Authorized ABB Distributor (Installation Products)
ABB - Installation Products 25PCJ1P1440-S - 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size Stranded/Compressed 1250 kcmil. Includes Cold-Shrinkable Jacket Seal.

ABB Installation Products 25PCJ1P1440-S 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 075114398206


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products 25PCJ1P1440-S is a 25kV power cable joint designed for medium-voltage distribution systems. This joint accommodates aluminum conductors sized at 1250 kcmil with stranded/compressed construction, ensuring reliable electrical continuity in high-voltage circuits. The single-piece housing simplifies installation by eliminating multiple components, reducing assembly time and potential error points. The integrated cold-shrinkable jacket seal provides a moisture-resistant barrier, protecting the joint from environmental contaminants and maintaining dielectric integrity over time. The joint is rated for cable insulation diameters between 1.725 inches and 1.935 inches, making it suitable for applications where precise dimensional compatibility is required. This product is commonly used in utility substations, industrial power distribution networks, and renewable energy installations where medium-voltage cable systems demand durable, low-maintenance joints. The aluminum conductor design ensures compatibility with standard utility-grade cable systems while offering cost-effective performance.
  • 25kV rated medium-voltage cable joint
  • Accommodates 1250 kcmil stranded/compressed aluminum conductors
  • Single-piece housing for simplified installation and reduced error points
  • Cold-shrinkable jacket seal for moisture resistance and dielectric protection
  • Compatible with cable insulation diameters from 1.725" to 1.935"

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
1250 kmcil
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
15-3/4 in long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other severe service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV, Power Cable Joint with Single Piece Housing. Copper Conductor. Cable Insulation Diameter Range 1.515 to 1.780 inch, Conductor Size 1250 Compressed/Stranded. No Sealing Kit.

15PCJ1-N2440

15kV, Power Cable Joint with Single Piece Housing. Copper Conductor. Cable Insulation Diameter Range 1.515 to 1.780 inch, Conductor Size 1250 Compressed/Stranded. No Sealing Kit.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Side A Cable Insulation Diameter 0.750 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded/Compressed 1/0 or Solid/Compact 2/0. Side B Cable Insulation Diameter 0.750 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded/Compressed #1 or Solid/Compact 1/0.

15PCJ2G1240-G1230

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Side A Cable Insulation Diameter 0.750 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded/Compressed 1/0 or Solid/Compact 2/0. Side B Cable Insulation Diameter 0.750 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded/Compressed #1 or Solid/Compact 1/0.
15kV Power Cable Joint Splice - Style 2 with Universal Housing and Separate Cable Adapters. H1270 - Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. G1250 - Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 or Solid 3/0. No Sealing Kit.

15PCJ2H1270G1250

15kV Power Cable Joint Splice - Style 2 with Universal Housing and Separate Cable Adapters. H1270 - Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. G1250 - Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 or Solid 3/0. No Sealing Kit.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 250 kcmil or Solid 300 kcmil.

25PCJ1L1280

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 250 kcmil or Solid 300 kcmil.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. (A) Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 or Solid 250. (B) Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 or Solid 2/0.

25PCJ2J1270-H1240

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. (A) Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 or Solid 250. (B) Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 or Solid 2/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded / Compressed 300 kcmil or Solid / Compact 350 kcmil. Installation Dies 470 251 980 83 B11CH CSA 26. Cold-Shrinkable Jacket Seal Included.

15PCJ1-J1290-S

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded / Compressed 300 kcmil or Solid / Compact 350 kcmil. Installation Dies 470 251 980 83 B11CH CSA 26. Cold-Shrinkable Jacket Seal Included.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size Stranded / Compressed 1250 kcmil.

15PCJ2N2440

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size Stranded / Compressed 1250 kcmil.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 500.

25PCJ1L2310

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 500.

Frequently Asked Questions

How are transition joints catalog numbers constructed?

When constructing a catalog number for a transition joint, list the larger connector first and the smaller connector second.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What types of conductors are compatible with PCJ joints?

PCJ power cable joints can be used with both copper and aluminum conductors, accommodating a wide range of sizes up to 1250 kcmil.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

What is the maximum conductor size supported by PCJ joints?

Elastimold PCJ power cable joints can accommodate conductor sizes up to 1250 kcmil.

What environments are suitable for PCJ joint installation?

PCJ power cable joints provide a permanent, fully shielded, fully submersible splice suitable for direct-burial, underground vault, and overhead applications.

What is the continuous current rating of PCJ joints?

The continuous current rating of PCJ power cable joints is equal to that of the cable rating.

What is the short-time current rating of PCJ joints?

The short-time current rating is equal to that of the cable rating, up to 35 kA.

What is the purpose of the grounding eye on PCJ joints?

The grounding eye provides a convenient point to connect a ground wire to the molded conductive shield, placing the shield at ground potential.

Do PCJ joints require taping during installation?

No, the cable entrance engages the insulation shielding of the cable, eliminating the need for taping.

How to Install the 15/25/35PCJ1,NPQ Straight Joint

This guide provides step-by-step instructions for the permanent installation of the 15/25/35PCJ1,NPQ straight joint, designed for wire shielded cables with aluminum or copper conductors. Ensure all safety precautions are followed.

Estimated time: 2h

Tools needed:

Wire strippers, Wire-brush, Crimping tool, T&B WT3D tool (for 35kV only)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), User-supplied connector, Deltect Cable ties (TYD5135, for 35kV only), #14 AWG copper wire or equivalent (if needed)

  1. De-energize Apparatus and Inspect Components

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Inspect the contents of the package to ensure they are complete and undamaged. Check all components for proper fit with the cable and/or mating products.

  2. Prepare Cables for Joint Centerline

    Overlap both cables and cut to 12 inches (305mm) from the center line of the joint to ensure sufficient length of shield wires. Remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires, then cut both cables at the joint centerline.

  3. Prepare Cable 1 and Store Housing

    Taper the edge of Cable 1 at least 1/2 inch to no greater than 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the housing onto Cable 1 up to the shield wires.

  4. Prepare Cables for Splice Installation

    Carefully remove the cable insulation and then the insulation shield from both cables. DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR. Refer to the 'X' and 'Y' dimensions provided in the documentation for precise measurements.

  5. Install the Splice

    If conductors are aluminum, wire-brush them and immediately insert into the splice. Crimp the splice following the recommendations provided with it. Wipe off all excess inhibitor where applicable. Remove any sharp protrusions or burrs generated during crimping, ensuring metal chips/filings are removed from the splice and joint assembly area.

  6. Clean and Lubricate Cables for Housing Slide

    Clean cables where indicated. Lubricate in the direction of the arrows to provide a build-up or ramp of lubricant at the edge of the insulation shield on both Cable 1 and Cable 2.

  7. Slide Housing into Final Position

    Slide the joint housing into its final position. Proper positioning is ensured by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield.

  8. Install 35kV Specific Components (If Applicable)

    For 35kV ONLY: Install two DELTECt Cable ties on each end of the cable entrance. Begin by installing the outer ties approximately 1/4 inch (6mm) from the edge of the splice, then install the second ties approximately 1/4 inch (6mm) from the first with an offset of the locking heads. The T&B WT3D tool is recommended for tightening and trimming. Remove the yellow pin from the joint grounding eye and discard it.

  9. Connect Grounding Wires and Reconstruct Jacket

    Retrain shield wires and secure them to the ends of the joint. Insert one of the shield wires from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket (where applicable) over both cables and the joint housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.