ABB Installation Products 35PCJ1P 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786636808
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV voltage rating for medium-voltage power systems
- Single-piece housing for simplified installation
- Accommodates cable insulation diameters from 1.725" to 1.935"
- Style 1 joint design
- Manufactured by ABB - Installation Products
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Size | 15-3/4 inch long |
Size | 1.725 inch to 1.935 inch |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.2500 L |
Package Weight (Metric) | 1.4740 kg |

35PCJ1-H
35kV, PCJ - Power Cable Joint, with Single Piece Housing, Cable Insulation Diameter .850 - 1.050 inches, Housing Only
35PCJ1L1280
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 250.
35PCJ1J
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch.
25PCJ1G1220
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
25PCJ1K1270
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
25PCJ1L2290
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 350.
15PCJ2N1410-M1380
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
15PCJ1H2280
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 250.Frequently Asked Questions
What voltage classes are available for PCJ power cable joints?
Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
What is the short-time current rating of PCJ power cable joints?
The short-time current rating is equal to that of the cable rating, up to 35 kA.
Can copper connectors be used with aluminum conductors?
No, copper compression connectors are suitable for copper-to-copper connections only and should not be used on aluminum conductors.
What is the continuous current rating of PCJ power cable joints?
The continuous current rating of PCJ power cable joints is equal to that of the cable rating.
What pull force can the pin-and-socket interlock withstand?
The pin-and-socket interlock is designed to withstand a pull force of up to 500 lb.
What is the phase-to-ground voltage for a 35 kV class joint?
For a 35 kV class joint, the phase-to-ground voltage is 20.2 kV.
What is the BIL impulse withstand for a 35 kV class joint?
The BIL impulse withstand for a 35 kV class joint is 300 kV (1.2 x 50 μsec. wave).
What conductors are aluminum compression connectors suitable for?
Aluminum compression connectors are suitable for splicing aluminum conductor to aluminum conductor or aluminum conductor to copper conductor.
Do PCJ power cable joints provide a ground shield?
Yes, a molded conductive shield provides a virtually unbreakable ground shield for true dead-front construction. A grounding eye connects a ground wire.
Is taping required for cable entrance insulation shielding?
No, the cable entrance engages the insulation shielding of the cable, eliminating the need for taping.
How to Install the 15/25/35PCJ1,NPQ Straight Joint
This guide provides step-by-step instructions for installing the 15/25/35PCJ1,NPQ series straight joint, a permanent, fully shielded, and submersible joint for wire shielded cables. Ensure all apparatus are de-energized before beginning installation to prevent serious injury or fatality.
Estimated time: 2h
Tools needed:
Cable cutting tool, Cable jacket removal tool, Cable insulation removal tool, Wire-brush, Crimping tool, T&B WT3D tool (for 35kV only)
Supplies needed:
Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Connector (User Supplied), DELTECt Cable ties (TYD5135, for 35kV only), #14 AWG copper wire or equivalent (if shield wires are smaller than #14 AWG)
- Perform Safety Checks and Initial Preparations
DANGER: Ensure all apparatus are de-energized before installation. Do not touch or move energized products. Inspect all parts for damage, proper rating, and compatibility with mating parts. Check package contents for completeness. Read the entire instructions and have all required tools ready, maintaining cleanliness throughout the procedure.
- Prepare Cables for Joint Centerline
Overlap both cables and cut them to 12 inches (305mm) from the intended center line of the joint. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Finally, cut both cables precisely at the center line of the joint.
- Prepare Cable 1 and Store Housing
Taper the edge of Cable 1's insulation shield from at least 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Carefully slide the joint housing onto Cable 1, pushing it up to the shield wires for temporary storage.
- Prepare Cables for Splice Installation
Carefully remove the cable insulation from both Cable 1 and Cable 2 to the specified 'Y' dimension (e.g., 2 1/2 inches for 500-750 MCM, 2 3/8 inches for 1000 MCM). Then, carefully remove the insulation shield from both cables to the specified 'X' dimension (e.g., 6 1/4 inches for 500-750 MCM, 6 3/8 inches for 1000 MCM). DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR during this process.
- Install and Crimp the Splice
If conductors are aluminum, wire-brush them immediately before insertion into the splice. Insert the conductors into the splice and check the dimension against the 'Max Check Before' table (e.g., 6 inches for 500-750 MCM, 6 7/8 inches for 1000 MCM); redo if it exceeds. Crimp the splice according to its provided recommendations. Wipe off any excess inhibitor. Check the distance between cable insulations against the 'Max Check After' table (e.g., 6 1/4 inches for 500-750 MCM, 6 1/2 inches for 1000 MCM); redo if it exceeds. Remove any sharp protrusions or burrs from crimping and clean metal chips from the splice and joint area. Clean and lubricate the cables where indicated, building up lubricant at the edge of the insulation shield.
- Complete Joint Assembly and Grounding
Slide the joint housing into its final position, ensuring proper placement by equalizing the deformation of the joint ends. For 35kV ONLY: Install two DELTECt Cable ties (TYD5135) 1/4 inch apart on each cable entrance, with offset locking heads, using the T&B WT3D tool. Remove and discard the yellow pin from the joint grounding eye. Retrain and secure shield wires to the joint ends. Insert one shield wire from each cable (if #14 AWG or larger) through the joint grounding eye; use separate #14 AWG copper wire if smaller. Connect all joint grounding wires and remaining shield wires with an appropriate connector. Reconstruct the cable jacket (if applicable) over cables and joint housing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.