Authorized ABB Distributor (Installation Products)
ABB - Installation Products 35PCJ1L1280 - 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 250.

ABB Installation Products 35PCJ1L1280 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786637812


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products 35kV Power Cable Joint (SKU: 35PCJ1L1280) is a single-piece, fully shielded, fully submersible straight splice designed for 35kV power cable systems with aluminum conductors. This joint accommodates cable insulation diameters from 1.180 inch to 1.465 inch and is rated for 250 AWG stranded aluminum conductors, meeting IEEE Standard 404 for 35kV voltage class. The molded conductive shield provides a virtually indestructible ground shield for true deadfront construction, ensuring long-term dielectric integrity and mechanical stability under typical operating conditions. Key specifications include a 200kV BIL impulse withstand rating (1.2 x 50 microsecond wave), 69kV AC withstand, and 30kV AC corona extinction at 3pC sensitivity. The joint supports continuous current ratings equal to the cable rating and short-time current ratings up to 35kA. The pin and socket interlock design withstands pulls of up to 500 lbs, making it suitable for direct burial or vault installations. The grounding eye allows convenient connection of a ground wire to the molded conductive shield, placing it at ground potential. The single-piece housing simplifies installation by eliminating multi-part assembly steps, reducing labor time while maintaining consistent performance. The cable entrance engages the insulation shielding of the cable, eliminating the need for taping. This joint is designed for use on UD cable with concentric neutral and extruded insulation shielding, but operates equally well on fabric tape shielded or lead-jacketed cables when used with the proper Elastimold® cable shield adapter or grounding device. Ideal for medium-voltage distribution networks, this joint supports efficient installation workflows in substations, switchgear, and industrial power distribution systems.
  • Single-piece housing for simplified installation and reduced labor time
  • Fully shielded, fully submersible design for direct burial or vault installations
  • Rated for 35kV voltage class per IEEE Standard 404
  • Accommodates 250 AWG stranded aluminum conductors and 1.180-1.465" insulation diameters
  • Pin and socket interlock withstands pulls up to 500 lbs

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
250 kcmil
Connection
Compression
Connection Type
Cable Joint
Insulation
Yes
Material
EPDM Rubber
Material
Aluminum Conductor, Single-Piece Housing
Number Of Conductors
2
Series
Style 1
Size
14-3/8 inch long
Size
1.180-1.465 inch insulation diameter, 250 AWG stranded conductor
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.7500 L
Package Weight (Metric)
0.7940 kg
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 250

25PCJ1H1280

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 250
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch.

35PCJ1J

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

25PCJ1G1220

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

25PCJ1K1270

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 350.

25PCJ1L2290

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 350.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.

15PCJ2N1410-M1380

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 250.

15PCJ1H2280

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ1J1270

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

Frequently Asked Questions

Can copper connectors be used with aluminum conductors?

No, copper compression connectors are suitable for splicing copper conductors to copper conductors only and should not be used on aluminum conductors.

What voltage classes are available for PCJ power cable joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What conductor types and sizes are compatible with PCJ joints?

PCJ power cable joints are compatible with copper or aluminum conductors. They can accommodate a wide range of conductor sizes up to 1250 kcmil.

Where can Elastimold PCJ power cable joints be installed?

These joints can be installed in direct-burial, underground vault, and even overhead applications. They provide a permanent, fully shielded, and fully submersible splice.

What are the two styles of PCJ power cable joints?

PCJ power cable joints come in Style 1 with a single-piece housing for straight splicing, and Style 2 with universal housing and separate cable adapters for transition splicing.

What are the main applications of PCJ power cable joints?

PCJ power cable joints are used for straight splicing of two similar cables or transition splicing of different cable sizes. They can join new cable runs or repair broken cables.

What is the pull force rating for the pin-and-socket interlock?

The pin-and-socket interlock in the PCJ power cable joints is designed to withstand a pull force of up to 500 lb.

What industry standards do PCJ power cable joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

What is the continuous current rating of PCJ power cable joints?

The continuous current rating of PCJ power cable joints is equal to that of the cable rating.

What is the short-time current rating for PCJ power cable joints?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

How to Install the 35PCJ1 Straight Joint

This guide provides detailed instructions for the permanent installation of the 35PCJ1 straight joint, designed for fully shielded, fully submersible connections between aluminum and/or copper conductor, wire shielded cables.

Estimated time: 3h

Tools needed:

Cable cutters, Cable stripping tool, Knife, Wire brush, Crimping tool, T&B WT3D tool (for 35kV cable ties)

Supplies needed:

User-supplied connector (for conductors), Deltect Cable ties TYD5135 (for 35kV ONLY), #14 AWG copper wire or equivalent (if shield wires are smaller than #14 AWG)

  1. De-energize and Prepare Cables for Joint Centerline

    DANGER: De-energize all apparatus during installation or removal. Ensure the work area is free of energized products. Overlap both cables and cut them to 12 inches (305mm) from the joint centerline. Remove the cable jacket from Cable 1 to 37 inches (940mm) and from Cable 2 to 21 inches (530mm). Fold back the shield wires on both cables. Cut both cables precisely at the joint centerline.

  2. Prepare Cable 1 and Store Joint Housing

    Taper the edge of Cable 1's insulation shield from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the joint housing onto Cable 1, positioning it up to the shield wires for temporary storage.

  3. Prepare Cables for Splice Installation

    Carefully remove the cable insulation from both Cable 1 and Cable 2. For 500-750 MCM conductors, remove 2 1/2 inches (64mm); for 1000 MCM conductors, remove 2 3/8 inches (68mm). Then, carefully remove the insulation shield from both cables. For 500-750 MCM conductors, remove 6 1/4 inches (159mm); for 1000 MCM conductors, remove 6 3/8 inches (162mm). WARNING: Do not cut or nick the cable insulation or conductor during this process.

  4. Install and Crimp the Conductor Splice

    If using aluminum conductors, wire-brush them thoroughly and immediately insert them into the splice. Verify the conductor insertion dimension against the 'Max Check Before' table (6 inches (152mm) for 500-750 MCM; 6 7/8 inches (156mm) for 1000 MCM). If it exceeds, re-do the assembly. Crimp the splice according to the manufacturer's recommendations provided with the splice. Wipe off any excess inhibitor from the splice. Check the distance between the cable insulations against the 'Max Check After' table (6 1/4 inches (159mm) for 500-750 MCM; 6 1/2 inches (165mm) for 1000 MCM). If it exceeds, re-do the assembly. Remove any sharp protrusions or burrs generated during crimping. Ensure all metal chips and filings are removed from the splice and joint assembly area. Clean the cables as indicated in the diagram. Lubricate the cables in the direction of the arrows to create a build-up or ramp of lubricant at the edge of the insulation shield.

  5. Complete Joint Assembly and Grounding

    Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV ONLY: Install two DELTECt Cable ties (TYD5135) on each end of the cable entrance. Position the outer ties approximately 1/4 inch (6mm) from the splice edge, and the second ties approximately 1/4 inch (6mm) from the first, with an offset of their locking heads. Use the T&B WT3D tool to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint as shown in the diagram. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye. Repeat this for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector. Reconstruct the cable jacket (where applicable) over both cables and the joint housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.