ABB Installation Products 656CETP-M0360-DRG 15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter…
UPC: 075114102216
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV rated for medium-voltage applications
- 600 Amp current-carrying capacity
- Supports cable insulation diameter 1.370 inch to 1.630 inch
- Includes aluminum compression lug for 650/750 kcmil or 400 mm² conductors
- Kit includes bus, stud, cable adapter, and insulated cap
Specifications
Amperage Rating | 600 A |
Application | 600 Amps, 15kV Connector |
Color | Black |
Conductor Range | 650 kcmil , 750 to 800 kcmil |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Special Features | Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | ComboT Elbow |
Voltage Rating | 15 kV |
Width | 13.31 in |
Width | 338.074 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K655L3-LM0360
15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.
656CETP-L0330-DRG
15kV, 600 Amp Combo T. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 500 kcmil or Compacted Solid 600 kcmil. Includes Insulated Cap.
656CETP-K5330-SG3
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
656CETP-L0270-DRG
15kV, 600 Amp, Combo T Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation 1.180-1.465 inches. Aluminum Connector Type, Connector Size 4/0 Stranded/Compressed or 500 Compact/Solid. With Insulated Cap. With Test Point.
656CETP-K0330-DRG
15kV, 600 Amp Combo T. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 500 kcmil or Compacted Solid 600 kcmil. Includes Insulated Cap.
656CETP-J5300
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 150.
656BCETP
600 Amp, 15kV, ComboT Elbow / Reducing Tap Plug (Aluminum) with Test Point - Basic Combo T Elbow with Bus and Stud.
656CETP-H0270-S
15kV, 600 Series ComboT Elbow with 200 Amp Reducing Tap Plug, Stud, Cable Adapter and Lug Kit with Test Point and Seal. Cable Insulation Diameter 0.850 - 1.050 inches (21.6-26.7mm). Aluminum Compression Lug. Conductor Size 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Lug, Tube of Lubricant, Cable Adapter, Crimp Chart and Installation Instructions.Frequently Asked Questions
What is the primary safety precaution for ComboT installation?
The system must be de-energized before initiating any ComboT installation. Always refer to the complete instruction sheet.
What is the primary safety precaution for ComboT installation?
The system must be de-energized before initiating any ComboT installation. Always refer to the complete instruction sheet.
What are the voltage ratings for 15 kV CETP?
The 15 kV CETP has a max phase-to-ground operating voltage of 8.3 kV and a max phase-to-phase operating voltage of 14.4 kV.
What stud size is used for ComboT assembly?
The ComboT utilizes a standard 5/8 in–11 stud that threads into the equipment bushing for assembly.
What are the continuous current ratings for CCP/CBW?
The continuous current ratings for CCP and CBW are 600 A or 900 A.
What are the continuous current ratings for CETP?
The CETP has continuous current ratings of 600 A for deadbreak and 200 A for loadbreak, or 900 A for deadbreak and 200 A for loadbreak.
What is the loadbreak switching current for CETP?
The loadmake/loadbreak switching current for the CETP is 200 A.
How much does the ComboT reduce stack height?
Each combination elbow/connecting plug reduces the stack height by 2.67 inches.
What is the maximum operating voltage for CCP/CBW?
The maximum phase-to-phase operating voltage for CCP/CBW is 28.0 kV, with a phase-to-ground operating voltage of 16.2 kV.
What is the maximum operating voltage for CCP/CBW?
The maximum phase-to-phase operating voltage for CCP/CBW is 28.0 kV, with a phase-to-ground operating voltage of 16.2 kV.
How to Install 655/656/675/676CETP Deadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of 655/656/675/676CETP Deadbreak Elbow Connectors, including cable preparation, lug crimping, and connection to high voltage apparatus. Ensure all safety warnings are observed.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Measuring tape, Wire brush (for aluminum conductors), Crimping tool (for compression lugs), 600AT or 600ATM assembly tool, Hotstick, Suitable sensing device (for voltage test)
Supplies needed:
655/656/675/676CETP Elbow, Cable Adapter, Compression Lug, Lubricant (supplied with connector), Vinyl plastic tape, Tape retainer (if fabric tape shield), Tape marker, Ground wire (min. No. 14 AWG Copper), Suitable grounding connector, HV insulated cap(s) or connector(s) (for shipping covers), Silicone grease (for test point cap)
- Perform Initial Safety Checks and Product Inspection
DANGER: Ensure all apparatus is de-energized during installation or removal. Do not touch or move energized products. Inspect all parts for damage, correct rating, and compatibility with mating parts. Check package contents for completeness and ensure all required tools are at hand. Read all instructions before starting.
- Prepare the Cable for Connection
Position the cable with enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for 24” (610mm) or up to the bent back concentric neutral wires. Remove the outer jacket to the specified dimension. Fold back shield wires. Depending on cable type, remove the flat metallic tape shield and secure with vinyl plastic tape, or remove fabric tape shield and install tape retainer and tape marker, or remove longitudinally corrugated shield and install tape marker, or remove semi-con shield and install tape marker. If using UNISHIELD® or lead sheath cable, refer to 10TL cable shield adapter instructions for preparation and grounding. Do not cut or nick the cable insulation.
- Prepare Cable Insulation and Install Cable Adapter
Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker. Remove the protruding cable insulation by cutting it even with the end of the cable adapter, ensuring the exposed conductor length is 4-3/8” to 4-11/16” (111mm-119mm). Do not cut or nick the cable adapter or conductor.
- Install the Compression Lug
For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the 'Check Dimension' before crimping; it should be less than 6-1/2” (165mm). Crimp the compression lug following the supplied crimping instructions, locating the first crimp on the end closest to the cable adapter. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be 6-1/2” to 7-1/4” (165mm-184mm).
- Install the Elbow onto the Cable Adapter
Lubricate the cable adapter and the inside of the elbow cable entrance with the supplied lubricant. Install the elbow onto the cable adapter until it cannot advance further. Verify that the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.
- Connect the Elbow to the Mating Product
WARNING: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove any protective caps from the elbow and the mating part. Install the stud into the apparatus by hand until fully seated. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Push the elbow onto the mating part. For products dated September 30, 2013 or earlier, use a 600AT assembly tool to torque the contact assembly until the torque limiter ratchets (19 to 25 ft/lbs). For products dated October 1, 2013 or later, use a 600ATM assembly tool to tighten the contact assembly to 50-60 ft/lbs torque, but DO NOT EXCEED 60 ft/lbs.
- Ground the Cable Shield
Insert one end of a ground wire (with ampacity at least equivalent to No. 14 AWG Copper) through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded according to the instructions supplied with any grounding device used, or via an alternate method if no device is present. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.
- Connect Additional Loadbreak Interface Components (Optional)
Clean and lubricate the entire loadbreak interface and either a DR(G), ESA, GLR, or LR of the appropriate voltage class with the supplied or ELASTIMOLD® approved lubricant. Install the DR(G), ESA, GLR, or LR to the tap plug interface following the instructions supplied with those specific products.
- Verify Full Seating of Assembly
Confirm the complete assembly of an insulated cap or elbow by ensuring no portion of the colored interface sleeve is visible when viewed from the side. This indicates full seating.
- Perform Voltage Test (656CETP only)
If applicable, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device and not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Contamination or incorrect equipment can give a false 'no voltage' indication; treat the elbow as energized until confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.