ABB - Installation Products K655ETP-J0270 - 600 Amp, 25KV, DeadBreak, Elbow Connector, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

ABB Installation Products K655ETP-J0270 600 Amp, 25KV, DeadBreak, Elbow Connector, Cable Insulation Diameter 0.980 inch to 1.180…

UPC: 783786534623


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products K655ETP-J0270 is a 600 Amp, 25kV deadbreak elbow connector engineered for medium-voltage cable systems in industrial and utility applications. This connector accommodates cable insulation diameters from 0.980 inch to 1.180 inch, ensuring compatibility with a range of cable types including compressed stranded and solid conductors sized from 4/0 AWG to 250 mm². The K655ETP-J0270 features an aluminum compression lug for reliable, low-resistance connections critical in switchgear, transformers, and pad-mounted equipment where insulated connections must be made without de-energizing the system. Its elbow design enables quick installation and removal while maintaining system integrity, reducing downtime during maintenance or upgrades. Designed for harsh environments, this deadbreak connector meets stringent electrical and mechanical standards for medium-voltage applications. The fully shielded, molded rubber housing provides submersible protection, ensuring long-term performance in utility, commercial, and industrial power distribution systems where reliability and safety are paramount.
  • 600 Amp, 25kV deadbreak elbow connector for medium-voltage systems
  • Accommodates cable insulation diameters from 0.980" to 1.180"
  • Compatible with 4/0 AWG to 250 mm² conductors (compressed stranded or solid)
  • Aluminum compression lug ensures low-resistance, reliable connections
  • Elbow design allows quick installation/removal without system de-energization

Specifications

Amperage Rating
600 A
Application
600 Amps, 25kV
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 SOL/COMPT kcmil
Connection
Compression
Insulation
EPDM Rubber
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 0.980 inch to 1.180 inch
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Window-Op Connector
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25kV, 600 Amps, Combo T connecting Plug with Bus Stud, Cable Adapter and Lug Kit, No Sealing Kit, Cable Insulation Diameter 0.98-1.18 inches (24.9-30.0mm), Aluminum Lug, 4/0 Stranded/Compressed AWG or 250 Solid/Compact kcmil. With Test Point.

K656CCP-J0270

25kV, 600 Amps, Combo T connecting Plug with Bus Stud, Cable Adapter and Lug Kit, No Sealing Kit, Cable Insulation Diameter 0.98-1.18 inches (24.9-30.0mm), Aluminum Lug, 4/0 Stranded/Compressed AWG or 250 Solid/Compact kcmil. With Test Point.
600 Amp Dead Break Elbow Connector, Test and Ground Connector Kit, 15 KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 350 /Solid 400 /mmSquared 185.

655ETP-J0300-DRG

600 Amp Dead Break Elbow Connector, Test and Ground Connector Kit, 15 KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 350 /Solid 400 /mmSquared 185.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

655ETP-P0410-DRG

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. 200ECS Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.

656ETP-K0320-DRG-S

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. 200ECS Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

656ETP-K0360

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. 200ECS Cold-Shrinkable Jacket Seal Included.

656ETP-G0240-DRG-S

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. 200ECS Cold-Shrinkable Jacket Seal Included.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. 200ECS Cold-Shrinkable Jacket Seal Included.

655ETP-M0380-DRG-S

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. 200ECS Cold-Shrinkable Jacket Seal Included.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. 200ECS Cold-Shrinkable Jacket Seal Included.

655ETP-N0380-S

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. 200ECS Cold-Shrinkable Jacket Seal Included.

Frequently Asked Questions

What is the purpose of WINDOW-OP connectors?

WINDOW-OP connectors allow direct testing and grounding without requiring cable movement. They are ideal for equipment with viewing windows for an internal visible break.

What conductor size corresponds to the '270' X Code?

The '270' X Code corresponds to 4/0 AWG or 250 kcmil conductor sizes for Universal Aluminum, Copper, or Bi-metal connectors.

What is the corona extinction voltage?

The corona extinction voltage is 21.5kV AC at 3pC sensitivity.

What is the DC 15-minute withstand voltage rating?

The DC 15-minute withstand voltage rating is 84kV.

What is the AC one-minute withstand voltage rating?

The AC one-minute withstand voltage rating is 45kV.

What is the impulse withstand rating (BIL)?

The impulse withstand (BIL) rating is 140kV, based on a 1.2 x 50 microsecond wave.

Which ANSI/IEEE standard does this connector meet?

The connector meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating?

The connector has a continuous current rating of 600 Amps.

What is the maximum operating voltage for this connector?

For the 28kV Voltage Class, the maximum phase-to-ground operating voltage is 16.2kV. The maximum phase-to-phase voltage is 28kV.

What is the maximum operating voltage for this connector?

For the 28kV Voltage Class, the maximum phase-to-ground operating voltage is 16.2kV. The maximum phase-to-phase voltage is 28kV.

How to Install and Remove the 160DRG/167DRG Insulated Cap with Ground Lead

This guide provides instructions for the safe installation and removal of the ELASTIMOLD 15kV class 160DRG and 167DRG insulated caps with ground lead, designed for insulating, shielding, and watersealing loadbreak bushing interfaces.

Estimated time: 20m

Tools needed:

Hotstick

Supplies needed:

Insulated Cap with Ground Lead, Lubricant

  1. Connect Grounding Wire

    Connect the free end of the electrostatic grounding wire to the system ground, ensuring enough slack for hot-stick operation of the insulated cap. CAUTION: Train the electrostatic grounding wire so as not to contact the bushing interface during operation. WARNING: If the ground lead disconnects during operation, do not attempt to reattach without first pulling the insulated cap off the bushing with the hotstick.

  2. Prepare Insulated Cap

    Remove the protective cover from the insulated cap and lubricate the cap's internal mating surface. Use only the supplied lubricant or ELASTIMOLD approved lubricants; do not substitute, as other lubricants may be harmful. Keep the internal mating surface free from dirt and grime. Always replace the protective cover when not in use.

  3. Attach Insulated Cap to Bushing

    Firmly attach a hotstick to the insulated cap's pulling eye. Insert the male contact of the insulated cap into the loadbreak bushing, and push it home with a fast, firm, straight motion. Make certain it is fully mated, with the locking ring seated. Detach the hotstick from the insulated cap.

  4. Remove Insulated Cap

    Attach a hotstick to the pulling eye of the insulated cap. Before pulling, rotate the insulated cap clockwise slightly while in the mated position to break surface friction. Pull the receptacle off with a fast, firm, straight motion to complete the operation. Remove the electrostatic grounding wire of the insulated cap from the system ground. Replace the protective cover on the insulated cap to keep its internal surface clean.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.