Authorized ABB Distributor (Installation Products)
ABB - Installation Products 755ETP-J0230-DRG - 600 Amp, Test and Ground Connector Kit, 35KV, DeadBreak, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

ABB Installation Products 755ETP-J0230-DRG 600 Amp, Test and Ground Connector Kit, 35KV, DeadBreak, Cable Insulation Diameter 0.980…

UPC: 783786476701


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 755ETP-J0230-DRG is a 600 Amp, 35KV DeadBreak Test and Ground Connector Kit designed for reliable electrical connections in medium-voltage applications. This kit features an aluminum compression lug, ensuring robust and secure termination for conductors ranging from AWG #1 compressed stranded to solid 1/0, with a millimeter-squared equivalent of 42.41. Engineered for cable insulation diameters between 0.980 inches and 1.180 inches, this connector provides a precise fit for specified cable sizes, crucial for maintaining system integrity and preventing electrical faults. The DeadBreak connection type signifies its suitability for applications requiring a fully shielded, separable connector that can be energized and de-energized under load conditions, offering enhanced safety and operational flexibility. This kit is essential for testing, grounding, and connecting medium-voltage power systems, including substations, industrial facilities, and utility distribution networks. The aluminum construction of the compression lug offers excellent conductivity and corrosion resistance, contributing to the longevity and performance of the connection. ABB's Installation Products division is known for delivering dependable solutions, and the 755ETP-J0230-DRG is no exception, meeting the stringent requirements of power system maintenance and installation professionals. Key specifications include a 600 Amp current rating and a 35KV voltage rating, making it suitable for a broad range of medium-voltage power distribution tasks. The specific cable insulation diameter range ensures compatibility with commonly used medium-voltage cable constructions.
  • 600 Amp current rating
  • 35KV voltage rating
  • DeadBreak connection type
  • Aluminum compression lug
  • Cable insulation diameter: 0.980" - 1.180"

Specifications

Amperage Rating
600 A
Application
600 Amps, 35kV
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Connection
Compression
Insulation
EPDM Rubber
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 0.980-1.180 inches
Special Features
Includes Insulated Cap
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Window-Op Connector
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

756LR-K2230-SG3

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
600 Amp, 25KV, DeadBreak, Elbow Connctor, Test and Ground Connector Kit, with Insulated Cap, Reducing Tap Plug, Elbow Housing, Cable Adapter, and Lug, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K655ETPL0320DRGSG3

600 Amp, 25KV, DeadBreak, Elbow Connctor, Test and Ground Connector Kit, with Insulated Cap, Reducing Tap Plug, Elbow Housing, Cable Adapter, and Lug, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
600 Amp, Test and Ground Connector Kit, 35KV, DeadBreak, 600 Amp, Test and Ground Connector Kit, 35KV, DeadBreak, Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

755ETP-P0380-DRG

600 Amp, Test and Ground Connector Kit, 35KV, DeadBreak, 600 Amp, Test and Ground Connector Kit, 35KV, DeadBreak, Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
600 Amp, 25KV, DeadBreak, Elbow Connector, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

K655ETP-J5270

600 Amp, 25KV, DeadBreak, Elbow Connector, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
600 Amp, 25KV, DeadBreak, Elbow Connector, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

K655ETP-J0270

600 Amp, 25KV, DeadBreak, Elbow Connector, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
600 Amp Dead Break Elbow Connector, Test and Ground Connector Kit, 15 KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 350 /Solid 400 /mmSquared 185.

655ETP-J0300-DRG

600 Amp Dead Break Elbow Connector, Test and Ground Connector Kit, 15 KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 350 /Solid 400 /mmSquared 185.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

655ETP-P0410-DRG

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. 200ECS Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.

656ETP-K0320-DRG-S

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. 200ECS Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.

Frequently Asked Questions

What is the primary use of WINDOW-OP connectors?

WINDOW-OP connectors allow direct testing and grounding without cable movement. They are ideal for equipment with viewing windows for an internal visible break.

What types of connector materials are available?

Available connector material types include Universal Aluminum, Copper, and Bi-metal.

How is the catalog number determined for ordering?

The catalog number is determined by selecting a W code for insulation diameter, choosing the connector material type, and an X code for the compression lug based on conductor size.

What components are included in the connector kit?

The kit includes an Elbow Housing, Tap Plug, Insulated Cap, Cable Size Adapter, Compression Lug, Stud, Silicone Lubricant, instruction sheets, and a crimp chart.

What standards does the connector meet?

The connector meets ANSI/IEEE Standard 386, Latest Revision.

What is the impulse withstand rating for this connector?

The impulse withstand (BIL) rating for the connector is 150kV (1.2 x 50 microsecond wave).

What is the continuous current rating of the connector?

The WINDOW-OP connector has a continuous current rating of 600 Amps.

What is the maximum operating voltage for this connector?

For the 35kV voltage class, the maximum phase-to-ground operating voltage is 21.1kV.

What types of connector materials are available?

Available connector material types include Universal Aluminum, Copper, and Bi-metal.

What is the primary use of WINDOW-OP connectors?

WINDOW-OP connectors allow direct testing and grounding without cable movement. They are ideal for equipment with viewing windows for an internal visible break.

How to Install the 750/775 ETP Elbow Tap Plug

This guide provides step-by-step instructions for the safe installation and assembly of the 750/775 ETP Elbow Tap Plug, designed for 35kV systems to provide a 200 ampere loadbreak tap. Ensure all safety precautions are followed.

Estimated time: 1h

Tools needed:

Torque wrench, Wire strippers, Crimping tool, Appropriate tool for drive adapter

Supplies needed:

750/775 ETP Tap Plug, Lubricant (supplied or ELASTIMOLD approved), Double-ended stud (if applicable), #14AWG copper wire (or equivalent), Grounding connector, Waterproofing material, DR(G), ESA, GLR, or LR connector (appropriate voltage class)

  1. De-energize Apparatus and Prepare Cable

    DANGER: Ensure all apparatus is de-energized before beginning installation or removal of parts. Prepare the cable using a spade contact and install the elbow connector according to the specific (K)650LR or 750LR installation instructions. Align the spade contact flat on the apparatus bushing contact before making the first crimp.

  2. Prepare Tap Plug and Lubricate Interfaces

    Remove the protective caps from both the elbow connector and the tap plug. If applicable, finger tighten the double-ended stud into the tap plug. Thoroughly clean and lubricate the entire mating connector interface, elbow connector interfaces, and the tap plug using the supplied lubricant or an ELASTIMOLD approved lubricant.

  3. Assemble Elbow and Tap Plug

    Assemble the elbow connector onto the mating connector. Then, assemble the tap plug into the elbow connector. Insert the drive adapter into the tap plug and turn it in a clockwise direction while simultaneously pushing the elbow and tap plug toward the mating connector. Continue rotating the drive adapter clockwise with an appropriate torque wrench to a torque of 50-60 ft-lbs. Finally, remove the drive adapter from the tap plug.

  4. Install Grounding Wire to Elbow

    Insert one end of a length of #14AWG copper wire (or equivalent) through the grounding eye of the elbow. Leave sufficient length to allow for potential movement of the elbow if required. Form a small loop and twist it tightly, taking care not to damage the grounding eye.

  5. Ground Cable Shield and Elbow

    For concentric wire shielded cable, twist the shield wires together and connect them, along with the grounding eye wire, to a common ground point using an appropriate connector. For metallic tape shielded cable, connect the metallic shield of the cable to ground using a jumper of equivalent ampacity, and also connect the elbow connector grounding eye wire to ground. Ensure sufficient length is left to allow movement of the elbow. For three-phase installations, all grounds from all three phases must be tied to a common ground point. If the cable is jacketed, install appropriate waterproofing at the jacket terminus to prevent moisture from entering.

  6. Install Final Connector or Insulated Cap

    Clean and lubricate the entire tap plug interface. Install either a DR(G), ESA, GLR, or LR connector of the appropriate voltage class onto the tap plug interface, following the specific installation instructions provided with that product. Ensure the interface is well-lubricated with the supplied or ELASTIMOLD approved lubricant.

  7. Verify Proper Seating

    Visually inspect the assembled insulated cap or elbow. Complete and proper assembly is indicated when no portion of the black band is visible when viewed from the side.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.