Authorized ABB Distributor (Installation Products)
ABB - Installation Products 750J4-U - 35kV 600 Series Deadbreak 4-Point Junction, with adjustable bracket. Consists of Rubber Junction with Stainless Steel Mounting Plate, Back Plate and Adustable Mounting Bracket.

ABB Installation Products 750J4-U 35kV 600 Series Deadbreak 4-Point Junction, with adjustable bracket. Consists of Rubber…

UPC: 783786395453


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 35kV 600A Deadbreak 4-Point Junction (SKU: 750J4-U) is a fully shielded, fully submersible medium-voltage cable accessory designed for reliable 35kV class connections. This deadbreak-rated junction features a 100% peroxide-cured EPDM rubber housing with conductive materials, providing environmental sealing and dielectric protection in harsh conditions. The stainless steel mounting bracket and back plate ensure corrosion resistance and structural integrity, while the adjustable bracket accommodates varying mounting orientations for versatility in installation. Rated for 600A continuous current and 25kA symmetrical momentary withstand, the 750J4-U meets ANSI/IEEE Standard 386 for 35kV voltage class. Key electrical specifications include 21.1kV phase-to-ground operating voltage, 36.6kV maximum phase-to-phase voltage, 150kV BIL impulse withstand, and 50kV AC one-minute withstand. The junction supports hot-stick operation for safe connection and disconnection under load, making it ideal for utility, industrial, and commercial power distribution systems. Designed for subsurface, vault, or padmount applications, the 750J4-U is compatible with Elastimold® Elbow connectors (755 series) and accessories like bushing extenders (755BE) and adapters (755BEA2). Typical applications include sectionalizing, looping, tapping, and equipment bypass in distribution transformers, switchgear, and pad-mounted transformers. Each kit includes the basic molded junction, mounting hardware, lubricant tubes, installation instructions, and protective caps for comprehensive installation support.
  • 35kV voltage class with 600A continuous current rating
  • Fully shielded, submersible EPDM rubber housing with conductive materials
  • Stainless steel mounting bracket and back plate for corrosion resistance
  • Hot-stick operation for safe connection/disconnection under load
  • Compatible with Elastimold® 755 series elbow connectors and accessories

Specifications

Application
35 kV, 600 Amps
Connection Type
Deadbreak
Material
Rubber, Stainless Steel
Mounting Type
Adjustable Bracket
Mounting Type
Adjustable Bracket, Stainless Steel Mounting Plate, Back Plate
Poles
4
Poles
4-Point
Series
600 Series
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Junction 4-Point
Voltage Rating
35 kV
Voltage Rating
35kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
4 Point Junction, with two 200 Amp Bushing Well Interfaces and two 600 Amp Bushing interfaces, 35kV, No Parking Stand.

J4-2266-35-N

4 Point Junction, with two 200 Amp Bushing Well Interfaces and two 600 Amp Bushing interfaces, 35kV, No Parking Stand.
35kV 600 Series Deadbreak 2-Point Junction, includes Rubber Junction, Stainless Steel U-Straps and Back Plate, No Bracket

750-J2-5

35kV 600 Series Deadbreak 2-Point Junction, includes Rubber Junction, Stainless Steel U-Straps and Back Plate, No Bracket
35kV 600 Series Deadbreak 4-Point Junction, includes Rubber Junction, Stainless Steel U-Straps and Back Plate, No Bracket

750J4-5

35kV 600 Series Deadbreak 4-Point Junction, includes Rubber Junction, Stainless Steel U-Straps and Back Plate, No Bracket
200 Amp, 35kV Loadbreak Bushing Insert, Includes internal torquing feature using 200AT Assembly Tool. Includes a black vent ring.

3701A3(1)-H

200 Amp, 35kV Loadbreak Bushing Insert, Includes internal torquing feature using 200AT Assembly Tool. Includes a black vent ring.
15/25kv, Long Shank Well with Bail Tabs and With Replaceable Well Stud (9-1/4 inch Bushing Shank Length), H option

K1601-PC-T1R-H

15/25kv, Long Shank Well with Bail Tabs and With Replaceable Well Stud (9-1/4 inch Bushing Shank Length), H option
900 Amp, 15kV, Loadbreak Elbow Tap Plug, Factory assembled Stud, which is not field removable. Copper.

675ETPSP

900 Amp, 15kV, Loadbreak Elbow Tap Plug, Factory assembled Stud, which is not field removable. Copper.
35 kV, 600 Series Deadbreak Insulated Parking Bushing with Stud and Universal Bracket and EyeBolt, Stand-Off Plug. Length 5.062 inch, Widest Diameter 3 inch. Epoxy.

750SOPS

35 kV, 600 Series Deadbreak Insulated Parking Bushing with Stud and Universal Bracket and EyeBolt, Stand-Off Plug. Length 5.062 inch, Widest Diameter 3 inch. Epoxy.
35kV, 900Amp, Deadbreak/Loadbreak Elbow Tap Plug, use 600ATM assembly tool. Factory assembled Stud, which is not field removable.

775ETPSP

35kV, 900Amp, Deadbreak/Loadbreak Elbow Tap Plug, use 600ATM assembly tool. Factory assembled Stud, which is not field removable.

Frequently Asked Questions

Where can the ELASTIMOLD® junctions be installed?

ELASTIMOLD® junctions are designed for subsurface, vault, or padmount applications.

Is the 750J4 junction submersible?

Yes, the 750J4 junction has a fully shielded, fully submersible molded rubber housing.

What is the operating voltage for the 750J4 junction?

The operating voltage for the 35kV voltage class is 21.1kV Phase-to-Ground.

What is the 750J4 junction's voltage and current rating?

The 750J4 is rated for 35kV voltage class and 600 Amp continuous current.

What is the maximum phase-to-phase voltage?

The maximum phase-to-phase voltage for the 750J4 junction is 36.6kV.

What is the impulse withstand rating of the 750J4?

The 750J4 has a 150kV BIL Impulse Withstand rating (1.2 x 50 microsecond wave).

What is the continuous current rating?

The continuous current rating for the 750J4 junction is 600 Amp.

What is included in the 750J4 kit?

The kit includes the basic molded junction, mounting hardware, lubricant tubes, installation instructions, and protective caps.

What products are compatible with the 750J4 junction?

The 750J4 junction provides mating for Elastimold® Elbow connectors and other Elastimold® products like the 755 Elbow Connector, 755BE Bushing Extender, and 755BEA2 Bushing Adapter.

What is the 750J4 junction's voltage and current rating?

The 750J4 is rated for 35kV voltage class and 600 Amp continuous current.

How to Install the LINK-C Deadbreak Cam Link Operable Connector System

This guide provides step-by-step instructions for the safe and proper installation of the LINK-C 600 amp deadbreak cam link operable connector system. Ensure all apparatus is de-energized and installation is performed by competent personnel trained in high voltage electrical equipment.

Estimated time: 2h

Tools needed:

Hot stick, 600ATM Operating Tool, Wrench for 1 inch hex, Torque wrench, Welding equipment (if applicable), Wire strippers, Crimping tool (for grounding connectors)

Supplies needed:

600 amp elbow, Stand-off plug (if applicable), 3/8-16 x 2” studs (if applicable), 3/8-16 hex nuts, 3/8” lockwashers, Elastimold supplied lubricant, 600 amp bushing extender, Retainer contact, Alignment bracket, Bushing extender clamp, Elbow clamp, Hex bolts and lock washers (for clamps), LINK-C connector, #14 AWG or #12 AWG solid copper wire, Grounding connectors, Desired 200 amp mating product (if applicable)

  1. Prepare the 600 Amp Elbow and Ensure Safety

    WARNING: All apparatus must be de-energized during installation. Install the 600 amp elbow onto the cable following its specific installation instructions. Ensure the elbow is positioned to align correctly with the stand-off plug. Before proceeding, check all package contents for completeness and damage, verify component fit, and gather all required tools and supplies, maintaining cleanliness throughout the procedure.

  2. Install the Mounted Stand-Off Plug (If Applicable)

    If your installation requires a mounted stand-off plug, weld three 3/8-16 x 2” studs to the faceplate according to customer standard practice and specified dimensions. Install three hex nuts onto the studs to support the stand-off plug, ensuring it aligns in-line with the apparatus bushing. Spacers may be used if nuts are not needed for support. Place the stand-off plug over the three studs, resting on the nuts or spacers. Secure the stand-off plug by installing a lockwasher and hex nut on each stud, then tighten each nut to 12 foot-lbs torque. Verify that the top surfaces of the apparatus bushing and stand-off plug are in-line; readjust the nuts as required.

  3. Install the Bushing Extender and Elbow

    Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender with ELASTIMOLD supplied lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM Operating Tool into the retainer contact and engage its internal hex broach. Insert the retainer contact into the bushing extender and thread it into the apparatus bushing using a suitable tool applied to the 1” hex portion of the 600ATM, torquing to 50-60 ft-lbs. Next, clean and thoroughly lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow with ELASTIMOLD supplied lubricant. Install the elbow onto the epoxy standoff plug. Insert the 600ATM Operating Tool into the retainer contact and engage its internal hex broach. Insert the retainer contact into the 600 amp elbow through the hole in the compression lug and thread it into the epoxy standoff plug using a suitable tool applied to the 1” hex portion of the 600ATM, torquing to 50-60 ft-lbs.

  4. Install the Alignment Bracket

    Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender to a dimension of 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket using the supplied hardware. Torque by alternating sides until the clamp tabs are flush with each other and tight on both sides.

  5. Secure the Elbow to the Alignment Bracket

    Position the elbow within the alignment bracket such that the elbow cuff is lined up evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket with the supplied hardware. Torque by alternating sides until the clamp tabs are flush with each other and tight on both sides. IMPORTANT: Ensure the elbow clamp notch faces the cable entrance of the elbow.

  6. Install the LINK-C Connector

    Clean and thoroughly lubricate both 600 ampere interfaces of the LINK-C connector with ELASTIMOLD supplied lubricant. Align the LINK-C connector such that when inserted into the bushing extender and elbow, the Link is perpendicular to the switch faceplate. Insert the LINK-C connector into the bushing extender and elbow, making sure both lever arms are on the inside of the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, use a hot stick to move the lever arms downward, thus engaging the roller pin and moving the LINK-C connector inward. Continue moving the lever arms until they are perpendicular to the alignment bracket leg.

  7. Ground the System

    Ground the elbow: Feed a #14 AWG or #12 AWG solid copper wire through the grounding eye on the elbow, twist it tight, and connect it to ground using an appropriate connector. Clean and lubricate the 200 amp interface on the LINK-C connector. Ground, then install the desired mating product onto the 200 amp interface according to its specific installation instructions. Ground the cable: If using concentric neutral cable, twist the concentric neutral wires together and connect to ground using an appropriate connector. If 20MA or 21MA grounding devices are used, connect their ground lead to ground using a suitable connector. For three-phase installations, all grounds from all three phases must be tied to a common ground point.

  8. Refer to Operating Instructions

    For operation of the LINK-C connector and any 200 ampere mating products, refer to their respective applicable operating instructions.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.