ABB - Installation Products 655CETPN0410DRG - 600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000.

ABB Installation Products 655CETPN0410DRG 600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and…

UPC: 783786342853


Documents & Media
BrochureInstallation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 600 Amp, 15kV Combo T Elbow Reducing Tap Plug Kit (SKU: 655CETPN0410DRG) is designed for reliable electrical connections in medium-voltage applications. It facilitates a reducing tap connection for compressed stranded aluminum conductors up to 1000 kcmil. The kit includes a cable adapter, lug, and insulated cap, ensuring a complete and secure termination. Specifically engineered for cable insulation diameters ranging from 1.515 inches to 1.780 inches, this kit provides a precise fit for specified cable sizes, crucial for maintaining electrical integrity and preventing premature failure. The absence of a test point simplifies the installation process while maintaining essential safety and performance standards for 15kV systems. This component is suitable for utility, industrial, and commercial power distribution networks where robust and dependable connections are paramount. The aluminum construction offers good conductivity and corrosion resistance. ABB's commitment to quality in their Installation Products division ensures this tap plug kit meets stringent operational requirements.
  • 600 Amp, 15kV rating for medium-voltage applications
  • Reducing tap plug configuration for 1000 kcmil compressed stranded aluminum conductors
  • Accommodates cable insulation diameters from 1.515" to 1.780"
  • Complete kit includes cable adapter, lug, and insulated cap
  • Aluminum construction for reliable conductivity and durability

Specifications

Amperage Rating
600 A
Application
600 Amps, 15kV Connector
Color
Red
Color
Black
Conductor Range
1000 kcmil
Connection Type
Compression Lug
Current Rating
600 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Material
Aluminum
Series
600 Series
Size
Cable Insulation Diameter 1.515 inch to 1.780 inch
Special Features
Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
ComboT Elbow
Voltage Rating
15 kV
Width
13.31 in
Width
338.074 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15kV, Deadbreak RetroFit Cam-Op Connector Kit with Insulated Cap, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

655LINKCLRN0410ADRG

600 Amp, 15kV, Deadbreak RetroFit Cam-Op Connector Kit with Insulated Cap, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Copper, Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Shrink-Fit Jacket Seal Kit.

655CETPM2380DRGS

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Copper, Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Shrink-Fit Jacket Seal Kit.
15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit.

K656CETP

15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit.
15/25kV, 600 Amp, no test point, Combo T Elbow Reducing Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

K655CETPL5270

15/25kV, 600 Amp, no test point, Combo T Elbow Reducing Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, Conductor Size #4 Solid/Compact, Bi-Metal Compression Lug. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.

162LR-C5190-SG3

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, Conductor Size #4 Solid/Compact, Bi-Metal Compression Lug. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.

756LR-L0270-S

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included.

756LR-L0260-S

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included.

Frequently Asked Questions

Does the 25 kV reducing tap have a special feature?

Yes, the 25 kV Reducing tap includes vents that prevent partial-vacuum flashover.

What is the impulse withstand rating for 25 kV CETP?

For 25 kV CETP connectors, the Basic Impulse Level (BIL) impulse withstand rating is 125 kV (1.2 x 50 microsecond wave).

What is the corona extinction level for 15 kV CETP?

The corona extinction level for 15 kV CETP connectors is 11 kV at 3.0 pC sensitivity.

What is the one-minute AC withstand voltage for CCP/CBW?

For CCP/CBW connectors, the one-minute AC withstand voltage is 45 kV.

What are the voltage ratings for CETP connectors?

CETP connectors are available in 15 kV and 25 kV voltage classes. The maximum phase-to-ground operating voltage is 8.3 kV for 15 kV class and 15.2 kV for 25 kV class.

What continuous current can CETP connectors handle?

CETP connectors can handle continuous currents of 600 A or 900 A for deadbreak connections, and 200 A for loadbreak connections.

What is the stack height reduction with ComboT connectors?

Each combination elbow/connecting plug reduces the stack height by 2.67 inches, allowing for installation in smaller cabinets and tighter spaces.

What are the voltage ratings for CCP/CBW connectors?

CCP and CBW connectors have a voltage class of 15/25/28 kV. The maximum phase-to-ground operating voltage is 16.2 kV, and phase-to-phase is 28.0 kV.

What is the required torque for CCP bus installation?

During CCP installation, the 600ATM and BIP components should be torqued to 50 to 60 ft.-lbs.

What safety precaution is necessary before installation?

The system needs to be de-energized before initiating any installation of the ComboT integral separable connectors.

How to Install 655/656/675/676CETP Deadbreak Elbow Connectors

This guide provides detailed instructions for the safe and proper installation of 655/656/675/676CETP Deadbreak Elbow Connectors, ensuring fully shielded and submersible cable connections to high voltage apparatus.

Estimated time: 1h 30m

Tools needed:

600AT or 600ATM assembly tool, Crimping tool, Wire brush (for aluminum conductors), Hotstick, Suitable voltage sensing device (for capacitive test points), Wire strippers

Supplies needed:

655/656/675/676CETP Deadbreak Elbow Connector Kit (includes Elbow, Cable Adapter, Compression Lug, Lubricant), Vinyl plastic tape, Tape retainer (if using fabric tape shield), Tape marker, Ground wire (minimum No. 14 AWG Copper), Silicone grease

  1. Prepare for Installation and Ensure Safety

    DANGER: All apparatus must be de-energized during installation or removal of parts. Before beginning, verify the contents of the package are complete and undamaged, and check all components for proper fit with the cable and mating products. Gather all required tools and maintain cleanliness throughout the procedure. This product must be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Failure to follow these instructions will result in damage to the product and serious or fatal injury.

  2. Position Cable and Prepare for Cutting

    Position the cable in its final assembled location, ensuring enough slack to provide adequate clearance for removing the elbows. For concentric neutral cable, unwind the concentric neutral wires. Measure and cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.

  3. Clean Cable and Prepare for Jacket Removal

    Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent-back concentric neutral wires. If a 20MA or 21MA grounding device or 600ECS Jacket Cable Seal is being used, refer to their specific installation instructions for outer jacket removal, shield connection, and grounding. Otherwise, proceed with the following steps for cable preparation.

  4. Prepare Cable Outer Jacket and Shield

    Remove the cable's outer jacket to the dimension shown in the product documentation. Fold back the shield wires. Depending on the cable type, remove the flat metallic tape shield and secure it with vinyl plastic tape, or remove the fabric tape shield and install a tape retainer and tape marker, or remove the longitudinally corrugated shield and install a tape marker, or remove the semi-con shield and install a tape marker. If using UNISHIELD® or lead sheath cable, refer to the 10TL cable shield adapter instructions for cable preparation and grounding. Do not cut or nick the cable insulation.

  5. Bevel, Clean, Lubricate, and Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation with the supplied lubricant, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  6. Trim Cable Insulation and Verify Conductor Length

    Carefully remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor must be between 4-3/8 inches (111mm) and 4-11/16 inches (119mm). If the length is outside this range, redo the assembly.

  7. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping; this dimension should be less than 6-1/2 inches (165mm). Crimp the compression lug following the crimping instructions supplied with the lug. After crimping, wipe all excess inhibitor from the compression lug and cable adapter surface. The distance from the end of the compression lug to the cable adapter after crimping should be between 6-1/2 inches (165mm) and 7-1/4 inches (184mm). Redo assembly if dimensions are incorrect.

  8. Lubricate and Install Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance with the supplied lubricant. Install the elbow onto the cable adapter until the elbow cannot advance further. Make sure the cable adapter is still flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  9. Prepare Mating Products and Stud

    WARNING: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from the elbow and the mating part. Install the stud into the apparatus by hand until it is fully seated. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  10. Connect Elbow to Mating Part

    Push the elbow onto the mating part. For products dated September 30, 2013, or earlier, use the 600AT assembly tool to engage the hex broach in the contact assembly, insert it into the elbow interface to engage the stud, and torque the contact assembly until the torque limiter on the 600AT ratchets (19 to 25 foot-pounds torque). For products dated October 1, 2013, or later, use the 600ATM assembly tool, engage the hex broach in the contact assembly, insert it into the elbow interface to engage the stud, and tighten the contact assembly to 50-60 foot-pounds torque. DO NOT EXCEED 60 FOOT-POUNDS TORQUE.

  11. Ground the Cable Shield

    Insert one end of a piece of wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, ensuring not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded according to the instructions supplied with the grounding device. If no grounding device is used, the shield must be grounded through an alternate method. It is also recommended that the jacket of the cable be waterproofed at this point to prevent moisture from entering the cable.

  12. Install Mating Connector or Cap

    Clean and lubricate the entire loadbreak interface and either a DR(G), ESA, GLR, or LR of the appropriate voltage class with the supplied lubricant or an ELASTIMOLD® approved lubricant. Install the DR(G), ESA, GLR, or LR to the tap plug interface following the instructions supplied with each of these products. Alternatively, install an insulated cap if no further connection is needed.

  13. Verify Seating and Test Voltage (Optional)

    Confirm complete assembly of an insulated cap or elbow by ensuring no portion of the colored interface sleeve is visible when viewed from the side. For 656CETP models, the integral capacitance test point can be used to establish whether or not the circuit is energized. Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the meter that is used. Test with a suitable sensing device made for use with separable connectors manufactured with capacitive test points. Contamination, moisture, dirt, etc., around the test point or use of the wrong measuring equipment can provide a false “no voltage” indication on an energized elbow. To prevent serious or fatal injury, treat the elbow as energized until the “no voltage” test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.