ABB Installation Products K151-SR-A0200 15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included…
UPC: 783786505081
Contact for Pricing
Minimum Qty: 30
Multiplier: 30
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25kV voltage rating
- 200 Amp continuous current rating
- Accommodates cable insulation diameters from 0.575" to 0.740"
- Aluminum compression lug for secure conductor termination
- Supports stranded AWG #4 / solid AWG #3 / 21.14 mm² conductors
Specifications
Amperage Rating | 200 A |
Application | Designed to connect a cable to another cable or apparatus |
Color | Black |
Conductor Range | #4 STR/COMPR AWG , #3 SOL/COMPT AWG |
Connection | Compression |
Connection Type | Deadbreak Straight Receptacle |
Current Rating | 200 A |
Environmental Conditions | Fully Shielded, Fully Submersible |
Insulation | True |
Length | 9.54 in |
Length | 242.316 mm |
Material | Aluminum |
Material | Housing - EPDM-Rubber |
Poles | 1 |
Series | K151-SR |
Size | Cable Insulation Diameter 0.575 to 0.740 inches |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Straight Receptacle |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15/25 kV |
Width | 2.74 in |
Width | 69.596 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

168FLR1C5200-S
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Crimp Connector, Conductor size #4 Stranded/Compressed or #3 Solid/Compact. S - Cold-Shrinkable Jacket Seal.
K152SR-D0270
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle with Test Point, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
K655YSR-M2400
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.
K656CH-K0320
600 Amp, 15/25kV, Separable H Joint Kit, 4-Way with Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.
K152SR-B2240
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle with Test Point, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
K656CH-DP0593493
25kv Compact H Joint Kit with two Cable Insulation Diameters size M - 1.370 to 1.630 with Aluminum Lugs for 750 kcmil, and two Cable Insulation Diameters size L - 1.180 to 1.465 with Aluminum Lugs for 500 kcmil, includes Cold-Shrinkable Seal with Copper Rod and Crimp Connector.
K656CY-M0360-SG1
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400. Cold Shrinkable Seal with Copper Rod and Crimp Connector Included.
K675SR-K2360-SG2
900 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400. Cold Shrinkable Seal with Copper Rod and Constant Force Spring Included.Frequently Asked Questions
What is the K151SR Straight Receptacle used for?
It is a fully shielded, fully submersible, separable insulated connector designed to connect a cable to another cable or apparatus.
What voltage systems is the K151SR suitable for?
The K151SR is suitable for use on both 15kV and 25kV systems.
What is the continuous current rating of the K151SR?
The K151SR has a continuous current rating of 200 Amps for both 15kV and 25kV voltage classes.
What conductor sizes can the K151SR accommodate?
It can accommodate conductor sizes from No. 4 solid through 4/0 stranded.
What cable insulation diameters does the K151SR support?
The K151SR supports cable insulation diameters ranging from 0.575 inches through 1.220 inches.
When can the K151SR's disconnectible feature be used?
The disconnectible feature of the K151SR can only be used when the circuit is de-energized.
When can the K151SR's disconnectible feature be used?
The disconnectible feature of the K151SR can only be used when the circuit is de-energized.
What cable insulation diameters does the K151SR support?
The K151SR supports cable insulation diameters ranging from 0.575 inches through 1.220 inches.
What conductor sizes can the K151SR accommodate?
It can accommodate conductor sizes from No. 4 solid through 4/0 stranded.
What is the continuous current rating of the K151SR?
The K151SR has a continuous current rating of 200 Amps for both 15kV and 25kV voltage classes.
How to Install the Elastimold 151SR/K151SR Straight Receptacle
This guide provides detailed instructions for preparing the cable, installing the conductor contact, and connecting the Elastimold 151SR/K151SR Straight Receptacle to a mating product and system ground. Ensure all apparatus are de-energized before starting.
Estimated time: 1h
Tools needed:
Wire brush, Crimping tool, Rag, Approved solvent
Supplies needed:
Elastimold 151SR/K151SR Straight Receptacle, Conductor Contact (male), Nylon Venting Rod, Lubricant, Crimp Chart, Solid dielectric type cable, Copper wire (#14 AWG or equivalent), Elastimold bail, Silicone grease (for mating plug), Elastimold insulating plug (K150DP) (optional)
- Initial Safety and Inspection
DANGER: All apparatus must be de-energized during installation or removal of parts. Inspect all components for damage, proper rating, and compatibility with mating parts. This product should only be installed by competent personnel trained in good safety practices involving high voltage electrical equipment.
- Prepare Cable Jacket
For jacketed concentric neutral cable, cut and remove 8 inches of cable jacket from the end, ensuring sufficient neutral wires for grounding. For copper tape shield cable, cut and remove 7.5 inches of cable jacket, then remove the copper tape shield 6.5 inches from the cable end.
- Prepare Conductor and Crimp
Remove 7/8 to 1 inch of cable insulation and conductive shield (1 3/4 to 1 7/8 inches for #1 stranded/compr. and #1/0 comp./solid aluminum cable). Wire brush bare aluminum conductors and immediately insert them into the crimp barrel which contains inhibitor. Cut squarely, do not pencil.
- Crimp Socket Terminal
Crimp the socket terminal onto the bared conductor, ensuring the conductor remains fully seated in the connector. Refer to the crimp chart. Start crimps at the imprinted crimp line and rotate each successive crimp or indent 90 degrees. If using aluminum cable, carefully wipe excess inhibitor from the contact and cable insulation.
- Prepare and Clean Insulation
Remove the semi-conductive shield to a point 7 9/16 to 7 5/8 inches back from the end of the pin with a straight, smooth, 'squared' cut. DO NOT CUT OR NICK THE INSULATION. Pencil insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation to remove all traces of semi-conducting residue by wiping with an approved solvent from the cable end toward the outer jacket.
- Lubricate Receptacle and Cable
Remove the protective cap from the straight receptacle. Keep cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable as shown and to the inside of the housing. DO NOT SUBSTITUTE, as other lubricants may be harmful to this product or its mating product.
- Insert Cable into Receptacle
Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. IMPORTANT: If the receptacle is not to be immediately connected, replace the protective cover. The shipping cover offers protection from dirt only and is not an insulating device; obtain an Elastimold insulating plug (K150DP) if insulation is required.
- Connect to Mating Plug
Lubricate the nose of the mating plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches). Carefully insert the plug assembly into the receptacle as far as possible, then pull out the nylon rod. Secure the electrical connection with an Elastimold bail.
- Ground the Cable
If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly. Connect this grounding assembly to the system ground by merging with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.