ABB - Installation Products 756LR-L0310-S - 35kV, 600 Amps, Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 400 kcmil or Compacted/Solid 450 kcmil or Compact 240 mm2. Cold-Shrinkable Jacket Seal Included.

ABB Installation Products 756LR-L0310-S 35kV, 600 Amps, Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and…

UPC: 075114388061


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 756LR-L0310-S is a 35kV, 600 Amp deadbreak elbow connector designed for reliable electrical connections in medium voltage applications. This unit features a built-in test point for safe and efficient testing, ensuring operational integrity. It includes an insulated plug, cap, stud, lug, and cable adapter for comprehensive connectivity. The connector utilizes an aluminum compression lug, suitable for conductor sizes ranging from 400 kcmil compressed/stranded or 450 kcmil compacted/solid, up to 240 mm2 compact conductors. The cable insulation diameter compatibility is between 1.180 inches and 1.465 inches, accommodating a range of cable specifications. A cold-shrinkable jacket seal is included, providing a robust environmental seal and ensuring long-term performance and protection against moisture and contaminants. This deadbreak elbow is engineered for secure and dependable termination of medium voltage cables, facilitating safe power distribution and system maintenance. Its construction prioritizes electrical safety and mechanical durability, making it a critical component for utility and industrial power systems. The UNSPSC code for this product is 39121421. Manufacturer: ABB - Installation Products.
  • 35kV, 600 Amps rated deadbreak elbow connector
  • Integrated test point for safe testing procedures
  • Includes insulated plug, cap, stud, lug, and cable adapter
  • Aluminum compression lug for 400-450 kcmil or 240 mm2 conductors
  • Cold-shrinkable jacket seal for environmental protection

Specifications

Amperage Rating
600 A
Application
35 kv, 600 Amp
Color
Black
Conductor Range
400 kcmil , 450 kcmil
Connection
Compression
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Special Features
35kV, 600 Amp Deadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. S - Cold-Shrinkable Jacket Seal
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Width
12.28 in
Width
311.912 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240.

755LR-J0310

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit with Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size Compressed/Stranded 700/750 kcmil or Compact/Solid 900. Includes Elbow Housing, Reducing Tap Plug, Cable Size Adapter, Compression Lug, Lubricant, Instruction Sheet and Crimp Chart.

656LRTP-M0380-DRG

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit with Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size Compressed/Stranded 700/750 kcmil or Compact/Solid 900. Includes Elbow Housing, Reducing Tap Plug, Cable Size Adapter, Compression Lug, Lubricant, Instruction Sheet and Crimp Chart.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch (24.892-29.972mm). Aluminum Compression Lug, Conductor Size 800 Stranded/Compressed or 500 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-J0390

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch (24.892-29.972mm). Aluminum Compression Lug, Conductor Size 800 Stranded/Compressed or 500 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch (27.686-33.274mm). Aluminum Compression Lug, Conductor Size 400 Stranded/Compressed or 450 Solid/Compact or 240 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-K0310

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch (27.686-33.274mm). Aluminum Compression Lug, Conductor Size 400 Stranded/Compressed or 450 Solid/Compact or 240 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.980-1.180 inches (24.894-29.972mm). Aluminum Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Solid/Compact or 125mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-J0270

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.980-1.180 inches (24.894-29.972mm). Aluminum Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Solid/Compact or 125mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.760-0.950 inches (19.304-24.130mm). Aluminum Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-G0240

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.760-0.950 inches (19.304-24.130mm). Aluminum Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
35kV, 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Shearbolt Lug and Cable Adapter). Tin-Plated Aluminum Shearbolt Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size Range for Compressed / Stranded / Compacted / Solid 750 to 1250 kcmil. Cold-Shrinkable Jacket Seal Included.

756LR-PAC04-S

35kV, 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Shearbolt Lug and Cable Adapter). Tin-Plated Aluminum Shearbolt Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size Range for Compressed / Stranded / Compacted / Solid 750 to 1250 kcmil. Cold-Shrinkable Jacket Seal Included.
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Compacted Solid 350 or mmSquared Compact 150.

K675LR-M2290

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Compacted Solid 350 or mmSquared Compact 150.

Frequently Asked Questions

What is the maximum operating voltage for this deadbreak elbow?

The deadbreak elbow connector is rated for 35kV, making it suitable for medium voltage applications.

What conductor sizes can this ABB elbow accommodate?

It supports 400 kcmil compressed/stranded, 450 kcmil compacted/solid, or 240 mm2 compact conductors.

What is the compatible cable insulation diameter range?

The cable insulation diameter range for this connector is 1.180 inches to 1.465 inches.

Does this deadbreak elbow include a test point?

Yes, this model features a built-in test point for convenient and safe testing.

What type of lug is used with this connector?

This deadbreak elbow utilizes an aluminum compression lug.

How to Install 756/776LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 756LR or 776LR Deadbreak Elbow Connectors on 35kV class systems. It covers cable preparation, connector assembly, and grounding procedures.

Estimated time: 2h

Tools needed:

Wire strippers, Crimping tool, Wire brush, Hotstick, Suitable sensing device (for capacitive test points)

Supplies needed:

756LR or 776LR Deadbreak Elbow Connector kit, Lubricant (supplied with kit), Threaded stud (supplied with elbow, if needed), Grounding wire (min. No. 14 AWG Copper), Suitable connector (for grounding wire), Waterproofing material (for cable jacket), HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Ensure Safety and Inspect Components

    DANGER: De-energize all apparatus before beginning installation or removal of parts. Do not touch or move energized products. Inspect all parts for damage, proper rating, and compatibility with mating parts. Ensure all required tools are at hand and maintain cleanliness throughout the procedure.

  2. Position and Cut Cable

    Position the cable in its final assembled location, ensuring enough slack for elbow removal. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.

  3. Clean Cable Outer Jacket

    Clean the outer jacket of the cable for a distance of 24 inches (610mm).

  4. Prepare Cable for Connector

    Follow the specific cable preparation instructions (STEPS A, B, or C) that apply to your cable type (e.g., UNISHIELD, LEAD SHEATH, Jacketed, or Non-Jacketed Concentric Neutral Wires). This involves removing the outer jacket (if applicable) and preparing the cable insulation and semi-con shield to the specified dimensions using a tape marker.

  5. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  6. Prepare Conductor Length

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Ensure not to cut or nick the cable adapter or the conductor. The exposed conductor length must be between 4-3/8 inches to 4-3/4 inches (111mm-121mm). If not, redo the assembly.

  7. Insert and Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the lug. Measure the 'Check Dimension' before crimping (should be less than 7 inches / 178mm). Crimp the compression lug according to the supplied instructions. Wipe off any excess inhibitor. After crimping, the distance from the end of the lug to the cable adapter should be 6-7/8 inches to 7-5/8 inches (175mm-194mm). If not, redo the assembly.

  8. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Verify the cable adapter is still flush with the tape marker; reposition if necessary. Remove the tape marker.

  9. Prepare and Connect to Mating Product

    DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. Remove protective caps from the elbow and the mating part. If the mating part lacks a stud, hand tighten the threaded stud (supplied with the elbow) into it. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Push the elbow onto the mating part, aligning the compression lug hole with the stud.

  10. Connect Opposite End Mating Part (if applicable)

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to its specific instructions.

  11. Install Insulating Plug (if used)

    If using an insulating plug, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down firmly until it snaps into place. CAUTION: The insulating plug provides a means for detecting system voltage; follow voltage test directions carefully.

  12. Ground the Cable Shield

    Insert one end of a grounding wire (at least No. 14 AWG Copper) through the grounding eye and twist to form a small loop, ensuring not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded either via a grounding device (following its instructions) or an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  13. Perform Voltage Test (Optional but Recommended)

    If the connector has an integral capacitance test point, remove the test point cap with a hotstick (peel off at an angle). WARNING: This is a capacitance device, not directly connected to the conductor. Use a suitable sensing device designed for capacitive test points and follow its manufacturer's directions. Contamination or incorrect equipment can give a false 'no voltage' indication. Treat the elbow as energized until the 'no voltage' test is confirmed by other means. After testing, clean and lubricate the cap's inside surface and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.