ABB Installation Products 3701A3(1)-H 200 Amp, 35kV Loadbreak Bushing Insert, Includes internal torquing feature using 200AT…
UPC: 783786423439
Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV, 200 Amp loadbreak rated for single-phase and three-phase applications
- Meets ANSI/IEEE Standard 386 with 21.1kV phase-to-ground and 36.6kV phase-to-phase voltage ratings
- 150kV BIL, 50kV AC one-minute withstand, and 103kV DC 15-minute withstand ratings
- Internal torquing feature compatible with ABB 200AT Assembly Tool for precise installation
- Includes black vent ring for pressure relief and moisture management in harsh environments
Specifications
Application | 35 kV, 200 Amps |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -4 F |
Temperature Rating, Minimum | -20 C |
Type | Bushing Insert |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.5000 L |
Package Weight (Metric) | 1.5880 kg |

150-TB-2
15/25kV, T-Splice 6-3/4 inch Long Bail Assembly, Made of Stainless Steel, Used for Assisting Cable to Transformer Connections. Non-Current Carrying. The 150TB2 bailing assembly kit consists of a modified hold down bail for securing Elastimold® tee splice K150T to a K150DP Deadbreak insulating plug. This assembly provides positive hold down force between the tee splice and the insulating plug.
K1601-PC-T1R-H
15/25kv, Long Shank Well with Bail Tabs and With Replaceable Well Stud (9-1/4 inch Bushing Shank Length), H option
675ETPSP
900 Amp, 15kV, Loadbreak Elbow Tap Plug, Factory assembled Stud, which is not field removable. Copper.
750SOPS
35 kV, 600 Series Deadbreak Insulated Parking Bushing with Stud and Universal Bracket and EyeBolt, Stand-Off Plug. Length 5.062 inch, Widest Diameter 3 inch. Epoxy.
775ETPSP
35kV, 900Amp, Deadbreak/Loadbreak Elbow Tap Plug, use 600ATM assembly tool. Factory assembled Stud, which is not field removable.
35MTGA-HB500-3
2 Hole Spade for MTG, includes Spade contact, ground strap and rain cap. Cable Insulation Diameter 1.095 inch to 1.240 inch. Conductor Size KCMIL Stranded 500 /Solid 600.Frequently Asked Questions
What is the voltage rating of the 3701A3(1)-H?
The device has a voltage rating of 35 kilovolts (kV).
What is the current rating of the bushing insert?
The bushing insert supports a continuous current rating of 200 Amperes (A).
Does the insert include a torquing feature?
Yes, the 3701A3(1)-H includes an internal torquing feature designed for use with the 200AT Assembly Tool.
What is the purpose of the black vent ring?
The black vent ring provides pressure relief and moisture management to maintain dielectric integrity during operation.
Is the 3701A3(1)-H compatible with standard bushing wells?
Yes, the loadbreak bushing insert is designed for compatibility with standard bushing wells in medium-voltage systems.
How to Install the 3701A3(1)-H Loadbreak Bushing Insert
Instructions for installing the 3701A3(1)-H Loadbreak Bushing Insert into apparatus bushing wells.
Estimated time: 30m
Tools needed:
Screwdriver (for grounding wire loop), Wire strippers (for grounding wire)
Supplies needed:
Lubricant (supplied), Copper wire (No. 14 AWG or equivalent), Suitable connector (for system ground), Insulated cap or grounding elbow connector (if not immediately mating)
- Prepare the bushing insert and apparatus
DANGER: All apparatus must be de-energized before proceeding. Inspect the apparatus bushing well to ensure it is dry and free from contaminants. Remove the protective shipping cap from the bushing insert. Lubricate the bushing well interface area of the bushing insert with the supplied lubricant. DO NOT SUBSTITUTE lubricant.
- Install the bushing insert
Place the lubricated portion of the bushing insert into the apparatus bushing well. Hand tighten the bushing insert in a clockwise direction until it bottoms.
- Connect the electrostatic grounding wire
Push a length of copper wire (No. 14 AWG or equivalent) through one of the grounding tabs on the bushing insert. Make a small loop and twist it tight, taking care not to damage the grounding tab. Connect the free end of the electrostatic grounding wire to the system ground using a suitable connector. Ensure the grounding wire does not contact the bushing interface or interfere with nearby components.
- Complete the installation and mating
Thoroughly wipe the bushing insert and mating product interface clean of any contaminants and lubricate with the supplied lubricant. Install the mating products to the bushing insert following their respective instructions. If the bushing insert is not to be immediately mated, replace the shipping cover. Do not energize or submerge the apparatus with the shipping cap on; it is for protection only and is not insulated or watertight.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.