ABB Installation Products 35PCJ1M2310 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786486830
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV voltage rating for medium-voltage applications
- Single-piece housing for simplified installation
- Accommodates 1.370" to 1.630" cable insulation diameter
- Designed for 500 AWG solid copper conductors
- Part of ABB Installation Products line
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 500 kcmil |
Connection | Compression |
Insulation | Yes |
Material | Copper |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Size | 14-3/8 inch long |
Size | Cable Insulation Diameter 1.370 inch to 1.630 inch |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.5000 L |
Package Weight (Metric) | 1.1340 kg |

35PCJ1K1330
35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 500 /Solid 600 /mmSquared 250/300.
35PCJ1M2330
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 500.
35PCJ1N1310
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Solid 500.
35PCJ1N1360
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Solid 750.
35PCJ1N1410
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.
25PCJ1N2410
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000.
25PCJ2-DP0597069
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. DP0597059.
35PCJ1M1310S
35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240. Cold Shrinkable Jacket Seal included.Frequently Asked Questions
What are the available voltage classes?
Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
What is the short-time current rating?
The short-time current rating is equal to that of the cable rating, up to 35 kA.
Can copper connectors be used on aluminum conductors?
No, copper compression connectors are suitable for copper-to-copper connections only and should not be used on aluminum conductors.
What is the pull force resistance of the interlock?
The pin-and-socket interlock design of the PCJ power cable joints can withstand a pull force up to 500 lb.
What is the DC withstand during installation for 15 kV?
For the 15 kV class, the DC withstand during installation is 56 kV.
What is the corona extinction voltage for 25 kV class?
For the 25 kV class, the corona extinction voltage with 3 pC sensitivity is 22 kV.
What is the BIL impulse withstand for 35 kV class?
For the 35 kV class, the BIL impulse withstand (1.2 x 50 µsec. wave) is 300 kV.
What is the continuous current rating?
The continuous current rating for PCJ power cable joints is equal to that of the cable rating.
What environments are suitable for installation?
These splices are permanent, fully shielded, and fully submersible. They can be installed in direct-burial, underground vault, and overhead applications.
What is the maximum conductor size supported?
Elastimold PCJ power cable joints can accommodate conductor sizes up to 1250 kcmil.
How to Install the 15/25/35PCJ1 Series Straight Joint
This guide provides detailed instructions for installing the 15/25/35PCJ1 series straight joint, a permanent, fully shielded, and submersible solution for connecting wire shielded cables. It covers essential cable preparation, splice installation, and final assembly steps.
Estimated time: 2h
Tools needed:
Wire strippers, Measuring tape, Wire brush, Crimping tool (as per splice recommendations), T&B WT3D tool (for 35kV only)
Supplies needed:
Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Appropriate connector (for grounding wires), DELTECt Cable ties (TYD5135, for 35kV only), #14 AWG copper wire or equivalent (if shield wires are smaller)
- Ensure Safety and Inspect Components
De-energize all apparatus in the work area before beginning installation. Do not touch or move energized products. Inspect all parts for damage, proper rating, and compatibility with mating parts and cables. Ensure all required tools are at hand and maintain cleanliness throughout the procedure.
- Prepare Cables for Jointing
Overlap both cables and cut them to 12 inches (305mm) from the joint's centerline to ensure sufficient shield wire length. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Finally, cut both cables at the joint's centerline.
- Prepare Cable 1 and Store Housing
Taper the edge of Cable 1 at least 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Slide the housing onto Cable 1, pushing it up to the shield wires.
- Prepare Cables for Splice Installation
Carefully remove the cable insulation and then the insulation shield from both cables according to the dimensions below. For 500-750 MCM conductors, remove insulation to "X" = 2-1/2 inches (64mm) and insulation shield to "Y" = 6-1/4 inches (159mm). For 1000 MCM conductors, remove insulation to "X" = 2-3/8 inches (68mm) and insulation shield to "Y" = 6-3/8 inches (162mm). DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR.
- Install the Splice
If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Crimp the splice following the recommendations provided with it. After crimping, wipe off all excess inhibitor. Verify the distance between cable insulations: for 500-750 MCM, it should not exceed 6-1/4 inches (159mm); for 1000 MCM, it should not exceed 6-1/2 inches (165mm). Remove any sharp protrusions or burrs generated during crimping, ensuring all metal chips are cleared from the splice and joint assembly area. Clean the cables where indicated and lubricate in the direction of the arrows to build up a ramp of lubricant at the edge of the insulation shield.
- Complete Joint Assembly and Grounding
Slide the housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV ONLY, install two DELTECt Cable ties (TYD5135) on each end of the cable entrance, approximately 1/4 inch (6mm) from the edge of the splice and then 1/4 inch (6mm) from the first, with offset locking heads. Use a T&B WT3D tool to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.