ABB Installation Products 25PCJ1L2330 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786652662
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25kV voltage rating for medium-voltage applications
- Style 1 single-piece housing for simplified installation
- Accommodates cable insulation diameters from 1.180" to 1.465"
- Designed for 500 AWG stranded copper conductors
- Reliable termination from ABB Installation Products
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 500 kcmil |
Connection | Compression |
Insulation | Yes |
Material | Copper |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Series | Style 1 |
Size | 14-3/8 inch long |
Size | Cable Insulation Diameter 1.180 inch to 1.465 inch |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.2500 L |
Package Weight (Metric) | 1.4740 kg |

25PCJ1M2330
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 500.
25PCJ1H1230
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
35PCJ1J1230
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
25PCJ1J1270
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
25PCJ1L1330
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
15PCJ2J1270-H1270
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
25PCJ1G1240
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15PCJ2M1380-K1330
15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, End #1 Insulation Diameter 1.370-1.630 inches, Aluminum Conductor, Conductor Size 750 Stranded/Compressed. End #2 Insulation Diameter 1.090-1.310 inches, Aluminum Conductor, Conductor Size 500 Stranded/Compressed.Frequently Asked Questions
What is the insulation diameter range for this cable joint?
This ABB 25kV power cable joint is designed to accommodate cable insulation diameters ranging from 1.180 inches to 1.465 inches.
What conductor size and type is this joint designed for?
This joint is specifically designed for 500 AWG stranded copper conductors.
What is the voltage rating of this ABB cable joint?
The ABB 25kV Power Cable Joint has a voltage rating of 25kV.
What style of housing does this cable joint feature?
This cable joint features a Style 1 single-piece housing.
How to Install the 15/25/35PCJ1 Series Cable Joint
This guide provides step-by-step instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ1 series straight joint for wire shielded cables, connecting aluminum to aluminum and/or aluminum to copper conductors.
Estimated time: 2h
Tools needed:
Wire strippers, Cable cutting tool, Measuring tape or ruler, Wire brush (for aluminum conductors), Crimping tool, T&B WT3D tool (recommended for 35kV DELTEC Cable ties)
Supplies needed:
Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Appropriate connector (user supplied), DELTEC Cable ties (TYD5135, for 35kV ONLY), #14 AWG copper wire or equivalent (if shield wires are smaller than #14 AWG)
- Ensure Safety and Verify Components
Before beginning, ensure all apparatus is de-energized. Do not touch or move energized products in the work area. Verify the package contents are complete and undamaged, and all components fit properly with the cable and mating products. Read all instructions thoroughly and have all required tools ready, maintaining cleanliness throughout the procedure. Failure to follow these instructions will result in damage to the product and serious or fatal injury.
- Prepare Cables for Joint Centerline
Overlap both cables and cut them to 12 inches (305mm) from the center line of the joint to ensure sufficient length of shield wires. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires, then cut both cables precisely at the joint's center line.
- Prepare Cable 1 and Position Joint Housing
Taper the edge of Cable 1 from at least 1/2 inch to no greater than 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Carefully slide the housing onto Cable 1, positioning it up to the shield wires.
- Prepare Cables for Splice
Carefully remove the cable insulation from both Cable 1 and Cable 2. Subsequently, carefully remove the insulation shield from both cables. Exercise extreme caution to avoid cutting or nicking the cable insulation or the conductor during this process.
- Install and Crimp the Conductor Splice
If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Check the dimension against the provided table (e.g., 6 inches for 500-750 MCM) and redo assembly if it exceeds the "Max Check Before" dimension. Crimp the splice according to its specific recommendations. Wipe off any excess inhibitor. After crimping, check the distance between cable insulations against the "Max Check After" dimension (e.g., 6 1/4 inches for 500-750 MCM) and redo if exceeded. Remove any sharp protrusions or burrs generated during crimping and ensure all metal chips/filings are cleared from the splice and joint assembly area. Clean and lubricate the cables where indicated, building up a ramp of lubricant at the edge of the insulation shield.
- Complete Joint Assembly and Grounding Connections
Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV installations ONLY, install two DELTEC Cable ties on each end of the cable entrance, approximately 1/4 inch from the splice edge, with the second tie 1/4 inch from the first and offset locking heads; use the T&B WT3D tool for tightening. Remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.