ABB - Installation Products 35PCJ1M2330 - 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 500.

ABB Installation Products 35PCJ1M2330 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786643066


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 35kV Power Cable Joint, SKU 35PCJ1M2330, is designed for reliable termination of single-conductor, copper-conductor power cables. It features a single-piece housing for simplified installation and robust protection. The joint is engineered to accommodate cable insulation diameters ranging from 1.370 inches to 1.630 inches, making it suitable for 500 AWG stranded copper conductors. This product is part of ABB's Installation Products catalog, known for its quality electrical components. The single-piece housing design minimizes potential leak paths and ensures a secure, watertight seal, critical for maintaining cable integrity in various industrial and utility environments. Its construction is focused on providing a dependable connection for medium-voltage power distribution systems. The specified insulation diameter range ensures compatibility with a common size of high-capacity copper conductor used in power transmission and distribution networks. This joint style is appropriate for applications requiring a straightforward and effective method for splicing or terminating 35kV rated cables.
  • 35kV Voltage Rating
  • Single Piece Housing Design
  • Cable Insulation Diameter: 1.370" - 1.630"
  • For 500 AWG Stranded Copper Conductors
  • ABB Installation Products

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
500 kcmil
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.7500 L
Package Weight (Metric)
0.7940 kg
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 500.

35PCJ1M1310

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 500.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Solid 500.

35PCJ1N1310

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Solid 500.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Solid 750.

35PCJ1N1360

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Solid 750.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.

35PCJ1N1410

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000.

25PCJ1N2410

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. DP0597059.

25PCJ2-DP0597069

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. DP0597059.
35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240. Cold Shrinkable Jacket Seal included.

35PCJ1M1310S

35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240. Cold Shrinkable Jacket Seal included.
35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 700/750, Solid 900.

35PCJ1M1380

35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 700/750, Solid 900.

Frequently Asked Questions

What safety standards do PCJ joints meet?

The shield design meets IEEE 592 standard, and connectors meet ANSI 119.4 Class A and Class 3 ratings.

What is the DC withstand voltage during installation?

The DC withstand voltage during installation is 56 kV for 15 kV class, 80 kV for 25 kV class, and 100 kV for 35 kV class.

What is the short-time current rating?

The short-time current rating is equal to that of the cable rating, up to 35 kA.

What is the continuous current rating of the joint?

The continuous current rating of the PCJ power cable joint is equal to that of the cable rating.

What type of connector is needed for copper-to-copper splices?

An all-copper compression connector is required for copper-to-copper connections. Copper connectors should not be used on aluminum conductors.

What types of cable splicing do PCJ joints support?

PCJ power cable joints support straight splicing of two similar cables or transition splicing of different cable sizes up to 1250 kcmil.

Where can Elastimold PCJ power cable joints be installed?

PCJ power cable joints can be installed in direct-burial, underground vault, and overhead applications, providing a permanent, fully shielded, fully submersible splice.

What conductor materials and sizes are compatible?

PCJ power cable joints are compatible with copper or aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

What voltage classes are PCJ power cable joints available in?

PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

Where can Elastimold PCJ power cable joints be installed?

PCJ power cable joints can be installed in direct-burial, underground vault, and overhead applications, providing a permanent, fully shielded, fully submersible splice.

How to Install the 35PCJ1 Straight Joint

This guide provides step-by-step instructions for the permanent installation of the 35PCJ1 straight joint, designed for joining aluminum to aluminum or aluminum to copper wire-shielded cables. This joint is fully shielded, fully submersible, and requires careful adherence to safety protocols. All apparatus must be de-energized during installation.

Estimated time: 2h

Tools needed:

Wire strippers, Utility knife, Wire brush, Crimping tool, T&B WT3D tool (for 35kV only)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Appropriate connector (user supplied), DELTECt Cable ties (TYD5135, for 35kV only), No. 14 AWG copper wire or equivalent (if shield wires are smaller than #14 AWG)

  1. Prepare for Installation and Ensure Safety

    Before beginning, ensure all apparatus in the work area are de-energized. Do not touch or move energized products. Inspect all parts for damage, correct rating, and compatibility with mating parts. Check the package contents to ensure completeness and read these instructions entirely. Have all required tools at hand and maintain cleanliness throughout the procedure.

  2. Prepare Cables for Joint Centerline

    Overlap both Cable 1 and Cable 2, then cut them to 12 inches (305mm) from the intended center line of the joint. This ensures sufficient length for the shield wires to be rejoined later. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires on both cables. Finally, cut both cables precisely at the center line of the joint.

  3. Prepare Cable 1 and Store Housing

    Taper the edge of Cable 1's insulation for at least 1/2 inch (13mm) but no more than 1-1/2 inches (38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Carefully slide the joint housing onto Cable 1, pushing it up to the shield wires. This procedure will not contaminate electrical interfaces.

  4. Prepare Cables for Splice Installation

    Carefully remove the cable insulation from both Cable 1 and Cable 2 according to the specified dimensions (e.g., 'Y' and 'X' dimensions from the diagram, which are 2 1/2" or 2 3/8" for 'Y' and 6 1/4" or 6 3/8" for 'X' depending on conductor size). Then, carefully remove the insulation shield from both cables. IMPORTANT: DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR during this process.

  5. Install the Splice

    If the conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Check the dimension between the cable insulations against the 'Max Check Before' table (6" or 6 7/8" depending on conductor size); if it exceeds, redo the assembly. Crimp the splice following the recommendations provided with the splice kit. Wipe off any excess inhibitor. Re-check the distance between cable insulations against the 'Max Check After' table (6 1/4" or 6 1/2"); if it exceeds, redo the assembly. Remove any sharp protrusions or burrs generated during crimping and ensure all metal chips/filings are removed from the splice and joint assembly area before sliding the joint.

  6. Clean and Lubricate for Final Assembly

    Clean the cables where indicated in the installation diagrams. Lubricate the cables in the direction of the arrows shown in the diagram. This technique is crucial to provide a build-up or ramp of lubricant at the edge of the insulation shield, aiding in the smooth and proper seating of the joint housing.

  7. Complete Joint Assembly and Grounding

    Slide the joint housing into its final position. Ensure proper positioning by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV installations ONLY: Install two DELTECt Cable ties (TYD5135) on each end of the cable entrance. Place the outer ties approximately 1/4 inch (6mm) from the splice edge, and the second ties approximately 1/4 inch (6mm) from the first, with offset locking heads. Use the T&B WT3D tool to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.