Overview
- 25kV rated power cable joint
- Single piece housing for simplified installation
- Accommodates cable insulation diameter from 1.370" to 1.630"
- Designed for 500 AWG stranded copper conductors
- ABB Installation Products quality and reliability
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 500 kcmil |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Size | 14-3/8 inch long |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

25PCJ1K1330
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 500
25PCJ1M2360
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750.
35PCJ1M1300
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.
35PCJ1M1280-1270
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 250. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
25PCJ1M1360
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 750.
35PCJ1M1310
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 500.
35PCJ1M1330-S
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 500. Cold-Shrinkable Jacket Seal Included.
35PCJ1M1330
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.Frequently Asked Questions
What is the cable insulation diameter range for this joint?
This ABB 25kV Power Cable Joint Style 1 is designed to accommodate cable insulation diameters ranging from 1.370 inches to 1.630 inches.
What conductor size and type is this joint compatible with?
This joint is specifically designed for 500 AWG stranded copper conductors.
What is the voltage rating of this power cable joint?
The ABB 25kV Power Cable Joint Style 1 has a voltage rating of 25kV.
What type of housing does this ABB cable joint feature?
This ABB cable joint features a single-piece housing for simplified installation.
How to Install the 15/25/35PCJ1 Series Cable Straight Joint
This guide provides step-by-step instructions for installing the 15/25/35PCJ1 series permanent, fully shielded, fully submersible straight joint for aluminum to aluminum and/or aluminum to copper conductor, wire shielded cables.
Estimated time: 2h
Tools needed:
Measuring Tape, Cable Jacket Stripper, Cable Insulation Stripper, Wire Brush, Crimping Tool, Cable Tie Tool (optional, for 35kV)
Supplies needed:
15/25/35PCJ1 Series Joint Kit (includes Housing, Splice, Lubricant), Conductor Connector (user supplied), DELTECt Cable Ties (TYD5135, for 35kV only), #14 AWG Copper Wire (if needed for grounding), Grounding Connector, Cable Jacket Repair Material (if applicable)
- Prepare for Installation and Safety
De-energize all apparatus in the work area. Inspect all product parts for damage, rating, and compatibility. Read instructions thoroughly. Gather all required tools and supplies, ensuring a clean work environment. Remove shipping covers and replace with HV insulated caps/connectors before energizing or submerging.
- Prepare Cables for Jointing
Overlap both cables and cut to 12 inches (305mm) from the joint centerline. Remove Cable 1 jacket to 37 inches (940mm) and Cable 2 jacket to 21 inches (530mm), if applicable. Fold back shield wires. Cut both cables precisely at the joint centerline.
- Prepare Cable 1 and Store Joint Housing
Taper Cable 1 insulation edge from 1/2 inch (13mm) to 1-1/2 inches (38mm). Clean and lubricate Cable 1 insulation shield. Lubricate the inside bore of the joint housing on both ends. Slide the joint housing onto Cable 1, pushing it up to the shield wires for temporary storage.
- Prepare Cables for Splice
Carefully remove the cable insulation from both Cable 1 and Cable 2 according to the specified dimensions (e.g., 2 1/2" or 2 3/8" for 'X', 6 1/4" or 6 3/8" for 'Y' depending on conductor size). Carefully remove the insulation shield from both cables. Ensure no cuts or nicks are made to the cable insulation or conductor.
- Install the Splice
If conductors are aluminum, wire-brush them and immediately insert into the splice. Check the conductor insertion dimension against the 'Max Check Before' table; redo if it exceeds. Crimp the splice per recommendations. Wipe off excess inhibitor. Check distance between cable insulations against 'Max Check After' table; redo if it exceeds. Remove sharp protrusions/burrs and metal chips. Clean cables where indicated. Lubricate to create a build-up at the insulation shield edge.
- Complete Joint Assembly and Grounding
Slide the joint housing into its final position, ensuring proper placement by equalizing the deformation of the joint ends. For 35kV ONLY: Install two DELTECt Cable ties on each end (1/4" from splice edge, 1/4" from first tie, offset heads). Remove and discard yellow pin from grounding eye. Retrain shield wires and secure to joint ends. Insert one shield wire from each cable (if #14 AWG or larger) through the grounding eye; use #14 AWG copper wire if smaller. Connect grounding wires and remaining shield wires using an appropriate connector. Reconstruct cable jacket over cables and joint housing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.