
ABB Installation Products 25PCJ1M1300 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786962303
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25kV rated power cable joint for medium-voltage applications
- Style 1 joint with single-piece housing for simplified installation
- Accommodates cable insulation diameters from 1.370 to 1.630 inches
- Designed for 350 AWG stranded aluminum conductors
- Manufactured by ABB Installation Products for reliable performance
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 350 kcmil |
Connection | Compression |
Insulation | Yes |
Material | Aluminum |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Series | 25PCJ1 |
Size | 14-3/8 inch long |
Size | Cable Insulation Diameter 1.370 inch to 1.630 inch, Conductor Size AWG Stranded 350 |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

25PCJ2L1300
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.
25PCJ1H1270
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
35PCJ1L2270
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15PCJ2L2360
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 750.
15PCJ2-M2360-L2310
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 500. Length 21.0 inch x 3.75 inch Diameter.
25PCJ1N1410-0MA
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Metallic Tape Shield Adapter. Replacement part is 600ECS-G3.
15PCJ2F1230
15kv Power Cable Joint, Style 2, Insulation Diameter .640 inch to .820 inch, Aluminum Conductor, Conductor Size 230 - Stranded/Compressed #1, Compact/Solid 1/0.
25PCJ2M2280-J1270
25kV Power Cable Joint/Splice, Universal Housing and Separate Cable Adapters. Side 1 - Cable Insulation Diameter 1.370 to 1.630 inches, Copper Compression Lug, Conductor Size Stranded/Compressed 250. Side 2 - Cable Insulation Diameter .980 to 1.180 inches, Aluminum Compression Lug, Conductor Size Stranded/Compressed 4/0. Solid/Compact 250Frequently Asked Questions
What is the insulation diameter range for this ABB cable joint?
This ABB 25kV Power Cable Joint Style 1 is designed to accommodate cable insulation diameters ranging from 1.370 inches to 1.630 inches.
What conductor size and type is this joint compatible with?
This joint is compatible with 350 AWG stranded aluminum conductors.
What is the voltage rating of this ABB cable joint?
This ABB Power Cable Joint is rated for 25kV.
What style of joint is the 25PCJ1M1300?
The 25PCJ1M1300 is a Style 1 joint with a single-piece housing.
How to Install the 25PCJ1M1300 Straight Joint
Installation guide for creating a permanent, fully shielded, and submersible straight joint for aluminum and/or copper conductor wire shielded cables.
Estimated time: 1h
Tools needed:
Wire brush, Crimping tool, Cable ties tightening tool (for 35kV only)
Supplies needed:
Joint Housing, Splice (Conductor Contact), Lubricant, Appropriate connector for grounding wires, DELTECt Cable ties (for 35kV only), Insulated cap(s) or connector(s) (if supplied with protective shipping cover)
- Prepare Cables for Joint
Overlap both cables and cut to 12" (305mm) from the center line of the joint. Remove the cable jacket of Cable 1 to 37" (940mm) and Cable 2 to 21" (530mm). Fold back the shield wires. Cut both cables at the center line of the joint.
- Prepare Cable 1 and Store Housing
Taper the edge of Cable 1 insulation shield by 1/2" to 1-1/2" (13mm to 38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the housing onto Cable 1 up to the shield wires.
- Prepare Cables for Splice Installation
Carefully remove the cable insulation and then the insulation shield from both cables. Ensure not to cut or nick the cable insulation or conductor. For 500-750 MCM cables, the conductor length should be 2 1/2" (64mm) and the insulation shield length 6 1/4" (159mm). For 1000 MCM cables, the conductor length should be 2 3/8" (68mm) and the insulation shield length 6 3/8" (162mm).
- Install Splice
If conductors are aluminum, wire-brush them and immediately insert into the splice. Crimp the splice following the manufacturer's recommendations. Wipe off excess inhibitor. Check the distance between cable insulations; if it exceeds the Max Check After dimension, redo the assembly. Remove any sharp protrusions or burrs from the splice. Clean the cables where indicated and lubricate in the direction of the arrows to create a ramp of lubricant at the edge of the insulation shield.
- Complete Joint Assembly
Slide the housing into its final position, ensuring proper alignment by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV ONLY: Install two DELTECt Cable ties on each end of the cable entrance, approximately 1/4" from the edge of the splice and then 1/4" from the first tie with an offset of the locking heads. Use the T&B WT3D tool to tighten and trim the ties. Remove the yellow pin from the joint grounding eye. Retrain shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket over both cables and the joint housing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.