubricants, as they may be harmful to this product or its mating product.

  6. Insert Cable into Receptacle

    Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. Important: If the receptacle is not to be immediately connected, replace the protective cover. Note that the shipping cover offers protection from dirt only and is not an insulating device; obtain an Elastimold insulating plug (K150DP) if an insulating device is required.

  7. Connect to Mating Plug

    To connect to a mating plug, first lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), ensuring the rod is not cut. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with the aid of an Elastimold bail.

  8. Ground the Cable

    If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly. Then, connect the grounding assembly of the connector to the system ground by merging with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.