ABB - Installation Products 756LR-N2330 - 35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

ABB Installation Products 756LR-N2330 35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and…

UPC: 783786024674


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 756LR-N2330 is a 35kV 600 Series Deadbreak Elbow connector designed for reliable electrical connections in medium voltage applications. This unit features a test point for safe and convenient testing of the circuit. It includes an insulated plug, cap, stud, lug, and cable adapter for a complete connection solution. The included copper compression lug ensures a secure and durable connection to the conductor. Designed for cable insulation diameters ranging from 1.515 inches to 1.780 inches, this elbow accommodates a variety of cable sizes. It supports conductor sizes including compressed stranded 500 kcmil, compacted solid 600 kcmil, and mmSquared compact conductors of 250/300. The 600 Series deadbreak design provides a fully shielded, submersible connection, crucial for underground and pad-mounted transformer applications. Manufacturer: ABB - Installation Products. SKU: 756LR-N2330. UNSPSC Code: 39121421.
  • 35kV voltage rating for medium voltage systems
  • 600A continuous current rating
  • Integrated test point for circuit testing
  • Accommodates cable insulation diameters from 1.515" to 1.780"
  • Supports conductor sizes: 500 kcmil (stranded), 600 kcmil (solid), 250/300 mm² (compact)

Specifications

Amperage Rating
600 A
Application
35 kv, 600 Amp
Color
Black
Conductor Range
500 kcmil , 600 kcmil
Connection
Compression
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Special Features
35kV, 600 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Width
12.28 in
Width
311.912 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
8.6500 L
Package Weight (Metric)
3.9240 kg
600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

755LRTP-M0330-DRG

600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.

776LR-L5270-S

900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

756LR-N0330

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. Cold-Shrinkable Jacket Seal Included.

756LR-P0410-S

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. Cold-Shrinkable Jacket Seal Included.
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. Cold-Shrinkable Jacket Seal Included.

776LR-J5240-S

900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. Cold-Shrinkable Jacket Seal Included.
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included. Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

776LR-P2380-SG3

900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included. Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 600 /Compacted Solid 600.

756LR-N0350

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 600 /Compacted Solid 600.
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.725 inch to 1.935 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. Cold-Shrinkable Jacket Seal Included.

776LR-P5410-S

900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.725 inch to 1.935 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. Cold-Shrinkable Jacket Seal Included.

Frequently Asked Questions

What is the primary application of the 756LR elbow?

It provides fully shielded, dead-front submersible cable connections to high-voltage apparatus.

Is the 756LR elbow suitable for submersible applications?

Yes, the 756LR features a fully shielded, fully submersible molded rubber housing.

What accessories are available for the 756LR?

Optional accessories allow for external separation, by-pass, isolation, grounding, testing, and adding taps or surge arrestors.

What is recommended for metallic tape shield cables?

For metallic tape shield or drain wire cable, an ECS cable seal grounding device is recommended.

What materials are used in the 756LR's construction?

It features 100% peroxide-cured construction, including insulation and conductive EPDM materials.

What standard does the 756LR elbow meet?

The 756LR elbow meets ANSI/IEEE Standard 386, Latest Revision.

What cable insulation diameters does the 756LR support?

The 756LR supports cable insulation diameters ranging from 0.760 inches to 2.120 inches.

What conductor sizes are compatible with the 756LR?

It is compatible with conductor sizes from #2 AWG to 1250 kcmil for aluminum and copper conductors.

What is the continuous current rating of the 756LR?

The 756LR elbow has a continuous current rating of 600 Amps.

What is the maximum operating phase-to-ground voltage?

The maximum phase-to-ground operating voltage for the 756LR is 21.1kV.

How to Install 756LR/776LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 756LR and 776LR deadbreak elbow connectors on 35kV class systems, including cable preparation, crimping, and connection to mating apparatus.

Estimated time: 2h

Tools needed:

Wire strippers, Crimping tool, Wire brush (for aluminum conductors), Hotstick, Suitable voltage sensing device, Torque wrench

Supplies needed:

756LR or 776LR Elbow Connector kit (includes Elbow, Cable Adapter, Compression Lug, Insulating Plug, Crimp connector, Lubricant, Stud Prepack), Wire (at least No. 14 AWG Copper for grounding), Suitable ground connector, HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Prepare for Installation and Ensure Safety

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products in the work area. Failure to follow these instructions will result in serious or fatal injury. Inspect all kit contents for completeness and damage. Verify all components are compatible with the cable and mating products. Read all instructions thoroughly before beginning and ensure all required tools are at hand. Maintain cleanliness throughout the procedure.

  2. Position and Cut the Cable

    Position the cable in its final assembled location, ensuring enough slack for adequate clearance to remove the elbows. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.

  3. Clean the Cable Outer Jacket

    Clean the outer jacket of the cable for a distance of 24 inches (610mm) from the cut end.

  4. Prepare the Cable Insulation and Shield

    Follow the specific cable preparation steps (A, B, or C) that apply to your cable type. If using a 20MA or 21MA grounding device or 600ECS Jacket Cable Seal, refer to their instructions. For UNISHIELD* or LEAD SHEATH cable, use a 10TL cable shield adapter and refer to its instructions. For jacketed and non-jacketed cables, remove the outer jacket (if applicable) and prepare the cable according to the provided diagrams, ensuring correct dimensions for cable insulation, semi-con shield, and tape markers.

  5. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  6. Prepare the Conductor Length

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Be careful not to cut or nick the cable adapter or the conductor. The exposed conductor length must be between 4-3/8 inches to 4-3/4 inches (111mm-121mm). If the length is outside this range, redo the assembly.

  7. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the 'Check Dimension' before crimping; it must be less than 7 inches (178mm). Crimp the compression lug following the instructions supplied with the lug. After crimping, wipe off any excess inhibitor from the compression lug and cable adapter surface. The distance from the end of the compression lug to the cable adapter must be between 6-7/8 inches to 7-5/8 inches (175mm-194mm). If dimensions are incorrect, redo the assembly.

  8. Install the Elbow onto the Cable Adapter

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Verify that the cable adapter remains flush with the tape marker. If not, reposition the cable adapter. Once correctly positioned, remove the tape marker.

  9. Prepare Mating Product and Install Threaded Stud

    DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove any protective caps from the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  10. Connect Elbow to Mating Part

    Push the elbow onto the mating part, carefully aligning the hole in the compression lug with the stud on the mating part.

  11. Connect Opposite Mating Part

    Clean and lubricate the mating part intended for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part.

  12. Install Insulating Plug (If Applicable)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down firmly until it snaps into place. CAUTION: The insulating plug provides a means for detecting system voltage; follow the VOLTAGE TEST directions in Step 14.

  13. Ground the Cable Shield

    Insert one end of a wire (with ampacity at least equivalent to No. 14 AWG Copper) through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow instructions supplied with any grounding device or use an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  14. Perform Voltage Test (If Applicable)

    CAUTION: When constructing 600amp L-Kits, ensure each component is tightened to the specified torque per plug connector instructions. If the connector has an integral capacitance test point, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Contamination or incorrect equipment can give a false 'no voltage' indication. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.