Authorized ABB Distributor (Installation Products)
ABB - Installation Products 655CETPM2380DRGS - 600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Copper, Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Shrink-Fit Jacket Seal Kit.

ABB Installation Products 655CETPM2380DRGS 600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and…

UPC: 783786537679


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 655CETPM2380DRGS is a 600 Amp, 15kV Combo T Elbow Reducing Tap Plug Kit designed for high-voltage electrical applications. This kit includes a cable adapter, lug, and insulated cap, facilitating secure and reliable connections. Engineered by ABB Installation Products, this component is crucial for managing power distribution in industrial settings. It is specifically designed to accommodate cable insulation diameters ranging from 1.370 inches to 1.630 inches. For conductor sizes, it supports compressed stranded conductors from 700 to 750 kcmil and compacted solid conductors up to 900 kcmil. The inclusion of a Shrink-Fit Jacket Seal Kit ensures a robust and environmentally sealed connection, protecting against moisture and contaminants. This tap plug is a vital part of electrical infrastructure, ensuring the safe and efficient transfer of power. Its construction emphasizes durability and performance, meeting the stringent requirements of industrial power systems. The SKU 655CETPM2380DRGS signifies a precise component within ABB's extensive range of installation products, offering a reliable solution for medium-voltage applications. The absence of a test point simplifies the design for applications where direct testing is not required, focusing on secure termination and connection.
  • 600 Amp, 15kV rated for medium-voltage applications
  • Combo T Elbow Reducing Tap Plug with Stud
  • Accommodates cable insulation diameters from 1.370" to 1.630"
  • Supports compressed stranded 700/750 kcmil and compacted solid 900 kcmil conductors
  • Includes cable adapter, lug, insulated cap, and Shrink-Fit Jacket Seal Kit

Specifications

Amperage Rating
600 A
Application
600 Amps, 15kV Connector
Color
Red
Color
Black
Conductor Range
700 to 750 kcmil , 900 kcmil
Connection Type
Combo T Elbow
Current Rating
600 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Copper
Material
Housing - EPDM-Rubber
Series
655CETPM
Size
1.370 inch to 1.630 inch (Cable Insulation Diameter)
Special Features
Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
ComboT Elbow
Voltage Rating
15 kV
Width
13.31 in
Width
338.074 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size kcmil Compressed/Stranded 700/750 or Compact/Solid 900.

K655LRM2380

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size kcmil Compressed/Stranded 700/750 or Compact/Solid 900.
DISTRIBUTION BLOCK UNIPOLAR 125 A IEC AND 115 A UR

54111012

DISTRIBUTION BLOCK UNIPOLAR 125 A IEC AND 115 A UR
Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC

V-25TB

Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC
15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit.

K656CETP

15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit.
15/25kV, 600 Amp, no test point, Combo T Elbow Reducing Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

K655CETPL5270

15/25kV, 600 Amp, no test point, Combo T Elbow Reducing Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, Conductor Size #4 Solid/Compact, Bi-Metal Compression Lug. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.

162LR-C5190-SG3

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, Conductor Size #4 Solid/Compact, Bi-Metal Compression Lug. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.

756LR-L0270-S

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included.

756LR-L0260-S

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included.

Frequently Asked Questions

What is the maximum cable insulation diameter supported?

This tap plug kit supports cable insulation diameters ranging from 1.370 inches to 1.630 inches.

What conductor sizes can this kit accommodate?

It supports compressed stranded conductors from 700 to 750 kcmil and compacted solid conductors up to 900 kcmil.

What components are included in this kit?

The kit includes a cable adapter, lug, insulated cap, and a Shrink-Fit Jacket Seal Kit.

What is the voltage rating of this tap plug?

This tap plug is rated for 15kV.

What is the current rating of this tap plug?

This tap plug is rated for 600 Amps.

How to Install 655/656/675/676CETP Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 655/656/675/676CETP Deadbreak Elbow Connectors, including cable preparation, crimping, and connection to high voltage apparatus.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Wire brush (for aluminum conductor), 600AT assembly tool OR 600ATM assembly tool, Hotstick, Suitable voltage sensing device

Supplies needed:

Lubricant (supplied), Vinyl plastic tape, Tape retainer (if applicable), Tape marker (if applicable), Compression lug (supplied), Wire (min. No. 14 AWG Copper), Suitable grounding connector, Silicone grease

  1. Perform Pre-Installation Checks and Safety Procedures

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Inspect all parts for damage, rating, and compatibility. Ensure all required tools are at hand and maintain cleanliness throughout the procedure. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.

  2. Position Cable and Make Initial Cut

    Position the cable in its final assembled location, ensuring enough slack for elbow removal. For concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.

  3. Clean Cable Outer Surface

    Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent back concentric neutral wires.

  4. Prepare Cable Outer Jacket

    Remove the cable's outer jacket to the dimension shown in the product documentation. If using a 20MA, 21MA grounding device, or 600ECS Jacket Cable Seal, refer to their specific installation instructions for jacket removal, shield connection, and grounding.

  5. Prepare Cable Shield Wires

    Fold back the cable shield wires.

  6. Prepare Flat Metallic Tape Shield (if applicable)

    Remove any flat metallic tape shield and secure the remaining shield with vinyl plastic tape to the dimension shown in the product documentation.

  7. Prepare Fabric Tape Shield (if applicable)

    Remove any fabric tape shield and install a tape retainer and tape marker to the dimensions shown in the product documentation.

  8. Prepare Longitudinally Corrugated Shield (if applicable)

    Remove any longitudinally corrugated shield and install a tape marker to the dimension shown in the product documentation.

  9. Prepare Semi-Con Shield (if applicable)

    Remove any semi-con shield and install a tape marker to the dimensions shown in the product documentation. Exercise extreme caution not to cut or nick the cable insulation.

  10. Bevel, Clean, Lubricate, and Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation with the supplied lubricant, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  11. Prepare Conductor Length

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The exposed conductor length should be 4 3/8 to 4 11/16 inches (111mm to 119mm); otherwise, redo the assembly.

  12. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the lug. Measure the 'Check Dimension' before crimping; it should be less than 6 1/2 inches (165mm). Crimp the compression lug following the supplied crimping instructions. Wipe all excess inhibitor from the lug and cable adapter surface after crimping. The distance from the end of the lug to the cable adapter after crimping should be 6 1/2 to 7 1/4 inches (165mm to 184mm); otherwise, redo the assembly.

  13. Lubricate and Install Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance with the supplied lubricant. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  14. Prepare Mating Products and Install Stud

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from the elbow and the mating part. Install the stud into the apparatus by hand until it is fully seated. Clean and lubricate both the elbow and the mating part with the supplied lubricant, keeping surfaces clean.

  15. Connect Elbow to Mating Part

    Push the elbow onto the mating part. If the product is dated September 30, 2013, or earlier, use the 600AT assembly tool to engage the hex broach in the contact assembly, insert it into the elbow interface to engage the stud, and torque until the 600AT ratchets (19 to 25 foot/pounds). If the product is dated October 1, 2013, or later, use the 600ATM assembly tool, engage the hex broach, insert the contact assembly, and tighten to 50-60 foot/pounds torque. DO NOT EXCEED 60 FOOT POUNDS TORQUE.

  16. Ground Cable Shield and Waterproof Jacket

    Insert one end of a wire (with ampacity at least equivalent to No. 14 AWG Copper) through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; ground it according to the instructions supplied with any grounding device, or by an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  17. Install Loadbreak Interface (Optional)

    Clean and lubricate the entire loadbreak interface and either a DR(G), ESA, GLR, or LR of the appropriate voltage class with the supplied lubricant or an ELASTIMOLD® approved lubricant. Install the DR(G), ESA, GLR, or LR to the tap plug interface following the instructions supplied with those specific products.

  18. Verify Seating Indication

    Confirm the complete assembly of an insulated cap or elbow by ensuring no portion of the colored interface sleeve is visible when viewed from the side.

  19. Perform Voltage Test (656CETP only)

    WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the specific meter used. Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. Test with a suitable sensing device designed for capacitive test points to determine if the cable is energized. Contamination, moisture, or incorrect equipment can provide a false 'no voltage' indication; treat the elbow as energized until confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.