ABB - Installation Products 25PCJ1H1270 - 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

ABB Installation Products 25PCJ1H1270 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786970261


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 25kV Power Cable Joint Style 1 (SKU: 25PCJ1H1270) is a single-piece housing joint designed for reliable 25kV power cable termination in utility, industrial, and commercial applications. This joint accommodates cable insulation diameters from 0.850 inches to 1.050 inches, ensuring compatibility with a wide range of medium-voltage cables. It supports both stranded 4/0 AWG and solid 250 AWG aluminum conductors, providing flexibility for diverse installation requirements. The Style 1 design simplifies installation with a single-piece housing that reduces assembly time and minimizes potential failure points. The joint maintains the integrity of the cable's insulation and electrical performance, ensuring long-term reliability in critical power distribution networks. Its robust construction prioritizes safety and longevity, making it suitable for high-voltage applications where uninterrupted power flow is essential. Key specifications include a 25 kV voltage rating, aluminum conductor compatibility, and dimensional compatibility with insulation diameters between 0.850 and 1.050 inches. The joint is part of ABB's Installation Products line, known for quality and adherence to industry standards. It is ideal for terminating medium-voltage power cables in substations, switchgear, and other high-voltage distribution systems. The product includes a power cable joint housing (25PCJ1-W), connector (02403XXX), lubricant tube (82-08), installation instructions (IS-0332, IS-0179, IS-0180, or IS-0182), and a crimp chart (CC-0038, CC-0039, or CC-0042). The joint is designed for ease of use, with clear dimensional data and conductor size compatibility provided in the catalog for accurate selection.
  • Single-piece housing for simplified installation and reduced failure points
  • Supports 25 kV voltage rating with aluminum conductor compatibility
  • Accommodates cable insulation diameters from 0.850 to 1.050 inches
  • Compatible with stranded 4/0 AWG and solid 250 AWG aluminum conductors
  • Includes housing, connector, lubricant, and installation instructions

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
4/0 STR AWG , 250 kcmil
Connection
Compression
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Series
25PCJ1
Size
14-3/8 inch long
Size
Cable Insulation Diameter 0.850 inch to 1.050 inch, Conductor Size AWG Stranded 4/0 /Solid 250
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

25PCJ1J2270

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

35PCJ1L2270

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.

25PCJ2L1300

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 750.

15PCJ2L2360

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 750.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 500. Length 21.0 inch x 3.75 inch Diameter.

15PCJ2-M2360-L2310

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 500. Length 21.0 inch x 3.75 inch Diameter.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Metallic Tape Shield Adapter. Replacement part is 600ECS-G3.

25PCJ1N1410-0MA

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Metallic Tape Shield Adapter. Replacement part is 600ECS-G3.
15kv Power Cable Joint, Style 2, Insulation Diameter .640 inch to .820 inch, Aluminum Conductor, Conductor Size 230 - Stranded/Compressed #1, Compact/Solid 1/0.

15PCJ2F1230

15kv Power Cable Joint, Style 2, Insulation Diameter .640 inch to .820 inch, Aluminum Conductor, Conductor Size 230 - Stranded/Compressed #1, Compact/Solid 1/0.
25kV Power Cable Joint/Splice, Universal Housing and Separate Cable Adapters. Side 1 - Cable Insulation Diameter 1.370 to 1.630 inches, Copper Compression Lug, Conductor Size Stranded/Compressed 250. Side 2 - Cable Insulation Diameter .980 to 1.180 inches, Aluminum Compression Lug, Conductor Size Stranded/Compressed 4/0. Solid/Compact 250

25PCJ2M2280-J1270

25kV Power Cable Joint/Splice, Universal Housing and Separate Cable Adapters. Side 1 - Cable Insulation Diameter 1.370 to 1.630 inches, Copper Compression Lug, Conductor Size Stranded/Compressed 250. Side 2 - Cable Insulation Diameter .980 to 1.180 inches, Aluminum Compression Lug, Conductor Size Stranded/Compressed 4/0. Solid/Compact 250

Frequently Asked Questions

What is the voltage rating for this ABB cable joint?

This ABB power cable joint is rated for 25kV applications.

What cable insulation diameters does this joint accommodate?

The joint is designed to fit cable insulation diameters ranging from 0.850 inches to 1.050 inches.

What conductor types and sizes are compatible with this joint?

This joint is compatible with aluminum conductors, specifically 4/0 AWG stranded and 250 AWG solid.

What is the housing style of this ABB cable joint?

This ABB power cable joint features a single-piece housing, Style 1.

How to Install the 15/25/35PCJ1 Series Straight Joint

This guide provides step-by-step instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ1 series straight joint for wire shielded cables. It covers cable preparation, splice installation, and final assembly.

Estimated time: 2h

Tools needed:

Cable cutting tool, Cable jacket removal tool, Wire strippers, Wire brush, Crimping tool, Deburring tool, Measuring tape or ruler, T&B WT3D tool (for 35kV only)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Appropriate connector (for grounding wires), DELTECt Cable ties (TYD5135, for 35kV only), #14 AWG copper wire or equivalent (if needed), Cleaning supplies

  1. Ensure Safety and Inspect Components

    Before beginning, ensure all apparatus are de-energized. This product must be installed only by competent personnel trained in high voltage safety practices. Inspect all package contents for completeness and damage. Verify all components, including the joint housing, splice, and lubricant, are compatible with the cable and mating products.

  2. Prepare Cables for Joint Installation

    Overlap both cables and cut them to 12 inches (305mm) from the center line of the joint. Remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Finally, cut both cables precisely at the center line of the joint.

  3. Prepare Cable 1 and Position Joint Housing

    Taper the edge of Cable 1's insulation shield from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Carefully slide the joint housing onto Cable 1, positioning it up to the shield wires.

  4. Prepare Cables for Splice Connection

    Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2 according to the 'X' and 'Y' dimensions provided in the documentation for your specific conductor size (e.g., 500-750 MCM or 1000 MCM). Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor.

  5. Install and Crimp the Conductor Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Check the dimension against the 'Max Check Before' table; if it exceeds, redo the assembly. Crimp the splice following its specific recommendations. Wipe off any excess inhibitor. Verify the distance between cable insulations against the 'Max Check After' table; if it exceeds, redo the assembly. Remove any sharp protrusions or burrs from the crimping process and ensure the splice and joint assembly area are free of metal chips/filings.

  6. Lubricate and Finalize Splice Area

    Clean the cables where indicated around the splice. Lubricate the cables in the direction of the arrows shown in the documentation to create a build-up or ramp of lubricant at the edge of the insulation shield. This ensures proper sealing and insulation.

  7. Complete Joint Housing Assembly

    Slide the joint housing into its final position over the splice. Ensure proper positioning by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV installations ONLY, install two DELTECt Cable ties (TYD5135) on each end of the cable entrance, approximately 1/4 inch apart with offset locking heads, using a T&B WT3D tool. Remove and discard the yellow pin from the joint grounding eye.

  8. Connect Grounding and Shield Wires

    Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector.

  9. Reconstruct Cable Jacket

    Where applicable, reconstruct the cable jacket over both cables and the joint housing to complete the installation and provide environmental protection.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.