Contact for Pricing
Overview
- 35kV voltage class, 900A continuous current rating
- Deadbreak/loadbreak functionality for energized operations
- Factory-assembled, non-field-removable stud for secure connections
- Meets ANSI/IEEE Standard 386 for single-phase applications
- Compatible with 600ATM assembly tool for precise torque control
Specifications
Application | 35 kV, 900 Amps |
Material | Copper |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Elbow Tap Plug |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

SPM-24L
Service Post Connector - Two Wire Type 4 STR Service Post Connectors is used for connecting one or two conductors. Made from high copper content hard-drawn rod. Lay-in feature makes them excellent for continuous loop grounding and bonding. Used to ground to bar or plate. Suitable for direct burial in earth or concrete.
54143BT
Copper Blank Tongue Lug, Standard Barrel, Peep Hole, Max 35kV, Wire Size #2 AWG, Tin Plated, Die Code 33, Die Color Code Brown
ABP 4350-1/2 RLKIT
Aluminum Overhead Transformer Eyebolt Multi-Tap Set-Screw Connector Kit. Includes (1) Right Hand Bar, (2) Left Hand Bars and (3) Boots. Connector - Length 5 Inches, Stud Size 1/2 inch Diameter x 4 inch long, Cable Range #12-350 kcmil, Outlets 4. Includes (3) Black PVC Boot, 5/8-18 x .937 inch long Screws, Tin Plated Copper Rod Pins 1/2 x 4.907 inch.
PTL 1000-18 N 90
Aluminum Compression Pin Terminal - PT Series, conductor size Aluminum - 954 and 1000 Stranded kcmil, 795 (26/7), 954 (45/7) ACSR, installing dies 140H, 301, 342, 724, 1 1/2. Solid Copper Pin 7/8 inch Diameter, Length 20-11/32 inch before Assembly, Diamond Knurled on One End. Other End of Pin is Silver Brazed to 2-Hole Tin Plated Copper NEMA Lug with 90 Degree Bend. Pad 1-23/32 inch wide x 3-1/8 inch long x 1/4 inch thick. Two Inline 9/16 inch holes on 1-3/4 inch center.
27109-HM
Copper Two Hole Lug with 1/2 Inch Copper Rod Crimped On, Overall Length 12.540 Inch, Lug Body is 5.50 Inches Long, Pad is 1.25 Inch Wide X 3.00 Inch Long. Holes are 1.750 Inch Center to Center. Rod has 8 Degree Down Bend and a 80 Degree Up Bend. 1/2 Inch Stainless Steel Hardware (2) Bolts, (4) Flat Washers, (2) Lock Washers, (2) Nuts Assembled on Lug
AL-1000-4-NTNV
Tin Plated Aluminum 4-Hole NEMA Lug, 1000 kcmil Conductor Size, Pre-filled with compound and Brown Capped. Length 10-5/8 inch. Pad 3 inch wide x 4 inch long. End of Barrel is Tapered. Installing Dies 1, 3.4, 161, 725, 161R. Conductor Sizes 954-100 MCM AL-CU, 795 (26/7), 954 (45/7) ACSR. Four 9/16 inch Holes on 1-3/4 inch Centers.
01301230
Locking Contact Pin and Crimp Barrel Assembly for Wire Size #1 Stranded AWG, 1/0 Solid or Compact AWG. Assembly consists of Stainless Steel Nose, Copper Locking Pin - Length 2 inch, Protective Cap, Aluminum Crimp Barrel - Length 2-3/16 inch and Disc Spring. Widest Diameter 5/8 inch.Frequently Asked Questions
How to order the 775ETP with a loose stud?
To order the plug with a loose stud, add the suffix "S" to the part number.
What tool is required for 775ETP installation?
The 775ETP is installed using a 600ATM assembly tool.
What products are compatible with the 775ETP?
The 775ETP mates with products such as 755BLR, 755BE, 375DRG, 376DRG, 375ESA-XX, 375LR, and 370GLR.
What is the voltage class and phase rating?
The 775ETP is rated for 35kV voltage class and single-phase (1Ø) applications only.
What is the maximum phase-to-ground operating voltage?
The maximum phase-to-ground operating voltage for the 775ETP is 21.1kV.
What is the maximum phase-to-phase voltage?
The maximum phase-to-phase voltage for the 775ETP is 36.6kV.
What is the Basic Impulse Level (BIL)?
The Basic Impulse Level (BIL) is 150kV, based on a 1.2 x 50 microsecond wave.
What are the 200 Amp loadbreak interface ratings?
The loadbreak interface is rated for 200 Amp continuous and loadbreak, with a 10kA Sym 10 Cycles momentary rating.
What are the 900 Amp deadbreak interface ratings?
The deadbreak interface is rated for 900 Amp continuous, with a 25kA Sym 10 Cycles momentary rating.
Can the loadbreak interface be operated energized?
Yes, the loadbreak interface is specifically designed for energized operation.
How to Install the LINK-C Deadbreak Cam Link Operable Connector System
This guide provides step-by-step instructions for the safe and proper installation of the LINK-C 600 amp deadbreak cam link operable connector system, including mounting, wiring, and grounding procedures.
Estimated time: 2h
Tools needed:
Hot stick, Torque wrench, Suitable tool for 1 inch hex (e.g., socket wrench), 600ATM Operating Tool, Wire strippers
Supplies needed:
ELASTIMOLD supplied lubricant, #14 AWG or #12 AWG solid copper wire, Appropriate grounding connector
- Perform Initial Checks and Safety Precautions
WARNING: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Inspect all parts for damage, rating, and compatibility with mating parts. Ensure all required tools are at hand and maintain cleanliness. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.
- Install the 600 Amp Elbow onto the Cable
Install the 600 amp elbow onto the cable according to the installation instructions supplied with the elbow. Ensure it will align with the stand-off plug.
- Clean, Lubricate, and Install Bushing Extender
Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender with ELASTIMOLD supplied lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM into the retainer contact and engage the internal hex broach.
- Secure Retainer Contact to Apparatus Bushing
Insert the retainer contact into the bushing extender and thread it into the apparatus bushing. Use a suitable tool applied to the 1 inch hex portion of the 600ATM and torque to 50-60 ft-lbs.
- Clean, Lubricate, and Install Elbow onto Epoxy Standoff Plug
Clean and thoroughly lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow with ELASTIMOLD supplied lubricant. Install the elbow onto the epoxy standoff plug. Insert the 600ATM into the retainer contact and engage the internal hex broach.
- Secure Retainer Contact to Epoxy Standoff Plug
Insert the retainer contact into the 600 amp elbow through the hole in the compression lug. Thread it into the epoxy standoff plug using a suitable tool applied to the 1 inch hex portion of the 600ATM and torque to 50-60 ft-lbs.
- Install Alignment Bracket
Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with supplied hardware, torquing alternating sides until clamp tabs are flush and tight.
- Position and Secure Elbow in Alignment Bracket
Position the elbow in the alignment bracket so the elbow cuff is lined up evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket with supplied hardware, torquing alternating sides until clamp tabs are flush and tight. Ensure the elbow clamp notch faces the cable entrance of the elbow.
- Clean, Lubricate, and Insert Link
Clean and thoroughly lubricate both 600 ampere interfaces of the Link with ELASTIMOLD supplied lubricant. Align the Link to be perpendicular to the switch faceplate when inserted into the bushing extender and elbow. Insert the Link into the bushing extender and elbow, ensuring both lever arms are on the inside of the alignment bracket legs.
- Engage Link Pivot and Roller Pins
Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, move the lever arms downward using a hot stick eye, engaging the roller pin and moving the Link inward. Continue moving lever arms until perpendicular to the alignment bracket leg.
- Ground the Elbow and Install Mating Product
Ground the elbow by feeding a #14 AWG or #12 AWG solid copper wire through the grounding eye, twisting it tight, and connecting it to ground. Clean and lubricate the 200 amp interface on the Link. Ground, then install the desired mating product on the 200 amp interface according to its supplied installation instructions.
- Ground the Cable
If using concentric neutral cable, twist the concentric neutral wires together and connect to ground using an appropriate connector. If using 20MA or 21MA grounding devices, connect the ground lead from the device to ground using a suitable connector. For three-phase installations, tie all grounds from all three phases to a common ground point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.