Authorized ABB Distributor (Installation Products)
ABB - Installation Products 35PCJ1M1400 - 35 kV, Power Cable Joint, Style 1 - 14-3/8 X 2-25/32 inches, Cable Insulation Diameter - 1.370-1.630 inches, Aluminum Connector, Conductor Size - 1000 kcmil.

ABB Installation Products 35PCJ1M1400 35 kV, Power Cable Joint, Style 1 - 14-3/8 X 2-25/32 inches, Cable Insulation Diameter…

UPC: 075114311953


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 35PCJ1M1400 is a 35 kV power cable joint designed for permanent, fully shielded, and fully submersible straight splices in medium-voltage power cable systems. Rated per IEEE Standard 404, this joint accommodates cable insulation diameters from 1.370 to 1.630 inches and supports 1000 kcmil aluminum conductors. The joint features a molded conductive shield for a virtually indestructible ground shield, enabling true deadfront construction and eliminating the need for taping during installation. Key electrical ratings include a 200kV BIL impulse withstand, 69kV AC withstand, 125kV DC withstand during manufacturing, and 100kV DC withstand during installation. The corona extinction level is 30kV AC at 3pC sensitivity, with a continuous current rating equal to the connected cable. The short-time current rating matches the cable rating up to 35kA. The shield design complies with IEEE Standard 592. The joint’s housing is fully shielded and submersible, with a pin-and-socket interlock capable of withstanding pulls up to 500 lbs. It is suitable for direct burial or vault installations and works with UD cables featuring concentric neutral and extruded insulation shielding. For fabric tape shielded or lead-jacketed cables, use the appropriate Elastimold cable shield adapter or grounding device. The grounding eye provides a convenient point for connecting a ground wire to the molded conductive shield, ensuring the shield remains at ground potential. The ABB 35PCJ1M1400 is part of ABB’s Installation Products catalog, providing essential components for reliable electrical infrastructure. Proper installation is critical to maintaining system integrity and safety. The product is identified by SKU 35PCJ1M1400 and UNSPSC code 39121452.
  • 35 kV rated per IEEE Standard 404 with 200kV BIL impulse withstand
  • Accommodates 1.370-1.630" cable insulation diameters and 1000 kcmil aluminum conductors
  • Fully shielded, fully submersible molded rubber housing with 500 lb pull resistance
  • Molded conductive shield provides indestructible ground shield for deadfront construction
  • Grounding eye for direct shield grounding; eliminates taping during installation

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
1000 kcmil
Conductor Size
1000 kcmil
Connection
Compression
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Series
Style 1
Size
14-3/8 inch long
Size
14-3/8 X 2-25/32 inches, Cable Insulation Diameter - 1.370-1.630 inches
Size
14-3/8 x 2-25/32 inches
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.

35PCJ1N1410

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

35PCJ1N1330

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 500. Cold-Shrinkable Jacket Seal Included.

35PCJ1N1330-S

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 500. Cold-Shrinkable Jacket Seal Included.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size P Bore Diameter at Jacket/Insulation Transition 1.570. Connector Type - Copper, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1P240PNDNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size P Bore Diameter at Jacket/Insulation Transition 1.570. Connector Type - Copper, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390. Connector Type - Copper, Connector Code 30P - Conductor Diameter Range - .636-.686 inch (16.15-17.42mm), Heatsink Size/Bore - E - .921 inch Diameter. Type Shield - B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink

69TCJS1N230PEBNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390. Connector Type - Copper, Connector Code 30P - Conductor Diameter Range - .636-.686 inch (16.15-17.42mm), Heatsink Size/Bore - E - .921 inch Diameter. Type Shield - B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4, Housing Size 5, 4Q

69TCJN4-5-4Q

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4, Housing Size 5, 4Q
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750.

69TCJS1-Q-Q

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size P Bore Diameter at Jacket/Insulation Transition 1.570. Housing only

69TCJS1-P-Q

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size P Bore Diameter at Jacket/Insulation Transition 1.570. Housing only

Frequently Asked Questions

Can copper compression connectors be used with aluminum conductors?

No, copper compression connectors are suitable for splicing copper-to-copper conductors only and should not be used on aluminum conductors.

What are the available voltage classes for PCJ power cable joints?

PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What conductor types and sizes are compatible with PCJ joints?

PCJ joints can be used with copper or aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

What are the two styles of PCJ joints and their applications?

Style 1 is for straight splicing of two similar cables. Style 2 has separate cable adapters for transition splicing between two different cable sizes.

What installation environments are suitable for PCJ power cable joints?

PCJ power cable joints provide a permanent, fully shielded, fully submersible splice suitable for direct-burial, underground vault, and overhead applications.

What is the maximum pull force the pin-and-socket interlock withstands?

The pin-and-socket interlock on PCJ power cable joints is designed to withstand a pull force of up to 500 lb.

What safety standards do PCJ power cable joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

What is the continuous current rating for PCJ power cable joints?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

What is the short-time current rating for PCJ power cable joints?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What is the phase-to-ground voltage for a 35 kV class PCJ joint?

For a 35 kV class PCJ joint, the phase-to-ground voltage is 20.2 kV.

How to Install the 15/25/35PCJ1 Series Straight Joint

This guide provides step-by-step instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ1 series straight joint for wire shielded cables.

Estimated time: 2h

Tools needed:

Wire strippers, Cutting tool, Wire-brush (for aluminum conductors), Crimping tool, T&B WT3D tool (for 35kV DELTECt Cable ties)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), User-supplied connector, DELTECt Cable ties (TYD5135, for 35kV ONLY), #14 AWG copper wire or equivalent (if needed)

  1. Perform Safety Checks and Initial Inspection

    De-energize all apparatus before beginning. Inspect all components for damage, rating, and compatibility with mating parts. Ensure all required tools are at hand and maintain cleanliness throughout the procedure.

  2. Prepare Cables for Joint Centerline

    Overlap both cables and cut to 12 inches (305mm) from the joint centerline. Remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Cut both cables at the joint centerline.

  3. Prepare Cable 1 and Store Housing

    Taper the edge of Cable 1 insulation from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the housing onto Cable 1 up to the shield wires for temporary storage.

  4. Remove Cable Insulation and Shield

    Carefully remove the cable insulation and then the insulation shield from both cables, referring to the document for specific 'X' and 'Y' dimensions based on conductor size. DO NOT cut or nick the cable insulation or conductor during this process.

  5. Install and Crimp the Splice

    If conductors are aluminum, wire-brush them and immediately insert into the splice. Crimp the splice following its recommendations. Wipe off any excess inhibitor. Check dimensions against the 'Max Check Before' and 'Max Check After' tables in the document. Remove sharp protrusions/burrs and metal chips/filings from the splice and joint assembly area.

  6. Clean and Lubricate Cables for Housing

    Clean the cables where indicated in the diagram. Lubricate the cables in the direction of the arrows to create a build-up or ramp of lubricant at the edge of the insulation shield, as shown in the installation diagram.

  7. Position the Joint Housing

    Slide the housing into its final position. Ensure proper positioning by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield, as depicted in the diagram.

  8. Secure 35kV Joints (If Applicable)

    For 35kV ONLY: Install two DELTECt Cable ties on each end of the cable entrance, 1/4 inch (6mm) from the splice edge and 1/4 inch (6mm) from the first, with offset locking heads. Use the T&B WT3D tool to tighten and trim. Remove and discard the yellow pin from the joint grounding eye.

  9. Connect Grounding and Shield Wires

    Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If smaller, use separate #14 AWG copper wire. Connect joint grounding wires and remaining shield wires using an appropriate user-supplied connector.

  10. Reconstruct Cable Jacket

    Reconstruct the cable jacket (where applicable) over both cables and the joint housing to complete the installation and provide environmental protection.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.