ABB Installation Products 35PCJ1N1360 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786642076
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Voltage rating: 35 kV for medium-voltage distribution
- Conductor: 750 AWG solid aluminum
- Insulation diameter range: 1.515" to 1.780"
- Single-piece housing for simplified installation
- Compatible with ABB Series 35PCJ1 joints
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 750 kcmil |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Size | 15-3/4 inch long |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.6500 L |
Package Weight (Metric) | 1.6560 kg |

35PCJ1N1380-S
35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Jacket Seal included.
35PCJ1N1410
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.
25PCJ1N2410
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000.
25PCJ2-DP0597069
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. DP0597059.
35PCJ1M1310S
35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240. Cold Shrinkable Jacket Seal included.
35PCJ1M1380
35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 700/750, Solid 900.
35PCJ1N1360S
35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400. Cold Shrinkable Jacket Seal included.
35PCJ1M1400
35 kV, Power Cable Joint, Style 1 - 14-3/8 X 2-25/32 inches, Cable Insulation Diameter - 1.370-1.630 inches, Aluminum Connector, Conductor Size - 1000 kcmil.Frequently Asked Questions
What are the available voltage classes for PCJ joints?
Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
What is the BIL impulse withstand for a 35 kV PCJ joint?
For a 35 kV class PCJ joint, the BIL impulse withstand (1.2 x 50 μsec. wave) is 300 kV.
What type of connector is included for aluminum conductors?
Kits with catalog numbers ending in 'W1X' include an aluminum compression connector suitable for splicing aluminum to aluminum or aluminum to copper conductors.
How do I select the correct PCJ joint for conductor size?
Use Table X7 for all PCJ styles to match the conductor size in AWG or kcmil to the corresponding symbol for X.
How do I select the correct PCJ joint for cable insulation diameter?
Use Table W8 for 15 PCJ, Table W9 for 25 PCJ, and Table W10 for 35 PCJ to match the cable insulation diameter in inches to the corresponding symbol for W.
What is the short-time current rating of PCJ joints?
The short-time current rating is equal to that of the cable rating, up to 35 kA.
What is the continuous current rating of PCJ joints?
The continuous current rating of PCJ power cable joints is equal to that of the cable rating.
What standards do PCJ joints meet?
The shield design meets IEEE 592 standard, and connectors meet ANSI 119.4 Class A and Class 3 ratings. Electrical ratings meet IEEE 404, latest revision.
What safety features do PCJ power cable joints have?
They feature a molded conductive shield for true dead-front construction and a grounding eye to connect a ground wire, placing the shield at ground potential.
Do PCJ joints require taping for cable entrance?
No, the cable entrance engages the insulation shielding of the cable, eliminating the need for taping.
How to Install the 35PCJ1 Series Straight Joint
This guide provides detailed instructions for the permanent, fully shielded, and submersible installation of the 35PCJ1 series straight joint for aluminum to aluminum and/or aluminum to copper conductor, wire shielded cables.
Estimated time: 2h
Tools needed:
Wire-brush, Crimping tool, T&B WT3D tool (for 35kV only), Measuring tape/ruler, Cable jacket removal tool, Insulation removal tool, Knife/tapering tool
Supplies needed:
Joint Housing (included), Splice (Conductor Contact) (included), Lubricant (DO NOT SUBSTITUTE) (included), User-supplied connector (for conductor), Appropriate connector (for grounding wires/shield wires), DELTECt Cable ties TYD5135 (for 35kV only), #14 AWG copper wire or equivalent (if shield wires are smaller than #14 AWG)
- Ensure Safety and Inspect Components
DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. This product must be installed only by competent personnel trained in high voltage safety practices. Inspect all package contents for completeness and damage. Verify all components for proper fit with the cable and/or mating products.
- Prepare Cables for Joint Centerline
Overlap both cables and cut them to 12 inches (305mm) from the intended centerline of the joint. Remove the cable jacket from Cable 1 to 37 inches (940mm) and from Cable 2 to 21 inches (530mm). Fold back the shield wires on both cables. Finally, cut both cables precisely at the joint centerline.
- Prepare Cable 1 and Store Joint Housing
Taper the edge of Cable 1's insulation shield from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Carefully slide the joint housing onto Cable 1, pushing it back until it rests against the folded shield wires.
- Prepare Cables for Splice Installation
Carefully remove the cable insulation from both Cable 1 and Cable 2 according to the dimensions 'X' and 'Y' provided in the documentation (e.g., 2 1/2" for 500-750 MCM, 2 3/8" for 1000 MCM for 'X'; 6 1/4" for 500-750 MCM, 6 3/8" for 1000 MCM for 'Y'). Subsequently, remove the insulation shield from both cables. Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor during this process.
- Install and Crimp the Conductor Splice
If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Check the dimension against the 'Max Check Before' table (e.g., 6" for 500-750 MCM, 6 7/8" for 1000 MCM). Crimp the splice following the recommendations provided with the splice. Wipe off any excess inhibitor. Check the distance between cable insulations against the 'Max Check After' table (e.g., 6 1/4" for 500-750 MCM, 6 1/2" for 1000 MCM). Remove any sharp protrusions or burrs generated during crimping and ensure all metal chips/filings are cleared from the splice and joint assembly area.
- Lubricate Cables and Position Joint Housing
Clean the cables where indicated in the diagram. Lubricate the cables in the direction of the arrows, ensuring a build-up or ramp of lubricant is created at the edge of the insulation shield. Slide the joint housing into its final position over the splice. Ensure proper positioning by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield.
- Complete Grounding and Jacket Reconstruction
For 35kV installations ONLY: Install two DELTECt Cable ties on each end of the cable entrance. Position the outer ties approximately 1/4 inch (6mm) from the edge of the splice, then install the second ties approximately 1/4 inch (6mm) from the first, with an offset of their locking heads. Use the T&B WT3D tool (not included) to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint as shown in the diagram. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and any remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.