ABB - Installation Products 655CETPM0380 - 600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.370 inch to 1.630 inch.

ABB Installation Products 655CETPM0380 600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug, No Test…

UPC: 783786084128


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 600 Amp, 15kV Combo T Elbow Reducing Tap Plug (SKU: 655CETPM0380) is designed for reliable electrical connections in medium voltage applications. It features an aluminum construction for durability and conductivity. The tap plug is engineered to accommodate cable insulation diameters ranging from 1.370 inches to 1.630 inches, ensuring a secure fit for specified cable sizes. This specific model includes a stud and cable adapter for versatile installation, but notably omits a test point. The UNSPSC code for this product is 39121421. It is a component within the ABB Installation Products catalog. The reducing tap plug facilitates efficient power distribution by providing a secure connection point for branch circuits or equipment. Its design prioritizes robust electrical contact and mechanical integrity within its operational parameters. The 600 Amp rating signifies its capacity for high current loads, and the 15kV rating indicates its suitability for medium voltage systems. This product is essential for utility, industrial, and commercial power distribution networks where reliable and safe connections are paramount. The absence of a test point simplifies the connector design for specific installation requirements.
  • 600 Amp current rating
  • 15kV voltage rating
  • Aluminum construction
  • Accommodates cable insulation diameters from 1.370" to 1.630"
  • Includes stud and cable adapter, no test point

Specifications

Amperage Rating
600 A
Application
600 Amps, 15kV Connector
Color
Black
Conductor Range
700 to 750 kcmil , 900 kcmil
Connection Type
Combo T Elbow Reducing Tap Plug
Current Rating
600 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
ComboT
Size
1.370 inch to 1.630 inch
Special Features
Reducing Tap Plug with Stud, Cable Adapter, and Lug
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
ComboT Elbow
Voltage Rating
15 kV
Width
13.31 in
Width
338.074 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
6.5700 L
Package Weight (Metric)
2.9800 kg
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil.

656ETP-M0380-DRG

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
900 Amp, 15kV, ComboT Elbow / Reducing Tap Plug, Copper Connector, with Test Point.

676BCETP

900 Amp, 15kV, ComboT Elbow / Reducing Tap Plug, Copper Connector, with Test Point.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Shrink-Fit Jacket Seal Kit.

655CETPN0410DRGS

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Shrink-Fit Jacket Seal Kit.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Shrink-Fit Jacket Seal Kit.

655CETPM0380DRGS

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Shrink-Fit Jacket Seal Kit.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000.

655CETPN0410DRG

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Copper, Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Shrink-Fit Jacket Seal Kit.

655CETPM2380DRGS

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Copper, Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Shrink-Fit Jacket Seal Kit.
15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit.

K656CETP

15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit.

Frequently Asked Questions

What is a critical safety step before ComboT installation?

The system must be de-energized before initiating any ComboT installation. Always refer to the complete instruction sheet.

What is the torque specification for CCP bus insertion?

For CCP installation, the 600ATM should be torqued to 50 to 60 ft.-lbs.

What connector materials are available for ComboT?

ComboT connectors are available in universal aluminum, copper, or bi-metal options.

Can ComboT connectors include a test point?

Yes, ComboT connectors are available with or without a capacitive test point.

How much does the ComboT reduce stack height?

Each combination elbow/connecting plug reduces stack height by 2.67 inches.

What tools are needed for ComboT installation?

The ComboT installs with standard assembly tools and uses a standard 600 or 900 series stud.

How does the 25 kV reducing tap prevent flashover?

The 25 kV reducing tap includes vents to prevent partial-vacuum flashover.

What are the voltage ratings for CETP connectors?

CETP connectors are available in 15 kV and 25 kV voltage classes. The maximum phase-to-ground operating voltage is 8.3 kV for 15 kV and 15.2 kV for 25 kV.

What is the continuous current rating for CETP connectors?

CETP connectors have continuous current ratings of 600 A for deadbreak and 200 A for loadbreak, or 900 A for deadbreak and 200 A for loadbreak.

What is the loadbreak switching current for CETP?

The loadmake/loadbreak switching current for CETP connectors is 200 A.

How to Install 655/656/675/676CETP Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation, cable preparation, and connection of 655/656/675/676CETP Deadbreak Elbow Connectors to high voltage apparatus, including grounding and voltage testing.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Torque wrench, 600AT assembly tool (or 600ATM assembly tool), Hotstick, Suitable sensing device (for capacitive test points), Wire brush (for aluminum conductors), Suitable connector (for grounding wire)

Supplies needed:

Elbow (655/656/675/676CETP), Cable Adapter, Compression Lug, Lubricant (supplied with product), Vinyl Plastic Tape, Tape marker (various types depending on shield), Tape retainer (for fabric tape shield), 10TL cable shield adapter (if needed for UNISHIELD® or lead sheath cable), No. 14 AWG Copper wire (or equivalent) for grounding, Silicone grease (for test point cap), DR(G), ESA, GLR, or LR (mating loadbreak products, if applicable), HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Prepare for Installation and Position Cable

    DANGER: Ensure all apparatus are de-energized during installation. Inspect package contents and all components for damage, rating, and compatibility. Position the cable in its final assembled position with enough slack to provide adequate clearance for removing the elbows. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product.

  2. Clean and Prepare Cable Outer Jacket and Shield

    Clean the outer surface of the cable for 24” (610mm) or up to the bent back concentric neutral wires. Remove the outer jacket to the specified dimension. Fold back shield wires. Depending on the cable shield type (e.g., flat metallic tape, fabric tape, longitudinally corrugated, semi-con), follow specific instructions for shield removal and installation of tape markers or shield adapters (e.g., 10TL for UNISHIELD® or lead sheath cable). Do not cut or nick the cable insulation.

  3. Prepare Cable Insulation and Conductor

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and lubricate the cable insulation (lubricant supplied), always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker. Remove the protruding cable insulation even with the end of the cable adapter. Verify the exposed conductor length is 4 3/8”–4 11/16” (111mm–119mm). Do not cut or nick the cable adapter or conductor.

  4. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it. Measure the 'Check Dimension' (must be less than 6 1/2” (165mm)) before crimping. Crimp the compression lug according to its supplied crimping instructions. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. Verify the distance from the end of the compression lug to the cable adapter is 6 1/2”–7 1/4” (165mm–184mm) after crimping.

  5. Install the Elbow onto the Cable Adapter

    Lubricate (lubricant supplied) the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Make sure the cable adapter is still flush with the tape marker; reposition if not. Remove the tape marker.

  6. Connect Elbow to Mating Product

    DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from the elbow and the mating part. Install the stud into the apparatus by hand until fully seated. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Push the elbow onto the mating part. Use the appropriate 600AT or 600ATM assembly tool to engage the contact assembly with the stud and torque to the specified value (19-25 ft/lbs for 600AT, 50-60 ft/lbs for 600ATM, do not exceed 60 ft/lbs).

  7. Ground the Cable Shield

    Insert one end of a wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop. Do not damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; ground according to the instructions supplied with the grounding device or through an alternate method. Waterproof the cable jacket at this point to prevent moisture from entering the cable.

  8. Install Mating Connector (if applicable) and Verify Seating

    Clean and lubricate (lubricant supplied) the entire loadbreak interface and either a DR(G), ESA, GLR, or LR of the appropriate voltage class. Install the DR(G), ESA, GLR, or LR to the tap plug interface following the instructions supplied with each of these products. Complete assembly of an insulated cap or elbow is indicated by no portion of the colored interface sleeve being visible when viewed from the side.

  9. Perform Voltage Test (for 656CETP with test point)

    WARNING: The voltage test point is a capacitance device; it is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Remove the test point cap with a hotstick, peeling off at an angle. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. WARNING: Treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.