Authorized ABB Distributor (Installation Products)
ABB - Installation Products 655ETP-P0410-DRG - 15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

ABB Installation Products 655ETP-P0410-DRG 15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test…

UPC: 075114167338


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 655ETP-P0410-DRG is a complete 15kV 600 Series Deadbreak Elbow TAP PLUG Connector Kit designed for safe, reliable medium-voltage electrical connections in utility, industrial, and commercial power distribution systems. This kit includes all critical components for terminating and testing 1000 kcmil compressed stranded conductors with cable insulation diameters between 1.725 and 1.935 inches. The core of the kit is the 600 series Elbow housing, engineered to ANSI/IEEE Standard 386 for deadbreak operation at 15kV class (8.3kV phase-to-ground, 14.4kV phase-to-phase). The kit features a reducing tap plug for test and ground functionality, an insulated protective cap, a cable adapter for compatibility, and a 0370 style aluminum compression lug rated for 1000 kcmil conductors. The deadbreak interface supports 600A continuous current with a 25kA symmetrical momentary rating, while the loadbreak interface enables 200A continuous and loadbreak operations with a 10kA symmetrical momentary rating. The peroxide-cured insulation and jacket ensure long-term reliability and corona extinction at 11kV AC. This kit is essential for applications requiring safe, non-interruptive testing and grounding in medium-voltage systems, including pad-mounted transformers, switchgear, and cable terminations. The included components simplify installation and maintenance, reducing downtime and improving operational safety. Compatible with mating connectors including 167DR, 167DRG, 167ESA-XX, 165LR, and others in the 600 series ecosystem.
  • 15kV class deadbreak operation (8.3kV phase-to-ground, 14.4kV phase-to-phase)
  • Supports 600A continuous current with 25kA symmetrical momentary rating
  • Loadbreak interface rated for 200A continuous and 10kA symmetrical momentary
  • Includes test/ground reducing tap plug, insulated cap, cable adapter, and 0370 aluminum compression lug
  • Compatible with 600 series mating connectors (167DR, 167DRG, 167ESA-XX, 165LR)

Specifications

Amperage Rating
600 A
Application
600 Amps, 15kV
Color
Black
Conductor Range
1000 STR/COMPR kcmil
Connection
Compression
Insulation
EPDM Rubber
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 1.725 inch to 1.935 inch
Special Features
Includes Insulated Cap
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Window-Op Connector
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

655ETP-N0410-DRG

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. 200ECS Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.

656ETP-K0320-DRG-S

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. 200ECS Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

656ETP-K0360

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Window-Op Connector Kit. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. 200ECS Cold-Shrinkable Jacket Seal Included.

656ETP-G0240-DRG-S

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. 200ECS Cold-Shrinkable Jacket Seal Included.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. 200ECS Cold-Shrinkable Jacket Seal Included.

655ETP-M0380-DRG-S

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. 200ECS Cold-Shrinkable Jacket Seal Included.
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. 200ECS Cold-Shrinkable Jacket Seal Included.

655ETP-N0380-S

15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. 200ECS Cold-Shrinkable Jacket Seal Included.
25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded #1 or 2/0 Compacted/Solid. With Insulated Cap.

K655ETP-H0240-DRG

25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded #1 or 2/0 Compacted/Solid. With Insulated Cap.
600 Amp, 35kV, Deadbreak, Test and Ground Connector kit, includes Insulated cap, reducing tap plug, elbow housing, cable adapter and 0370 style compression lug. 600ATM assembly tool required, 50-60 foot/pounds torrque wrench required but not included. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. With Sealing kit

755ETP-J0240-DRG-S

600 Amp, 35kV, Deadbreak, Test and Ground Connector kit, includes Insulated cap, reducing tap plug, elbow housing, cable adapter and 0370 style compression lug. 600ATM assembly tool required, 50-60 foot/pounds torrque wrench required but not included. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. With Sealing kit

Frequently Asked Questions

What is the voltage rating of this deadbreak elbow kit?

The ABB 655ETP-P0410-DRG deadbreak elbow kit has a voltage rating of 15kV.

What is the compatible cable insulation diameter range?

This kit is designed for cable insulation diameters ranging from 1.725 inches to 1.935 inches.

What type of conductor does the compression lug support?

The kit includes an aluminum compression lug suitable for compressed stranded conductors up to 1000 kcmil.

What components are included in the test and ground kit?

The test and ground kit includes an insulated cap and a reducing tap plug for testing and grounding.

What is the series of the deadbreak elbow housing?

The deadbreak elbow housing included in this kit is from the 600 Series.

How to Install the ELASTIMOLD 160DRG/167DRG Insulated Cap with Ground Lead

This guide provides instructions for installing the ELASTIMOLD 160DRG and 167DRG insulated caps, designed for insulating, shielding, and watersealing 15kV class loadbreak bushing interfaces. Ensure all apparatus is de-energized before installation.

Estimated time: 15m

Tools needed:

Hotstick

Supplies needed:

Insulated Cap with Ground Lead, ELASTIMOLD Approved Lubricant

  1. Connect Grounding Wire

    Connect the free end of the electrostatic grounding wire to the system ground, leaving enough slack for hot-stick operation of the insulated cap. CAUTION: Train the electrostatic grounding wire so as not to contact the bushing interface during operation.

  2. Prepare Insulated Cap

    Remove the protective cover from the insulated cap and lubricate the cap's internal mating surface. Use only the supplied lubricant or ELASTIMOLD approved lubricants; do not substitute, as other lubricants may be harmful. Keep the internal mating surface free from dirt and grime. Always replace the protective cover when the cap is not in use.

  3. Install Insulated Cap

    Firmly attach a hotstick to the insulated cap pulling eye. Insert the male contact of the insulated cap into the loadbreak bushing, and push it home with a fast, firm, straight motion. Make certain it is fully mated, with the locking ring seated. Detach the hotstick from the insulated cap.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.