Overview
- Y-Type fuse and disconnect kit for street/highway lighting systems
- Supports stranded copper conductors: 4 AWG (run/tap), 1/0 AWG, and 14 AWG
- Includes crimped lug connectors and installation dies (5/16, 8, TP, 29)
- 600V rated with Flood-Seal design for environmental resistance
- Load-end twin cap assembly with silicone grease application for corrosion protection
Specifications
Amperage Rating | 30 A |
Application | Rated 600V, 30 Amps Maximum, perfect for heavy-duty applications |
Color | Black |
Conductor Range | #4 STR AWG |
Connection | Compression |
Connection Type | Crimped Lug |
Connection Type | Crimped Lug Connectors |
Environmental Conditions | WaterTight |
Insulation | True |
Length | 9-3/4 in |
Material | Aluminum and Copper, EPDM-Rubber Housing |
Material | Copper |
Number of Conductors | 3 |
Series | Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type |
Series | Flood-Seal |
Size | 4 AWG |
Special Features | EPDM Flood-Seal Housing ensures a fully insulated, watertight, and submersible connection. Safe separations to ensure fuse or connecting link stays in load side when separated. Dual-Rated. Approved for a wide range of aluminum or copper connections |
Type | Break-Away Streetlight Kits |
Voltage Rating | 600V |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.5200 L |
Package Weight (Metric) | 0.2360 kg |

FYA 4
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, fused, wire size stranded 4, aluminum run copper tap fused, installing dies 52,BG,243,5/8
FYC 2/0
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, fused, wire size stranded 2/0, copper run ,copper tap fused, installing dies 9/16,13,TS,45
FYC 6
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, fused, wire size stranded 6 ,copper run, copper tap fused, installing dies J,7,TE,24
FYC 1/0
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, fused, wire size stranded 1/0, copper run ,copper tap fused, installing dies 1/2,12,TQ,42
FYC 1
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, fused, wire size stranded 1 copper run ,copper tap fused, installing dies 3/8,11K,TB,37
FYC 2
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits Y-Type with Crimped Lug Connectors, fused, wire size stranded 2, copper run, copper tap fused, installing dies 3/8,10,TL-TN,33How to Install the FYC/DYC Copper Street Lighting Kit
This guide provides step-by-step instructions for the assembly and wiring of the FYC/DYC copper street lighting kit. Ensure power is disconnected and identify LINE/LOAD sides before beginning. Installation must be performed by a qualified electrician in accordance with national and local electrical codes.
Estimated time: 1h
Tools needed:
Measuring tool (for cable diameter), Cutting tool, Wire strippers, Crimping tool (refer to Table 2 in documentation), Wood dowel (assembly dowel), Screwdriver, Wire brush (for aluminum conductors only)
Supplies needed:
Y-Type housing, Load side (Plug) housing, Line end insert, Fuse holder, Connecting link (DYA & DYC only), Fuse (13/32" x 1 1/2", 600V 30A max, NOT glass body), 1 Nut, 1 Bolt, 2 Belleville washers & 2 Lugs, Lubricant, Electrical cable (load side and run connection), HM53 inhibitor or equivalent (for aluminum conductors only)
- Prepare Load Side Housing
Measure the cable diameter. Refer to Table 1 in the documentation to select the corresponding section on the load side (plug) housing. Cut off any remaining sections of the housing to the size referenced in the Range column of Table 1. This ensures a proper fit for your cable.
- Prepare Load Side Cable
Thoroughly clean approximately 8 inches along the load side cable end. Apply lubricant and insert the cable through the small hole in the load side (plug) housing. Push the cable through a sufficient distance to permit 3/8 inch for stripping of insulation. Strip insulation a distance of 3/8 inch as shown in the product illustration. CAUTION: Do not over strip the cable insulation.
- Crimp Fuse Holder to Cable
Insert the stripped cable end into the crimp barrel of the fuse holder. Crimp the fuse holder securely using a suitable crimping tool and die. Refer to Table 2 in the documentation for suggested tools and dies based on your conductor size.
- Assemble Load Side Housing with Fuse Holder
Apply lubricant lightly to the outside of the fuse holder. Place the wood dowel into the fuse holder socket and position the free end of the dowel against a firm surface. Push the load side (plug) housing forward until the fuse holder snaps into its locked position. Wipe off any excess lubricant after assembly.
- Insert Fuse or Connecting Link
Insert a 13/32 inch by 1 1/2 inch fuse (600 Volt 30 Amp maximum) or the connecting link (if applicable for DYA & DYC models) into the load side (plug) housing. WARNING: DO NOT use a glass body fuse, as this can pose a safety risk.
- Prepare Y-Type Housing and Run Connection Cable
For the run connection, select and cut the correct cut-off ring on the Y-Type housing that matches the cable being used. Cut and bevel the cable insulation. Apply lubricant to the end of the cable and the cut opening of the Y-Type housing. Slide the cable through until it extends 2 to 3 inches beyond the housing, as shown in Figure A. Strip the cable insulation to fit the compression lugs, as shown in Figure B.
- Crimp Lugs to Cable
Crimp the lugs onto the prepared cable ends using the proper crimping tool. Ensure that the pad portions of the lugs are positioned back to back. For aluminum conductors only: Wire brush the pads of the lugs, then apply HM53 inhibitor or an equivalent product on the pads, and finally wipe off any excess inhibitor.
- Assemble Line End Insert Components
Assemble the line end insert components as shown in the product illustration. Carefully tighten the bolted assembly, which includes the nut, bolt, Belleville washers, and lugs, to ensure a secure connection.
- Assemble Line End Insert into Y-Type Housing
Apply lubricant to the relevant surfaces as indicated in the illustration. Slide the Y-Type housing up to the bottom of the line end insert. Push the line end insert firmly into the opening of the Y-Type housing. While pulling on the cables and holding onto the Y-Type housing, slide the housing toward the line end insert. Continue to push the line end insert until it is fully seated and locked into the Y-Type housing.
- Connect Load Side to Line End
Lubricate both the male and female components of the connection. Carefully insert the load side (plug) housing, which contains the installed link or fuse clip, into the line end insert. Ensure a firm and complete connection.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.