Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ2L2360 - 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 750.

ABB Installation Products 15PCJ2L2360 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable…

UPC: 783786976140


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 15kV Power Cable Joint, SKU 15PCJ2L2360, is designed for reliable splicing of medium-voltage power cables in electrical distribution and transmission systems. It features a Style 2 joint configuration with a universal housing, ensuring compatibility with a broad range of cable insulation diameters from 1.180 inches to 1.465 inches. The kit includes separate cable adapters specifically engineered for precise fitting to copper conductors sized at AWG Solid 750, providing a secure and insulated connection critical for maintaining system integrity and safety. The universal housing design simplifies inventory management and streamlines installation by accommodating multiple cable sizes within the specified range, reducing the need for specialized components. The separate adapters allow for tailored fitting, enhancing the joint’s performance and longevity in demanding applications. Proper installation is essential to prevent power loss, electrical faults, and operational disruptions, making this joint a dependable solution for high-voltage cable connections. The ABB Installation Products brand is recognized for delivering robust electrical infrastructure components, ensuring long-term reliability and compliance with industry standards. UNSPSC Code: 39121452.
  • 15kV rated power cable joint
  • Style 2 joint configuration
  • Universal housing for flexibility
  • Separate cable adapters included
  • Accommodates cable insulation diameter: 1.180" - 1.465"
  • Designed for AWG Solid 750 copper conductors

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
750 kcmil
Connection
Compression
Insulation
Yes
Material
Copper
Material
EPDM Rubber
Number Of Conductors
2
Size
21 inch long
Size
1.180 inch to 1.465 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 750.

15PCJ2N2410-L2360

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 750.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 500. Length 21.0 inch x 3.75 inch Diameter.

15PCJ2-M2360-L2310

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 500. Length 21.0 inch x 3.75 inch Diameter.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Metallic Tape Shield Adapter. Replacement part is 600ECS-G3.

25PCJ1N1410-0MA

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Metallic Tape Shield Adapter. Replacement part is 600ECS-G3.
15kv Power Cable Joint, Style 2, Insulation Diameter .640 inch to .820 inch, Aluminum Conductor, Conductor Size 230 - Stranded/Compressed #1, Compact/Solid 1/0.

15PCJ2F1230

15kv Power Cable Joint, Style 2, Insulation Diameter .640 inch to .820 inch, Aluminum Conductor, Conductor Size 230 - Stranded/Compressed #1, Compact/Solid 1/0.
25kV Power Cable Joint/Splice, Universal Housing and Separate Cable Adapters. Side 1 - Cable Insulation Diameter 1.370 to 1.630 inches, Copper Compression Lug, Conductor Size Stranded/Compressed 250. Side 2 - Cable Insulation Diameter .980 to 1.180 inches, Aluminum Compression Lug, Conductor Size Stranded/Compressed 4/0. Solid/Compact 250

25PCJ2M2280-J1270

25kV Power Cable Joint/Splice, Universal Housing and Separate Cable Adapters. Side 1 - Cable Insulation Diameter 1.370 to 1.630 inches, Copper Compression Lug, Conductor Size Stranded/Compressed 250. Side 2 - Cable Insulation Diameter .980 to 1.180 inches, Aluminum Compression Lug, Conductor Size Stranded/Compressed 4/0. Solid/Compact 250
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. J- Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. 330-Conductor Size Stranded 500. H- Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. 270-Conductor Size Stranded 4/0 or 250 Solid/Compact. S- Cold Shrinkable Jacket Seal.

15PCJ2J1330H1270-S

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. J- Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. 330-Conductor Size Stranded 500. H- Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. 270-Conductor Size Stranded 4/0 or 250 Solid/Compact. S- Cold Shrinkable Jacket Seal.
15kV, Power Cable Joint Splice with Sealing Kit, Single Piece Housing, Cable Insulation Diameter J - .980 -1.050 inches. Copper Conductor, Conductor Size - 500 Stranded/Compressed. Includes Cold Shrinkable Jacket Seal.

15PCJ1J2330-S

15kV, Power Cable Joint Splice with Sealing Kit, Single Piece Housing, Cable Insulation Diameter J - .980 -1.050 inches. Copper Conductor, Conductor Size - 500 Stranded/Compressed. Includes Cold Shrinkable Jacket Seal.
15kV, Power Cable Joint with Single Piece Housing. Copper Conductor. Cable Insulation Diameter Range 1.515 to 1.780 inch, Conductor Size 1250 Compressed/Stranded. No Sealing Kit.

15PCJ1-N2440

15kV, Power Cable Joint with Single Piece Housing. Copper Conductor. Cable Insulation Diameter Range 1.515 to 1.780 inch, Conductor Size 1250 Compressed/Stranded. No Sealing Kit.

Frequently Asked Questions

What types of cables can PCJ joints splice?

PCJ power cable joints can splice two similar cables (straight splicing) or different cable sizes (transition splicing) up to 1250 kcmil. They work with copper or aluminum conductors.

What is the continuous current rating of PCJ joints?

The continuous current rating of PCJ power cable joints is equal to that of the cable rating.

What is the purpose of the grounding eye?

The grounding eye provides a convenient point to connect a ground wire to the molded conductive shield, placing the molded shield at ground potential.

What pull force can the pin-and-socket interlock withstand?

The pin-and-socket interlock of the PCJ power cable joint can withstand a pull force up to 500 lb.

Can copper connectors be used with aluminum conductors?

No, copper compression connectors are suitable for splicing copper conductors to copper conductors only. Do not use copper connectors on aluminum conductors.

What is the short-time current rating of PCJ joints?

The short-time current rating of PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What standards do PCJ joint shields and connectors meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

What is the difference between PCJ Style 1 and Style 2?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

What is the maximum conductor size for PCJ joints?

PCJ power cable joints can be used with conductors up to 1250 kcmil, for both copper and aluminum.

What environments are suitable for PCJ joint installation?

PCJ power cable joints provide a permanent, fully shielded, fully submersible splice suitable for direct-burial, underground vault, and overhead applications.

How to Install the 15PCJ2L2360 Straight Joint

This guide provides step-by-step instructions for the permanent, fully shielded, and submersible installation of the 15PCJ2L2360 straight joint for aluminum and/or copper conductor, wire shielded cables.

Estimated time: 1h 30m

Tools needed:

Stripping guide, Circular cutting tool or glass (for graphite removal), Hex wrench, Wirebrush, Crimping tool, Appropriate connector (user supplied)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Cable Adapters, Lubricant, 2 Retaining Collars, Hose Clamp, Electrical Tape, No. 14 AWG copper wire or equivalent (if needed), Heat/cold shrink kit (for cable jacket reconstruction, not included)

  1. Observe Safety Precautions and Perform Initial Checks

    DANGER: Ensure all apparatus is de-energized during installation or removal. This product must be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Failure to follow instructions will result in damage and serious injury. Inspect all parts for damage, rating, and compatibility. Check package contents for completeness. Examine mating cable ends for moisture and contaminants. Remove graphite coatings 12 inches (30.5cm) beyond the cable jacket cut, avoiding sanding.

  2. Prepare Cables and Install Joint Housing

    Using the stripping guide, carefully remove the cable jacket of both cables for a distance of 11-1/4 inches (285.7mm). Fold back shield wires and tape the end of wires on Cable 1 to the jacket, allowing enough extra length to rejoin later. Clean the surface of the insulation shield, shield wires, and jacket for a distance of 30 inches (760mm). Slide the joint housing onto Cable 1 to a distance of 30 inches (760mm). Next, remove the insulation shield and cable insulation, ensuring you DO NOT CUT OR NICK THE INSULATION, as this could lead to assembly failure. Wrap two turns of tape 1 inch (25mm) from the edge of the insulation shield as a marker on both cables. Clean the cable insulation, then lubricate it to create a build-up or ramp of lubricant at the edge of the insulation shield.

  3. Install Cable Adapters and Retaining Collars

    Take one cable adapter and lubricate the inside of both ends. Install the cable adapter onto the cable until it meets the tape marker. Repeat this process for the other cable adapter on the second cable. Select the appropriate retaining collar and partially thread the setscrews into it. Position the retaining collar over the insulation and flush against the cable adapter. Using the supplied hex wrench, tighten each set screw only one or two turns at a time to keep the collar centered over the insulation. Continue tightening the set screws until they are below the surface of the collar. Repeat this procedure for Cable 2.

  4. Install and Crimp the Splice

    Thoroughly clean the ends of the cable adapters and the cable where shown. Install a hose clamp around the adapter on the opposite side of the splice from where the housing is stored to hold the adapter in place during final assembly. Tape over the hose clamp to form a smooth surface. Wirebrush the exposed conductors of both cables and immediately insert them into the splice. Ensure the 'Check' dimension does not exceed 8-1/2 inches (215mm); if it does, redo the assembly. Crimp the splice following the recommendations provided with it. Wipe off all excess inhibitor, then check the distance between the cable adapters. If it exceeds 8-3/4 inches (222mm), redo the assembly. Clean and lubricate the outside surface of the cable adapters before sliding the housing into its final position.

  5. Complete Joint Assembly and Grounding

    Slide the joint housing into its final position, centering it over the cable adapters. Remove all tape, ensuring that cable and adapter insulation are not exposed after positioning the joint. Reshape the shield wires and secure them to the ends of the joint as shown. Insert one of the shield wires from Cable 1 (if #14 AWG or larger) through the joint grounding eye. Repeat this for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket (where applicable) over both cables and also over the joint housing, using a heat or cold shrink kit (not included).

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.