ABB - Installation Products 655CETPF0260DRG - 600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.

ABB Installation Products 655CETPF0260DRG 600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and…

UPC: 075114177092


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 655CETPF0260DRG is a 15kV, 600 Amp Combo T Elbow Reducing Tap Plug Kit engineered for medium-voltage electrical systems requiring secure, insulated tap connections. This kit includes a stud, cable adapter, lug, and insulated cap, providing a complete solution for 200 Amp tap-offs from a 600 Amp main circuit. Designed for compatibility with compressed stranded 3/0 AWG, compacted solid 4/0 AWG, or 95 mm² compact conductors, the plug accommodates cable insulation diameters from 0.640" to 0.820". The aluminum construction ensures durability and optimal conductivity in demanding industrial environments. Key features include a simplified connection system that reduces stack height by 2.67" and minimizes cross-threading risks during installation. The internal hex broach ensures proper torque application, while the IEEE 386 color-coded PBT interface improves visibility and seating verification. The hollow bore design allows visual confirmation of lug positioning before final assembly. Installation requires standard tools, with the 600ATM assembly tool recommended for optimal performance. This tap plug meets ANSI/IEEE Standard 386 requirements, including 8.3kV phase-to-ground and 14.4kV phase-to-phase operating voltages, with a 95kV BIL impulse withstand rating. It supports 200 Amp continuous and loadbreak operations, with a 10kA symmetrical momentary rating. The kit is designed for deadbreak applications, ensuring safe operation when connecting to energized equipment. For 900 Amp applications, refer to the 675ETPSP series. Applications include medium-voltage distribution systems, industrial power networks, and utility substations where reliable tap connections are critical. The absence of a test point simplifies installation and reduces potential failure points in configurations where testing is not required.
  • 600 Amp main / 200 Amp tap connection for medium-voltage systems
  • Aluminum construction with 0.640"–0.820" cable insulation compatibility
  • Supports 3/0 AWG compressed stranded, 4/0 AWG compacted solid, or 95 mm² compact conductors
  • IEEE 386 color-coded PBT interface for improved visibility and seating verification
  • Internal hex broach ensures proper torque; installs with standard 600ATM tool

Specifications

Amperage Rating
600 A
Application
600 Amps, 15kV Connector
Color
Black
Conductor Range
3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG
Connection Type
Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit
Current Rating
600 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Material
Aluminum
Size
Cable Insulation Diameter 0.640 inch to 0.820 inch
Special Features
Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
ComboT Elbow
Voltage Rating
15 kV
Width
13.31 in
Width
338.074 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. 200ECS Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.

656ETP-H0260-DRG-S

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. 200ECS Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Shrink-Fit Jacket Seal Kit.

655CETPL0330DRGS

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Shrink-Fit Jacket Seal Kit.
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

655CETP-K0330-DRG

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit, No Test Point, Aluminum, Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
15kv, 600 Amp, Combo T Connector with Bus, Stud, Cable Adapter and Aluminum Lug, No Test Point, includes Insulated Cap, Cable Insulation Diameter .760-.950 inches, Conductor Size 2/0 Compressed/Stranded or 3/0 Compact/Solid.

655CETP-G0250-DRG

15kv, 600 Amp, Combo T Connector with Bus, Stud, Cable Adapter and Aluminum Lug, No Test Point, includes Insulated Cap, Cable Insulation Diameter .760-.950 inches, Conductor Size 2/0 Compressed/Stranded or 3/0 Compact/Solid.
15kv 600 Amp Dead Break Combo T Elbow with 200 Amp Reducing Tap Plug, Stud, Cable adapter and Lug Kit without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size Compressed Stranded 350 kcmil or Solid Compact 400 kcmil. Includes Insulated cap

655CETP-K0300-DRG

15kv 600 Amp Dead Break Combo T Elbow with 200 Amp Reducing Tap Plug, Stud, Cable adapter and Lug Kit without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Universal Aluminum Compression Lug. Conductor Size Compressed Stranded 350 kcmil or Solid Compact 400 kcmil. Includes Insulated cap
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Aluminum Lug, No Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed Stranded 350 kcmil or Compacted Solid 400 kcmil. With Insulated Cap

655CETP-J5300-DRG

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Aluminum Lug, No Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed Stranded 350 kcmil or Compacted Solid 400 kcmil. With Insulated Cap
15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Insulated Cap and Shrink-Fit Jacket Seal Kit

K656CETP-P0410-DRGS

15/25kV, 600 Amp Base Aluminum, includes test point, Combo T Elbow Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. With Insulated Cap and Shrink-Fit Jacket Seal Kit

Frequently Asked Questions

What stud size is used for assembly?

The 15 kV CETP and 15/25 kV CCP connectors utilize a standard 5/8 in –11 stud for assembly into the equipment bushing.

What are the continuous current ratings for CCP/CBW?

CCP and CBW connectors have continuous current ratings of 600 A and 900 A.

What are the voltage ratings for CCP/CBW connectors?

CCP and CBW connectors have a voltage class of 15/25/28 kV. The maximum phase-to-ground operating voltage is 16.2 kV.

What are the continuous current ratings for CETP?

CETP connectors have continuous current ratings of 600 A for deadbreak and 200 A for loadbreak connections. 900 A deadbreak options are also available.

What are the voltage ratings for CETP connectors?

CETP connectors are available in 15 kV and 25 kV classes. Maximum phase-to-ground operating voltage is 8.3 kV for 15 kV and 15.2 kV for 25 kV.

What is the stack height reduction?

Each combination elbow/connecting plug reduces the stack height by 2.67 inches. This allows for installation in smaller cabinets and tighter spaces.

What safety precaution is required before installation?

The system needs to be de-energized before initiating any installation of the ComboT integral separable connectors.

What is the stack height reduction?

Each combination elbow/connecting plug reduces the stack height by 2.67 inches. This allows for installation in smaller cabinets and tighter spaces.

What safety precaution is required before installation?

The system needs to be de-energized before initiating any installation of the ComboT integral separable connectors.

What stud size is used for assembly?

The 15 kV CETP and 15/25 kV CCP connectors utilize a standard 5/8 in –11 stud for assembly into the equipment bushing.

How to Install 655/656/675/676CETP Deadbreak Elbow Connectors

This guide provides detailed instructions for the safe and proper installation of 655/656/675/676CETP Deadbreak Elbow Connectors, including cable preparation, lug crimping, and final assembly for high voltage apparatus. Ensure all safety precautions are followed.

Estimated time: 1h 30m

Tools needed:

Cable cutting tool, Wire strippers, Crimping tool, Wire brush (for aluminum conductor), 600AT assembly tool (for products dated Sep 30, 2013 or earlier), 600ATM assembly tool (for products dated Oct 1, 2013 or later), Hotstick, Suitable sensing device (for voltage test)

Supplies needed:

655/656/675/676CETP Elbow connector, Cable adapter, Compression lug, Lubricant (supplied), Vinyl plastic tape, Tape retainer (if applicable), Tape marker, Ground wire (at least No. 14 AWG Copper), Suitable connector for ground, HV insulated cap(s) or connector(s) (if replacing shipping covers), Silicone grease (for test point cap)

  1. Perform Safety and Pre-installation Checks

    WARNING: De-energize all apparatus before installation or removal. Do not touch or move energized products. This product must be installed only by competent personnel trained in high voltage electrical equipment safety. Inspect all parts for damage, proper rating, and compatibility with mating parts. Check package contents for completeness. Have all required tools at hand and maintain cleanliness throughout the procedure. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before energizing or submerging.

  2. Prepare the Cable End

    Position the cable with enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for 24 inches (610mm). Remove the outer jacket, shield wires, flat metallic tape shield, fabric tape shield, longitudinally corrugated shield, UNISHIELD® cable, lead sheath cable, or semi-con shield according to the specific cable type and dimensions provided in the documentation. Ensure not to cut or nick the cable insulation.

  3. Install Cable Adapter and Prepare Conductor

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker. Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The exposed conductor length should be 4-3/8 to 4-11/16 inches (111mm-119mm); otherwise, redo the assembly.

  4. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping; it should be less than 6-1/2 inches (165mm). Crimp the compression lug following the instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be 6-1/2 to 7-1/4 inches (165mm-184mm); otherwise, redo the assembly.

  5. Install the Elbow Connector

    Lubricate the cable adapter and the inside of the elbow cable entrance with the supplied lubricant. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  6. Connect to Mating Product

    DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from the elbow and the mating part. Install the stud into the apparatus by hand until fully seated. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Push the elbow onto the mating part. For products dated September 30, 2013 or earlier, use the 600AT assembly tool to torque the contact assembly until the torque limiter ratchets (19 to 25 foot/pounds). For products dated October 1, 2013 or later, use the 600ATM assembly tool and tighten to 50-60 foot/pounds torque, but do not exceed 60 foot-pounds.

  7. Ground the Cable Shield

    Insert one end of a wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, ensuring not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded according to the instructions supplied with any grounding device used, or through an alternate method if no grounding device is present. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  8. Install Loadbreak Interface (Optional)

    Clean and lubricate the entire loadbreak interface and either a DR(G), ESA, GLR, or LR of the appropriate voltage class with the supplied lubricant or ELASTIMOLD® approved lubricant. Install the DR(G), ESA, GLR, or LR to the tap plug interface following the instructions supplied with those specific products.

  9. Verify Seating and Test Voltage

    Verify complete assembly by ensuring no portion of the colored interface sleeve is visible when viewed from the side. If the ELASTIMOLD® deadbreak elbow connector has an integral capacitance test point, remove the test point cap with a hotstick (peel off at an angle). WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Use a suitable sensing device made for capacitive test points and follow its manufacturer’s directions. Do not use conventional voltage measuring equipment. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means to prevent serious injury. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.