ABB - Installation Products 274FLR3-A0220 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

ABB Installation Products 274FLR3-A0220 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port…

UPC: 783786792993


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 274FLR3-A0220 Molded Current Limiting Fuse Housing is engineered for reliable operation within electrical distribution systems. This housing is designed to accommodate current limiting fuses and features a nominal fuse voltage rating of 17.2kV, making it suitable for medium voltage applications. Key features include two capacitive test ports, facilitating safe and efficient testing of fuse status and system integrity. The large housing design accommodates a broad range of cable insulation diameters, specifically from 0.575 inches to 0.740 inches (15-19mm). For conductor connections, this housing supports aluminum conductors, including 2 AWG stranded compressed and 1 AWG solid compact sizes. Manufactured by ABB - Installation Products, this component is built to meet the demands of industrial electrical infrastructure. Its robust construction and specific electrical ratings ensure dependable performance and protection for connected equipment. The SKU 274FLR3-A0220 signifies a product designed for critical electrical safety and operational continuity. This fuse housing plays a vital role in protecting circuits from overcurrents and short circuits, thereby preventing damage to transformers, switchgear, and other sensitive electrical apparatus.
  • Molded Current Limiting Fuse Housing
  • Nominal Fuse Voltage Rating: 17.2kV
  • Features Two Capacitive Test Ports
  • Accommodates Cable Insulation Diameter: 0.575" - 0.740" (15-19mm)
  • Supports Aluminum Conductors: 2 AWG Stranded Compressed, 1 AWG Solid Compact

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Insulation
True
Length
21.12 in
Length
536.448 mm
Material
EPDM-Rubber
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 25/28kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector with Test Point
Voltage Rating
15.5 to 16.2 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit

168FLR1-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

274FLR3-B0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Bi-Metal Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact.

274FLR1A5240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Bi-Metal Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

274FLR1-C0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact

274FLR1-C0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded Compressed

274FLR1-D0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded Compressed
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Aluminum Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

274FLR1-A0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Aluminum Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact.

274FLR1-C5240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact.

Frequently Asked Questions

What is the nominal fuse voltage rating for this housing?

The nominal fuse voltage rating for the ABB 274FLR3-A0220 is 17.2kV.

What cable insulation diameters does this fuse housing accommodate?

This housing accommodates cable insulation diameters ranging from 0.575 inches to 0.740 inches (15-19mm).

What types of aluminum conductors can be used with this housing?

This housing supports 2 AWG stranded compressed and 1 AWG solid compact aluminum conductors.

How many capacitive test ports does this fuse housing have?

The ABB 274FLR3-A0220 features two capacitive test ports.

Who is the manufacturer of the 274FLR3-A0220 fuse housing?

The manufacturer of the 274FLR3-A0220 fuse housing is ABB - Installation Products.

How to Install the 274FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the safe and proper installation of the 274FLR Loadbreak Fused Elbow Connector, including cable preparation, assembly, and neutral connections.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Torque-limiting Allen Wrench, Wire brush, Crimp tool, Wire strippers, Cutting tool, Hotstick

Supplies needed:

Cable Half Housing, Elbow Half Housing, Fuse, Compression Lug, Probe, Probe Connector, Hose Clamp, Lubricant, No. 14 AWG (2.5mm) Copper wire, Grounding connector, 200ECS Cold Shrink Cable Seal (optional)

  1. Perform Safety Checks and Prepare Workspace

    Ensure all apparatus is de-energized before beginning installation. Verify that all components are undamaged, rated correctly, and compatible with mating parts. Gather all required tools and maintain a clean work area. This product must be installed by competent personnel trained in high-voltage safety practices.

  2. Prepare the Cable

    Cut excess cable to 20 inches minimum beyond the bushing centerline. Remove the cable jacket for a length of 'A' (15-3/4 inches for 274FLR-3) plus 7-3/8 inches from the bushing centerline. Unwrap and fold concentric neutral wires back over the jacket, then bind them. Squarely cut the cable end 1-1/8 inches, taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately crimp the compression lug, rotating 180 degrees for successive crimps. Remove the insulation shield 5-1/2 inches from the lug end, beveling the insulation 1/8 inch maximum. Thoroughly clean the insulation.

  3. Lubricate and Assemble Cable Half with Connector and Fuse

    Apply the supplied lubricant to the outside of the compression lug, cable insulation, conductive shield, and the cable entrance end of the Fused Elbow cable half. Insert the compression lug and cable into the cable half until the top end of the lug protrudes beyond surface 'A'. Insert the threaded terminal end of the fuse into the cable half and hand-tighten it into the cable connector. CAUTION: Do not overtighten the fuse stud to prevent fracture. Pull the housing up against the bottom of the tightened fuse.

  4. Install and Secure the Probe Connector

    Assemble the probe connector to the fuse terminal. Rotate the probe connector so its flats are perpendicular to the mating bushing. Lock the probe connector in position by tightening the setscrews using the supplied torque-limiting Allen wrench. Rotate the cable half of the Fused Elbow so that its test point is perpendicular to the flats on the probe connector.

  5. Assemble Elbow Halves and Insert Probe

    Apply the supplied lubricant to the elbow half of the fused elbow. Assemble the elbow half to the cable half, ensuring the cuff of the cable half overlaps the elbow half by 3/4 inch. Verify the probe connector faces the opening of the fused elbow half and that both test points are aligned. Insert the probe into the probe connector, pushing on the cable if necessary to align. Hand-start the threads, then tighten using the supplied torque-limiting Allen wrench until it bends and remains bent. Position and tighten the hose clamp, but do not overtighten.

  6. Connect Concentric Neutral Wires

    Using a separate No. 14 AWG (2.5mm) copper wire, insert one end through each grounding eye on the elbow housing and cable housing. Twist tightly, taking care not to damage the eyes. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation.

  7. Connect the Fused Elbow to the Bushing

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. IMPORTANT: Only lubricate if the transformer and elbow are confirmed to be de-energized. Use a fully insulated hotstick tool to operate the connector. DO NOT OPERATE BY HAND. Follow company safe work practices for hotstick operation and length.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.