Authorized ABB Distributor (Installation Products)
ABB - Installation Products 25PCJ1G1220 - 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

ABB Installation Products 25PCJ1G1220 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786636921


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 15

Multiplier: 15

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 25PCJ1G1220 25kV Power Cable Joint Style 1 is a fully shielded, fully submersible straight splice designed for permanent, reliable termination of medium-voltage power cables. Engineered to meet IEEE Standard 404 for 25kV applications, this joint accommodates aluminum conductors with stranded #2 AWG or solid #1 AWG sizes, ensuring compatibility with a wide range of cable constructions. The single-piece molded rubber housing provides a robust, weather-resistant seal with a pin-and-socket interlock capable of withstanding up to 500 lbs of pull force, making it ideal for direct burial or vault installations. The housing is rated for cable insulation diameters from 0.760 inches to 0.950 inches, offering a precise fit for specified cable types. Key features include a molded conductive shield for true deadfront construction, eliminating the need for additional taping, and a grounding eye for secure connection to ground potential. The joint meets a 150kV BIL impulse withstand rating, 52kV AC withstand, and 22kV AC corona extinction at 3pC sensitivity, ensuring long-term operational stability under demanding conditions. With a continuous current rating equal to the cable rating and a short-time current rating up to 35kA, this joint is optimized for medium-voltage distribution systems where reliability and safety are critical. The ABB Installation Products series 25PCJ1G1220 is a trusted solution for new installations or repairs in industrial, utility, and infrastructure projects requiring dependable cable splicing.
  • 25kV rated per IEEE Standard 404 with 150kV BIL impulse withstand
  • Accommodates aluminum conductors: stranded #2 AWG or solid #1 AWG
  • Single-piece molded rubber housing for weather-resistant, submersible installation
  • Pin-and-socket interlock withstands up to 500 lbs of pull force
  • Molded conductive shield eliminates need for additional taping

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
#2 STR AWG , #1 SOL AWG
Connection
Compression
Connection Type
Cable Joint (Splicing)
Insulation
Yes
Material
EPDM Rubber
Material
Aluminum Conductor, Single Piece Housing (Polyurethane or similar)
Mounting Type
Direct Burial/Inline Joint
Number Of Conductors
2
Series
25PCJ1G
Size
14-3/8 inch long
Size
0.760-0.950 inch (Insulation Diameter)
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.7400 L
Package Weight (Metric)
0.7890 kg
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded #2/Solid #1.

25PCJ1G2220

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded #2/Solid #1.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

25PCJ1K1270

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 350.

25PCJ1L2290

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 350.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.

15PCJ2N1410-M1380

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 250.

15PCJ1H2280

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ1J1270

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.

35PCJ1K1260

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

15PCJ1G1250

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

Frequently Asked Questions

What is the maximum voltage rating for this cable joint?

The ABB 25kV Power Cable Joint Style 1 is rated for operation at up to 25 kV.

What conductor sizes does this joint support?

This joint is designed for aluminum conductors, supporting AWG #2 stranded or AWG #1 solid.

What is the acceptable range for cable insulation diameter?

The joint is suitable for cable insulation diameters ranging from 0.760 inches to 0.950 inches.

What type of conductor material is this joint designed for?

This joint is specifically designed for aluminum conductors.

What is the series designation for this ABB cable joint?

This cable joint belongs to the ABB 25PCJ1G series.

How to Install the 15/25/35PCJ1 Series Straight Cable Joint

This guide provides detailed instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ1 series straight joint for aluminum or copper conductors in wire shielded cables. Ensure all safety precautions are followed.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Wire brush (for aluminum conductors), Crimping tool, Measuring tape, T&B WT3D tool (recommended for 35kV only)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Appropriate connector (for grounding), #14 AWG copper wire (or equivalent, if needed), DELTECt Cable ties (for 35kV only)

  1. Prepare Cables for Jointing

    Overlap both cables and cut them to 12 inches (305mm) from the joint centerline. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Finally, cut both cables at the joint centerline.

  2. Prepare Cable 1 and Store Housing

    Taper the edge of Cable 1 insulation at least 1/2 inch to no greater than 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Carefully slide the housing onto Cable 1, positioning it up to the shield wires.

  3. Prepare Cables for Splice Installation

    Carefully remove the cable insulation and then the insulation shield from both cables according to the specified dimensions (e.g., 'Y' and 'X' in the document's table). Exercise extreme caution: DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR, as this can lead to product failure and serious injury.

  4. Install the Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Check the dimension against the 'Max Check Before' table provided in the documentation; if it exceeds, redo the assembly. Crimp the splice following the manufacturer's recommendations. Wipe off any excess inhibitor. Verify the distance between cable insulations against the 'Max Check After' table; redo if it exceeds. Remove any sharp protrusions or burrs generated during crimping. Clean cables where indicated and lubricate in the direction of arrows to create a lubricant build-up at the insulation shield edge.

  5. Complete Joint Assembly

    Slide the housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV ONLY: Install two DELTECt Cable ties on each end of the cable entrance, approximately 1/4 inch from the splice edge and 1/4 inch from the first tie with offset locking heads. Use a T&B WT3D tool to tighten and trim ties. Remove and discard the yellow pin from the joint grounding eye. Retrain shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, repeating for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket (where applicable) over both cables and the joint housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.