Authorized ABB Distributor (Installation Products)
ABB - Installation Products K465LR-K0310 - 15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch (27.686-33.274mm). Aluminum Compression Lug, Conductor Size 400 Stranded/Compressed or 450 Solid/Compact or 240 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

ABB Installation Products K465LR-K0310 15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.090…

UPC: 075114377867


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K465LR-K0310 deadbreak elbow connector delivers reliable medium-voltage cable terminations for underground power distribution systems. Rated for 15/25 kV and 630 amperes, this deadbreak elbow is engineered to accommodate cable insulation diameters between 1.090 inches and 1.310 inches (27.686-33.274mm), ensuring broad compatibility with medium-voltage cables in utility, industrial, and commercial applications. This connector features an aluminum compression lug designed for stranded/compressed conductors up to 400 kcmil, solid/compact conductors up to 450 kcmil, or 240 mm² conductors. The deadbreak design enables safe connection and disconnection of energized circuits without interrupting service, providing a fully shielded and submersible interface. The K465LR series excludes a test point, optimizing the design for applications where testing is performed via alternative methods. The kit includes all necessary components for installation: elbow connector housing, aluminum compression lug, stud, insulated plug with cap, tube lubricant, cable adapter, installation instructions, and crimp chart. Its robust construction and deadbreak functionality make it ideal for underground electrical systems requiring reliable, low-resistance terminations in harsh environments.
  • Rated for 15/25 kV and 630 amperes for medium-voltage applications
  • Accommodates cable insulation diameters from 1.090" to 1.310" (27.686-33.274mm)
  • Aluminum compression lug supports 400 kcmil stranded/compressed or 450 kcmil solid/compact conductors
  • Deadbreak design allows safe connection/disconnection of energized circuits
  • Includes elbow housing, compression lug, stud, insulated plug with cap, tube lubricant, cable adapter, and installation kit

Specifications

Amperage Rating
630 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
400 kcmil , 450 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators
Standard
ANSI/IEEE Standard 386/ IEC
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV, 600 Amps, Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 400 kcmil or Compacted/Solid 450 kcmil or Compact 240 mm2. Cold-Shrinkable Jacket Seal Included.

756LR-L0310-S

35kV, 600 Amps, Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 400 kcmil or Compacted/Solid 450 kcmil or Compact 240 mm2. Cold-Shrinkable Jacket Seal Included.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.980-1.180 inches (24.894-29.972mm). Aluminum Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Solid/Compact or 125mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-J0270

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.980-1.180 inches (24.894-29.972mm). Aluminum Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Solid/Compact or 125mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.760-0.950 inches (19.304-24.130mm). Aluminum Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-G0240

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.760-0.950 inches (19.304-24.130mm). Aluminum Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
35kV, 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Shearbolt Lug and Cable Adapter). Tin-Plated Aluminum Shearbolt Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size Range for Compressed / Stranded / Compacted / Solid 750 to 1250 kcmil. Cold-Shrinkable Jacket Seal Included.

756LR-PAC04-S

35kV, 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Shearbolt Lug and Cable Adapter). Tin-Plated Aluminum Shearbolt Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size Range for Compressed / Stranded / Compacted / Solid 750 to 1250 kcmil. Cold-Shrinkable Jacket Seal Included.
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Compacted Solid 350 or mmSquared Compact 150.

K675LR-M2290

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Compacted Solid 350 or mmSquared Compact 150.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.850-1.050 inches (21.590-26.670mm). Aluminum Compression Lug, Conductor Size 3/0 Stranded/Compressed or 4/0 Solid/Compact or 95mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-H0260

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.850-1.050 inches (21.590-26.670mm). Aluminum Compression Lug, Conductor Size 3/0 Stranded/Compressed or 4/0 Solid/Compact or 95mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
35kV, 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Shearbolt Lug and Cable Adapter). Tin-Plated Aluminum Shearbolt Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Range for Compressed / Stranded / Compacted / Solid #2 to 300 kcmil. Cold-Shrinkable Jacket Seal Included.

756LR-JAC01-S

35kV, 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Shearbolt Lug and Cable Adapter). Tin-Plated Aluminum Shearbolt Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Range for Compressed / Stranded / Compacted / Solid #2 to 300 kcmil. Cold-Shrinkable Jacket Seal Included.
35kV, 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Shearbolt Lug and Cable Adapter). Tin-Plated Aluminum Shearbolt Lug. Cable Insulation Diameter 1.18 inch to 1.465 inch. Conductor Size Range for Compressed / Stranded / Compacted / Solid #2 to 300 kcmil. Cold-Shrinkable Jacket Seal Included.

756LR-LAC01-S

35kV, 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Shearbolt Lug and Cable Adapter). Tin-Plated Aluminum Shearbolt Lug. Cable Insulation Diameter 1.18 inch to 1.465 inch. Conductor Size Range for Compressed / Stranded / Compacted / Solid #2 to 300 kcmil. Cold-Shrinkable Jacket Seal Included.

Frequently Asked Questions

What is the AC one-minute withstand voltage for K465LR?

The K465LR has an AC one-minute withstand voltage of 55kV.

What is the impulse withstand rating for the K465LR?

The K465LR has a 140kV BIL Impulse Withstand rating, measured with a 1.2 x 50 microsecond wave.

What are the short circuit ratings for the K465LR?

The short circuit ratings are > 28 kA RMS symmetrical and > 70 kA peak asymmetrical.

What is the continuous current rating for the K465LR?

The K465LR has a continuous current rating of 630 Amps. It can handle 1250 Amps if the connected equipment is also rated for 1250A.

What cable insulation diameters does the K465LR accommodate?

The K465LR accommodates insulation diameters from 0.640 inches to 1.935 inches.

What conductor types and sizes are compatible with K465LR?

It is compatible with aluminum and copper conductors ranging from 1/0 to 1250 kcmil.

What voltage classes does the K465LR support?

The K465LR is fully rated for 15/25kV and can be used through 28kV. Its maximum phase-to-phase operating voltage is 28kV.

What is the K465LR elbow connector's primary application?

The K465LR provides fully shielded, dead-front submersible cable connections to high-voltage apparatus. It is designed for use through 28kV.

What is the impulse withstand rating for the K465LR?

The K465LR has a 140kV BIL Impulse Withstand rating, measured with a 1.2 x 50 microsecond wave.

What is the K465LR elbow connector's primary application?

The K465LR provides fully shielded, dead-front submersible cable connections to high-voltage apparatus. It is designed for use through 28kV.

How to Use the M16 to 5/8-11 Thread Conversion Stud

This guide explains how to properly utilize the double-ended stud to convert an M16 metric thread to a 5/8-11 English thread for various applications, ensuring correct identification and secure fastening.

Estimated time: 5m

Tools needed:

Wrench

Supplies needed:

Double-ended stud (M16 to 5/8-11)

  1. Identify the M16 Threaded End

    Locate the M16 threaded end of the double-ended stud. This end is clearly marked with an 'M' for easy identification, indicating the metric thread.

  2. Connect the M16 Side

    Thread the identified M16 end of the stud into the component or fixture that has a corresponding M16 female thread. Hand-tighten first, then use a wrench to ensure it is securely fastened without overtightening.

  3. Connect the 5/8-11 English Thread Side

    Attach the component requiring a 5/8-11 English thread to the remaining exposed end of the stud. Thread it on carefully and tighten until secure, using a wrench if necessary, to complete the conversion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.