- 15kV voltage class with 8.3kV phase-to-ground and 14.4kV phase-to-phase ratings
- Supports 1.180" to 1.465" cable insulation diameter and 500-600 kcmil conductors
- 200A loadbreak and 600A deadbreak interface with 10kA symmetrical momentary rating
- Hollow-bore design enables visual validation of compression lug positioning
- IEEE 386 color-coded PBT interface for improved visibility and seating indication
Specifications
Amperage Rating | 600 A |
Application | 600 Amps, 15kV Connector |
Color | Black |
Conductor Range | 500 kcmil , 600 kcmil |
Connection Type | Compression Lug |
Current Rating | 600 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Aluminum |
Material | Housing - EPDM-Rubber |
Series | 600 Series ComboT |
Size | 1.180-1.465 inch (cable insulation diameter), 500-600 kcmil (conductor size) |
Size | Cable Insulation Diameter 1.180 - 1.465 inches |
Special Features | Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | ComboT Elbow |
Voltage Rating | 15 kV |
Voltage Rating | 15kV |
Width | 13.31 in |
Width | 338.074 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

655LRTP-L0330
600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
656CETP-K5330-SG3
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
656CETP-L0270-DRG
15kV, 600 Amp, Combo T Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation 1.180-1.465 inches. Aluminum Connector Type, Connector Size 4/0 Stranded/Compressed or 500 Compact/Solid. With Insulated Cap. With Test Point.
656CETP-K0330-DRG
15kV, 600 Amp Combo T. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 500 kcmil or Compacted Solid 600 kcmil. Includes Insulated Cap.
656CETP-J5300
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 150.
656BCETP
600 Amp, 15kV, ComboT Elbow / Reducing Tap Plug (Aluminum) with Test Point - Basic Combo T Elbow with Bus and Stud.
656CETP-H0270-S
15kV, 600 Series ComboT Elbow with 200 Amp Reducing Tap Plug, Stud, Cable Adapter and Lug Kit with Test Point and Seal. Cable Insulation Diameter 0.850 - 1.050 inches (21.6-26.7mm). Aluminum Compression Lug. Conductor Size 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Lug, Tube of Lubricant, Cable Adapter, Crimp Chart and Installation Instructions.Frequently Asked Questions
What is the maximum operating voltage for 15 kV CETP?
The maximum phase-to-ground operating voltage for 15 kV CETP is 8.3 kV, and phase-to-phase is 14.4 kV.
What is the torque specification for CCP installation?
For CCP installation, the 600ATM and BIP should be torqued to 50 to 60 ft.-lbs.
What is a critical safety step before installation?
The system needs to be de-energized before initiating any installation. Always refer to the complete instruction sheet.
What is the continuous current rating for CETP?
The continuous current rating for CETP is 600 A for 600 A DB, 200 A for 200 A LB, and 900 A for 900 A DB.
What is the loadbreak switching current for CETP?
The loadmake/loadbreak switching current for CETP is 200 A.
What is the voltage class for ComboT connecting plugs?
ComboT connecting plugs and bushing wells have a voltage class of 15/25/28 kV.
How much does the ComboT reduce stack height?
Each combination elbow/connecting plug reduces the stack height by 2.67 inches.
What is the maximum operating voltage for CCP/CBW?
The maximum phase-to-ground operating voltage for CCP/CBW is 16.2 kV, and phase-to-phase is 28.0 kV.
What stud size is used for ComboT assembly?
The ComboT utilizes a standard 5/8 in–11 stud that threads into the equipment bushing.
What stud size is used for ComboT assembly?
The ComboT utilizes a standard 5/8 in–11 stud that threads into the equipment bushing.
How to Install 655/656/675/676CETP Deadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of 655/656/675/676CETP Deadbreak Elbow Connectors, designed for high voltage apparatus connections and loadbreak taps.
Estimated time: 1h 30m
Tools needed:
600AT or 600ATM assembly tool, Wire brush, Hotstick, Suitable voltage sensing device, Wire strippers, Crimping tool, Measuring tape
Supplies needed:
Kit components (Elbow, Cable Adapter, Compression Lug), Lubricant (supplied), Vinyl plastic tape, Wire (min. No. 14 AWG Copper), Suitable grounding connector, Silicone grease
- Position and Cut Cable
Position the cable in its final assembled location, ensuring enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. DANGER: Ensure all apparatus is de-energized before starting any work.
- Clean Cable Outer Surface
Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent-back concentric neutral wires.
- Prepare for Grounding Device or Jacket Seal (If Applicable)
If using a 20MA or 21MA grounding device or 600ECS Jacket Cable Seal, refer to their specific installation instructions for cable outer jacket removal, shield connection, and grounding. Otherwise, proceed with the following instructions for these procedures.
- Prepare Cable Jacket and Shield
Remove the outer jacket to the specified dimension. Fold back shield wires. For flat metallic tape shield, remove it and secure with vinyl plastic tape. For fabric tape shield, remove it and install a tape retainer and tape marker. For longitudinally corrugated shield, remove it and install a tape marker. For semi-con shield, remove it and install a tape marker, ensuring not to cut or nick the cable insulation. If using UNISHIELD® or lead sheath cable, refer to 10TL cable shield adapter instructions for preparation and grounding.
- Bevel, Clean, Lubricate, and Install Cable Adapter
Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation (using supplied lubricant), always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.
- Expose Conductor
Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The exposed conductor length must be 4 3/8 to 4 11/16 inches (111mm to 119mm). If not, redo the assembly.
- Crimp Compression Lug
For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it. Measure the 'Check Dimension' (must be less than 6 1/2 inches / 165mm) before crimping. Crimp the lug following its supplied instructions. Wipe off all excess inhibitor. The distance from the end of the lug to the cable adapter after crimping must be 6 1/2 to 7 1/4 inches (165mm to 184mm). If dimensions are incorrect, redo the assembly.
- Lubricate and Install Elbow
Lubricate the cable adapter and the inside of the elbow cable entrance with the supplied lubricant. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.
- Prepare Mating Products and Install Stud
DANGER: Do not connect or disconnect mating products while energized, and do not energize while disconnected. Remove protective caps from the elbow and the mating part. Install the stud into the apparatus by hand until fully seated. Clean and lubricate both the elbow and the mating part with the supplied lubricant, keeping surfaces clean.
- Connect Elbow to Mating Part
Push the elbow onto the mating part. For products dated September 30, 2013 or earlier, use the 600AT assembly tool to engage the hex broach and torque the contact assembly until the torque limiter ratchets (19-25 ft/lbs). For products dated October 1, 2013 or later, use the 600ATM assembly tool and tighten to 50-60 ft/lbs torque. DO NOT EXCEED 60 FOOT POUNDS TORQUE.
- Ground Cable Shield
Insert one end of a wire (min. No. 14 AWG Copper) through the grounding eye and twist to form a small loop, avoiding damage to the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded according to the instructions supplied with the grounding device, or via an alternate method if no device is used. Waterproof the cable jacket to prevent moisture entry.
- Install Loadbreak Interface (Optional)
Clean and lubricate the entire loadbreak interface and either a DR(G), ESA, GLR, or LR of the appropriate voltage class with the supplied lubricant. Install the DR(G), ESA, GLR, or LR to the tap plug interface following their respective instructions.
- Verify Seating and Perform Voltage Test
Verify complete assembly by ensuring no portion of the colored interface sleeve is visible from the side. To test voltage on 656CETP, remove the test point cap with a hotstick (peel off at an angle). WARNING: Use a suitable sensing device for capacitive test points; do not use conventional voltage measuring equipment. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means to prevent serious injury. After testing, clean and lubricate the cap's inside surface with silicone grease and replace it.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.