Overview
- 25 kV operating voltage rating for medium-voltage applications.
- Style 1 power cable joint with aluminum connector.
- Accommodates cable insulation diameters from 1.370 to 1.630 inches.
- Designed for 1000 kcmil conductor size.
- Physical dimensions: 14-3/8" length x 2-25/32" width.
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 1000 kcmil |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Size | 14-3/8 inch long |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

25PCJ1N1410-0MA
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Metallic Tape Shield Adapter. Replacement part is 600ECS-G3.
25PCJ1M1380
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
25PCJ1M2360-ELA
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750. Elastimold
25PCJ1N1380
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
25PCJ1M2330
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 500.
25PCJ1M2360
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750.
35PCJ1M1300
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.
35PCJ1M1280-1270
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 250. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.Frequently Asked Questions
What is the maximum operating voltage for this ABB cable joint?
The ABB 25PCJ1M1400 power cable joint is rated for 25 kV, making it suitable for medium-voltage applications.
What cable insulation diameter range does the 25PCJ1M1400 support?
This ABB cable joint is designed to accommodate cable insulation diameters between 1.370 and 1.630 inches.
What conductor size is compatible with the 25PCJ1M1400?
The 25PCJ1M1400 power cable joint is designed for a conductor size of 1000 kcmil.
What material is the connector made of in the 25PCJ1M1400?
The ABB 25PCJ1M1400 features an aluminum connector for reliable conductivity.
What are the physical dimensions of the ABB 25PCJ1M1400 cable joint?
The ABB 25PCJ1M1400 has a length of 14-3/8 inches and a width of 2-25/32 inches.
How to Install the 15/25/35PCJ1 Series Straight Joint
This guide provides step-by-step instructions for the installation of the 15/25/35PCJ1 series straight joint, ensuring proper preparation, splicing, and assembly for wire shielded cables.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Wire brush, Crimping tool, T&B WT3D tool (for 35kV only)
Supplies needed:
Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Conductor connector (user supplied), Grounding wire (#14 AWG copper or equivalent), DELTECt Cable ties (TYD5135, for 35kV only), Electrical connectors
- Prepare for Installation and Ensure Safety
Before starting, ensure all apparatus is de-energized. This product must be installed only by competent personnel trained in high voltage safety practices. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Read the entire instructions and gather all required tools, maintaining cleanliness throughout the procedure.
- Prepare Cable Overlap and Jacket
Overlap both cables and cut them to 12 inches (305mm) from the joint centerline, ensuring sufficient shield wire length. If applicable, remove the cable jacket from Cable 1 to 37 inches (940mm) and from Cable 2 to 21 inches (530mm). Fold back the shield wires and then cut both cables at the joint centerline.
- Taper Cable 1 and Position Housing
Taper the edge of Cable 1 insulation shield from 1/2 inch (13mm) to 1-1/2 inches (38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Carefully slide the housing onto Cable 1, positioning it up to the shield wires.
- Remove Cable Insulation and Shield
Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2, ensuring not to cut or nick the cable insulation or conductor. Refer to the provided table for specific 'X' and 'Y' dimensions based on your conductor size (e.g., for 500-750 MCM, X=2 1/2 inches (64mm), Y=6 1/4 inches (159mm); for 1000 MCM, X=2 3/8 inches (68mm), Y=6 3/8 inches (162mm)).
- Install and Crimp the Conductor Splice
If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Verify the dimension against the 'Max Check Before' table; if it exceeds the maximum, redo the assembly. Crimp the splice according to its specific recommendations. Wipe off any excess inhibitor. Check the distance between cable insulations against the 'Max Check After' table; if it exceeds the maximum, redo the assembly. Remove any sharp protrusions or burrs from the crimped splice and the joint assembly area. Clean the cables as indicated and apply lubricant in the direction of the arrows to create a build-up at the edge of the insulation shield.
- Finalize Joint Assembly and Grounding
Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV installations only, install two DELTECt Cable ties on each end of the cable entrance, approximately 1/4 inch (6mm) from the splice edge and then 1/4 inch (6mm) from the first tie with offset locking heads; use a T&B WT3D tool to tighten and trim. Remove and discard the yellow pin from the joint grounding eye (35kV only). Retrain and secure the shield wires to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket over both cables and the joint housing where applicable.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.