ABB Installation Products 35PCJ1L2270 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786971374
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV Voltage Rating
- Single-piece housing for simplified installation
- Accommodates cable insulation diameters from 1.180" to 1.465"
- Designed for copper conductors (AWG Stranded 4/0 / Solid 250)
- ABB Installation Products quality
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 4/0 STR AWG , 250 kcmil |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Size | 14-3/8 inch long |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

35PCJ1K2270
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
25PCJ2L1300
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.
15PCJ2L2360
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 750.
15PCJ2-M2360-L2310
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 500. Length 21.0 inch x 3.75 inch Diameter.
25PCJ1N1410-0MA
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Metallic Tape Shield Adapter. Replacement part is 600ECS-G3.
15PCJ2F1230
15kv Power Cable Joint, Style 2, Insulation Diameter .640 inch to .820 inch, Aluminum Conductor, Conductor Size 230 - Stranded/Compressed #1, Compact/Solid 1/0.
25PCJ2M2280-J1270
25kV Power Cable Joint/Splice, Universal Housing and Separate Cable Adapters. Side 1 - Cable Insulation Diameter 1.370 to 1.630 inches, Copper Compression Lug, Conductor Size Stranded/Compressed 250. Side 2 - Cable Insulation Diameter .980 to 1.180 inches, Aluminum Compression Lug, Conductor Size Stranded/Compressed 4/0. Solid/Compact 250
15PCJ2J1330H1270-S
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. J- Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. 330-Conductor Size Stranded 500. H- Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. 270-Conductor Size Stranded 4/0 or 250 Solid/Compact. S- Cold Shrinkable Jacket Seal.Frequently Asked Questions
What types of cable splicing do PCJ joints support?
PCJ power cable joints support straight splicing of two similar cables or transition splicing of different cable sizes.
What safety standards do PCJ joints meet?
The shield design meets IEEE 592 standard, and connectors meet ANSI 119.4 Class A and Class 3 ratings.
When should an aluminum compression connector be used?
An aluminum compression connector is suitable for splicing aluminum to aluminum or aluminum to copper conductors.
What is the BIL impulse withstand for a 35 kV class joint?
For a 35 kV class joint, the BIL impulse withstand is 300 kV (1.2 x 50 μsec. wave).
What is the short-time current rating?
The short-time current rating of PCJ power cable joints is equal to that of the cable rating, up to 35 kA.
What is the continuous current rating?
The continuous current rating of PCJ power cable joints is equal to that of the cable rating.
What pull force can the interlock withstand?
The pin-and-socket interlock in PCJ joints can withstand a pull force of up to 500 lb.
What are the two styles of PCJ cable joints?
Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.
What conductor materials and sizes are compatible?
PCJ power cable joints can be used with copper or aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.
What voltage classes are PCJ cable joints available in?
PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
How to Install the 35PCJ1L2270 Cable Joint
This guide provides step-by-step instructions for installing the 35PCJ1L2270 permanent, fully shielded, and submersible cable joint. It covers cable preparation, splice installation, and final assembly for high-voltage electrical systems.
Estimated time: 2h
Tools needed:
Wire strippers, Utility knife, Wire-brush (for aluminum conductors), Crimping tool, T&B WT3D tool (for 35kV only, for Deltect ties)
Supplies needed:
Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Connector (user supplied, for grounding wires), Deltect Cable ties (TYD5135, for 35kV only), #14 AWG Copper wire or equivalent (if shield wires are small), Cleaning supplies
- Prepare Cables and Ensure Safety
De-energize all apparatus in the work area before beginning installation. Overlap both cables and cut them to 12 inches (305mm) from the center line of the joint. Remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm) where applicable. Fold back the shield wires and then cut both cables at the joint's center line.
- Prepare Cable 1 and Temporarily Store Housing
Taper the edge of Cable 1's insulation shield from 1/2 inch (13mm) to 1-1/2 inches (38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Slide the housing onto Cable 1, pushing it up to the shield wires for temporary storage.
- Prepare Cables for Splice Installation
Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2 according to the specified dimensions for conductor 'X' and 'Y' based on MCM size. Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor during this process.
- Install and Crimp the Splice
If conductors are aluminum, wire-brush them and immediately insert into the splice. Verify the dimension against the 'Max Check Before' table; if it exceeds, redo assembly. Crimp the splice per recommendations. Wipe off excess inhibitor. Check distance between cable insulations against 'Max Check After' table; if it exceeds, redo assembly. Remove sharp protrusions/burrs and metal chips. Clean cables where indicated and lubricate to create a build-up at the insulation shield edge.
- Complete Joint Assembly and Grounding
Slide the joint housing into its final position, equalizing deformation of joint ends. For 35kV only, install two DELTEC Cable ties on each end of the cable entrance (1/4 inch from splice edge, 1/4 inch from first tie with offset heads) using a T&B WT3D tool. Remove and discard the yellow pin from the joint grounding eye. Retrain shield wires and secure to joint ends. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, repeat for Cable 2. If smaller, use #14 AWG copper wire. Connect grounding wires and remaining shield wires using an appropriate connector. Reconstruct cable jacket over both cables and joint housing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.