ABB - Installation Products 168RLR-K-5270 - 200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

ABB Installation Products 168RLR-K-5270 200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation…

UPC: 783786531998


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 168RLR-K-5270 Loadbreak Replacement Elbow Connector is a fully rated 15kV, 200 Amp Class loadbreak elbow designed for medium-voltage electrical distribution systems. The 168RLR-K-5270 is engineered to connect to 15kV Class, 95kV BIL apparatus, making it ideal for repair applications where cables must be stripped back and a new compression lug applied. It supports cable insulation diameters from 1.090 inches to 1.310 inches (27.69 mm to 33.27 mm), ensuring compatibility with AWG Compressed Stranded 4/0, Solid 250, and mm² 126.67 conductors. The connector includes a non-corrosive capacitive test point for system diagnostics and maintenance without disconnecting the primary circuit. Its fully shielded, fully submersible molded rubber housing meets ANSI/IEEE Standard 386, with ratings including 8.3kV max phase-to-ground operating voltage, 14.4kV max phase-to-phase, and 10kA symmetrical momentary & fault close capability. The 168RLR-K-5270 also features provisions for hot stick operation and ground wire connection, enhancing safety and installation flexibility. Typical applications include repairing failed elbow connections, gaining extra cable length, or converting live front to dead front equipment without changing the cable.
  • 200 Amp, 15kV Class loadbreak elbow connector
  • Extended length housing and compression lug (+8-7/8 inches / 225.4 mm)
  • Cable insulation diameter range: 1.090"–1.310" (27.69–33.27 mm)
  • Supports AWG 4/0 Compressed Stranded, Solid 250, and mm² 126.67 conductors
  • Non-corrosive capacitive test point for diagnostics without disconnection

Specifications

Amperage Rating
200 A
Application
Designed for connecting to and operating 15kV Class, 95kV BIL apparatus
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 1.090 inch to 1.310 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended Length Housing and Compression Lug - plus 10-1/2 inch (266.7mm). Non-Corrosive Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Replacement Elbow Connector with Test Point
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-D5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

168ELR88110-5240

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.665 inch to 0.895 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

168ELR-6689-5240

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.665 inch to 0.895 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes a copper compression lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SP-B2240

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes a copper compression lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. 200ECS-G3 Jacket Seal and Grounding Kit Included. Includes 02800X Bi-Metal Contact.

167LRT-G5210-SG3

200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. 200ECS-G3 Jacket Seal and Grounding Kit Included. Includes 02800X Bi-Metal Contact.
15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SR-B2240

15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Includes 02800X Bi-Metal Contact.

167LRT-F5270

200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Includes 02800X Bi-Metal Contact.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

K151SP-A2230

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

Frequently Asked Questions

What conductor sizes are compatible with this connector?

It is compatible with AWG Compressed Stranded 4/0, Solid 250, and mmSquared 126.67 conductor sizes.

What is the maximum voltage rating for this elbow connector?

The ABB 168RLR-K-5270 loadbreak elbow connector has a voltage rating of 15kV.

What is the current rating of the 168RLR-K-5270 connector?

This loadbreak elbow connector is rated for 200 Amps.

What cable insulation diameters can this connector accommodate?

The connector is designed for cable insulation diameters ranging from 1.090 inches to 1.310 inches.

What type of lug material is used in this connector?

The ABB 168RLR-K-5270 features a bi-metal compression lug for reliable connections.

Does this elbow connector have a test point?

Yes, this loadbreak replacement elbow connector includes a test point for diagnostics.

How to Install the 168RLR Loadbreak Replacement Elbow Connector

This guide provides step-by-step instructions for installing the 168RLR Loadbreak Replacement Elbow Connector, converting a livefront termination to deadfront for UD cable. Ensure all apparatus is de-energized before beginning installation.

Estimated time: 1h 30m

Tools needed:

Cable cutting tool, Cable insulation removal tool, Wire brush, Crimping tool, Probe wrench, Pliers, Hotstick

Supplies needed:

Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, do not substitute), Hose Clamp, No. 14 AWG (2.5mm) copper wire, Appropriate ground connector, Silicone grease (for test point cap)

  1. Prepare for Installation and Ensure Safety

    DANGER: All apparatus must be de-energized during installation or removal of part(s). Failure to follow these instructions will result in damage to the product and serious or fatal injury. Check contents of package to ensure they are complete and undamaged. Check all components for proper fit with cable and/or mating products. Thread the probe into the compression lug to check threads; if resistance is encountered, check for damage and replace. Have all required tools at hand and maintain cleanliness throughout the procedure.

  2. Remove Existing Livefront Termination

    Remove the rubber cap from the existing terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Remove the terminator housing from the cable.

  3. Prepare the Cable

    Train cables to be straight and in-line with the bushing centerline. Measure 10-1/2 inches from the bushing centerline and cut the cable squarely to this length. Remove 1-3/8 inches of cable insulation from the end of the cable, cutting squarely. DO NOT NICK THE CONDUCTOR. If the insulation shield measures less than 6-1/2 inches, proceed. If greater, consult an ELASTIMOLD representative.

  4. Install and Crimp the Compression Lug

    Wire brush the bare aluminum conductor immediately. Install the compression lug onto the conductor, rotating it to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug starting at the crimp line mark, rotating 180 degrees for each successive crimp (refer to the crimp chart packaged with the compression lug). Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  5. Assemble the Elbow Housing and Probe

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE. Other lubricants may be harmful to this product or its mating product(s). Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  6. Connect the Concentric Neutral

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation. Add the supplied hose clamp as shown in the diagram, tightening it snugly without overtightening.

  7. Connect the Elbow to the Bushing Plug and Lubricate Test Point Cap

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Securely fasten a hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle area over the bushing plug, inserting the elbow male contact into the bushing until slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface. For 168RLR models, lubricate the test point cap with silicone grease and assemble it tightly onto the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.