ABB Installation Products 35-MTB1-C Kellums grip bracket fits overall cable O.D. from 0.89 inch to 1.185 inch
UPC: 783786657919
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Designed for cable O.D. from 0.89 inch to 1.185 inch
- Provides secure cable grip and strain relief
- Manufactured by ABB - Installation Products
- SKU: 35-MTB1-C
- Suitable for industrial cable management applications
Specifications
Application | Terminator Mounting Bracket |
Material | Galvanized Steel |
Mounting | Mechanical |
Size | Fits overall cable O.D. from 0.89 inch to 1.185 inch |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Mounting Bracket |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.0010 L |
Package Weight (Metric) | 0.0010 kg |

K650CAM-OK
Operating Kit 25kv Cam-Op, includes accessories that enable visible break, testing isolation and grounding functions to be preformed. Kit includes - (3) Cam-Op Loadbreak Tap Plugs, (3) Grounding Elbows, (1) Assembly Tool, (1) Test Rod, (1) Carry Case, (1) Lubricant and (1) Set of Instructions.Frequently Asked Questions
What outer jacket size is for ordering number 35MTB1-B?
The ordering number 35MTB1-B is for a KELLUMS GRIP Bracket with an outer jacket size of .925 in to 1.335 in.
How do I order a KELLUMS GRIP Bracket?
To order a KELLUMS GRIP Bracket, specify 35MTB1-A, 35MTB1-B, 35MTB1-C, or 35MTB1-D.
What is included in a KELLUMS GRIP Bracket kit?
Each kit contains one KELLUMS GRIP Bracket (e.g., 35MTB1-T) and one Installation Instruction IS-0145.
What are the main features of the KELLUMS GRIP Bracket?
Key features include mounting cables on riser poles, releasing mechanical stress on the cable, and a flexible stainless steel connector grip.
Which terminators are compatible with the KELLUMS GRIP Bracket?
It is compatible with PCT-1, PCT-2, 16THG, 16THGS, MTG, MTG1, and MSC Terminators.
What is the purpose of the KELLUMS GRIP Bracket?
The KELLUMS GRIP Bracket mounts a premolded rubber terminator and supports the cable entering it. It is used for mounting cables on riser poles.
What is the purpose of the KELLUMS GRIP Bracket?
The KELLUMS GRIP Bracket mounts a premolded rubber terminator and supports the cable entering it. It is used for mounting cables on riser poles.
What outer jacket size is for ordering number 35MTB1-B?
The ordering number 35MTB1-B is for a KELLUMS GRIP Bracket with an outer jacket size of .925 in to 1.335 in.
How do I order a KELLUMS GRIP Bracket?
To order a KELLUMS GRIP Bracket, specify 35MTB1-A, 35MTB1-B, 35MTB1-C, or 35MTB1-D.
What is included in a KELLUMS GRIP Bracket kit?
Each kit contains one KELLUMS GRIP Bracket (e.g., 35MTB1-T) and one Installation Instruction IS-0145.
How to Install the 35MTB1-T Bracket Assembly
This guide provides step-by-step instructions for installing the 35MTB1-T bracket assembly, which is designed for mounting a premolded rubber terminator and supporting its cable. DANGER: All apparatus must be de-energized during installation. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.
Estimated time: 1h
Tools needed:
Wrench, Wire strippers, Measuring tape, Cleaning supplies
Supplies needed:
Bolts (supplied with bracket), Weather-proof plastic tape, Premolded rubber terminator, Cable
- Ensure Safety and Prepare
Before starting, ensure all apparatus is de-energized. Read the entire installation instructions, check package contents for completeness and damage, and verify all components fit properly with the cable and/or mating products. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Mount Connector Grip to Bracket
Attach the connector grip to a suitable bracket using the bolts supplied with the bracket. Ensure the connection is secure and stable.
- Prepare Cable and Concentric Neutral Wires
For cables with extruded semi-conducting shields and concentric neutral wires, tie back the concentric neutral wires to the length specified in the terminator instructions plus dimension 'X' from the provided table. Prepare the cable as required for installing the terminator.
- Feed Prepared Cable Through Grip
Feed the prepared cable through the connector grip until the semi-conducting shield extends at least 1-3/4 inches (45 mm) above the connector grip.
- Apply Weatherproof Tape
Apply weatherproof plastic tape approximately two inches (50 mm) from the bottom end of the wire grip. Tightly wrap the tape with a one-half tape width overlap, moving 'down' the grip approximately one inch (25 mm) onto the cable.
- Clean Cable and Install Terminator
Clean the outer jacket and the exposed cable insulation above the connector grip. Then, install the premolded rubber terminator according to the specific instructions packed with the terminator itself.
- Ground All Components
Ensure that the concentric neutral from the cable(s), the electrostatic drain wire(s) from the terminator(s), and the mounting bracket are all properly grounded to prevent electrical hazards.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.