Authorized ABB Distributor (Installation Products)
ABB - Installation Products K152SR-D0270 - 200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle with Test Point, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

ABB Installation Products K152SR-D0270 200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle with Test Point, Bails are…

UPC: 783786515486


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K152SR-D0270 is a 200 Amp, 15/25kV deadbreak elbow, designed as a straight receptacle for reliable electrical connections. This component is part of ABB's Installation Products catalog, identified by SKU K152SR-D0270. It features a test point for diagnostic capabilities, crucial for maintaining system integrity and troubleshooting. The deadbreak elbow is engineered to accommodate cable insulation diameters ranging from 0.890 inches to 1.220 inches, ensuring compatibility with a variety of medium-voltage cables. It utilizes an aluminum compression lug for secure conductor termination. This lug is rated for compressed stranded conductors of 4/0 AWG and solid conductors of 250 AWG (or 126.67 mm²). Please note that bails are required for proper installation and must be ordered separately. This product is suitable for applications requiring a robust and dependable connection in medium-voltage power distribution systems. Its construction and ratings are designed for operational efficiency and safety.
  • 200 Amp, 15/25kV rating for medium-voltage applications
  • Straight receptacle design for direct connections
  • Integrated test point for diagnostic access
  • Accommodates cable insulation diameters from 0.890" to 1.220"
  • Aluminum compression lug for 4/0 AWG stranded or 250 AWG solid conductors

Specifications

Amperage Rating
200 A
Application
Designed to connect a cable to another cable or apparatus
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection
Compression
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
K152SR
Size
Cable Insulation Diameter 0.890 inch to 1.220 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle with Test Point
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Compacted Solid 250 kcmil or mmSquared Compact 125.

K655SR-J0270

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Compacted Solid 250 kcmil or mmSquared Compact 125.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.

K655YSR-M2400

600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.
600 Amp, 15/25kV, Separable H Joint Kit, 4-Way with Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.

K656CH-K0320

600 Amp, 15/25kV, Separable H Joint Kit, 4-Way with Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle with Test Point, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K152SR-B2240

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle with Test Point, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
25kv Compact H Joint Kit with two Cable Insulation Diameters size M - 1.370 to 1.630 with Aluminum Lugs for 750 kcmil, and two Cable Insulation Diameters size L - 1.180 to 1.465 with Aluminum Lugs for 500 kcmil, includes Cold-Shrinkable Seal with Copper Rod and Crimp Connector.

K656CH-DP0593493

25kv Compact H Joint Kit with two Cable Insulation Diameters size M - 1.370 to 1.630 with Aluminum Lugs for 750 kcmil, and two Cable Insulation Diameters size L - 1.180 to 1.465 with Aluminum Lugs for 500 kcmil, includes Cold-Shrinkable Seal with Copper Rod and Crimp Connector.
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400. Cold Shrinkable Seal with Copper Rod and Crimp Connector Included.

K656CY-M0360-SG1

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400. Cold Shrinkable Seal with Copper Rod and Crimp Connector Included.
900 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400. Cold Shrinkable Seal with Copper Rod and Constant Force Spring Included.

K675SR-K2360-SG2

900 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400. Cold Shrinkable Seal with Copper Rod and Constant Force Spring Included.

Frequently Asked Questions

What is the K152SR Straight Receptacle?

It is a fully shielded, fully submersible, separable insulated connector designed to connect a cable to another cable or apparatus.

What conductor sizes can the K152SR accommodate?

It accommodates conductor sizes from No. 4 solid through 4/0 stranded.

What type of cable is the K152SR designed for?

It is designed to terminate UD cable with concentric neutral and extruded insulation shielding. It can also terminate other types of cable with a proper adapter.

What cable insulation diameters does the K152SR support?

The K152SR supports cable insulation diameters from .575 inches through 1.220 inches.

What other Elastimold products can the K152SR mate with?

The K152SR is designed to mate with the K150T tee splice and the K151SP straight plug.

What is the impulse withstand rating (BIL) for the K152SR?

The impulse withstand (BIL) rating is 125kV.

What is the AC one-minute withstand voltage?

The AC one-minute withstand voltage is 40kV.

What is the continuous current rating of the K152SR?

The continuous current rating for the K152SR is 200 Amps.

What is the maximum operating voltage for the K152SR?

The maximum phase-to-ground operating voltage is 15.2kV, and the maximum phase-to-phase voltage is 26.3kV.

What materials are used in the K152SR construction?

It features 100% peroxide-cured construction, including insulation and conductive EPDM materials, within a molded rubber housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.