Authorized ABB Distributor (Installation Products)
ABB - Installation Products 25PCJ1H1230 - 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
More images

ABB Installation Products 25PCJ1H1230 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786656400


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Installation Products 25PCJ1H1230 is a 25kV Power Cable Joint Style 1 designed for reliable medium-voltage cable splicing in industrial and utility applications. This joint accommodates cable insulation diameters from 0.850 inch to 1.050 inch, making it suitable for #1 AWG stranded or solid 1/0 AWG aluminum conductors. The single-piece housing simplifies installation while ensuring consistent performance in power distribution systems. This joint is rated for 25kV operation, providing a secure connection for medium-voltage circuits in substations, industrial plants, and renewable energy installations. The aluminum construction offers lightweight durability and corrosion resistance, reducing long-term maintenance requirements. The Style 1 design is optimized for compatibility with standard medium-voltage cable constructions, ensuring proper insulation and mechanical protection. Key applications include: - Utility power distribution networks - Industrial facility wiring - Renewable energy interconnections - Commercial building electrical systems The 25PCJ1H1230 is part of ABB’s Installation Products line, known for reliable electrical components in demanding environments. For projects requiring medium-voltage cable joints with proven performance and simplified installation, this product delivers consistent results.
  • Voltage rating: 25kV for medium-voltage applications
  • Insulation diameter range: 0.850 inch to 1.050 inch
  • Conductor compatibility: #1 AWG stranded or solid 1/0 AWG aluminum
  • Single-piece housing for simplified installation
  • Part of ABB Installation Products line for reliable performance

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
#1 STR AWG , 1/0 SOL AWG
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.6600 L
Package Weight (Metric)
0.7530 kg
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

25PCJ1H2230

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

35PCJ1J1230

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

25PCJ1J1270

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

25PCJ1L1330

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ2J1270-H1270

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

25PCJ1G1240

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, End #1 Insulation Diameter 1.370-1.630 inches, Aluminum Conductor, Conductor Size 750 Stranded/Compressed. End #2 Insulation Diameter 1.090-1.310 inches, Aluminum Conductor, Conductor Size 500 Stranded/Compressed.

15PCJ2M1380-K1330

15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, End #1 Insulation Diameter 1.370-1.630 inches, Aluminum Conductor, Conductor Size 750 Stranded/Compressed. End #2 Insulation Diameter 1.090-1.310 inches, Aluminum Conductor, Conductor Size 500 Stranded/Compressed.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

15PCJ2M1380-L1330

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

Frequently Asked Questions

What type of connector is included for aluminum conductors?

The kit includes an aluminum compression connector suitable for splicing aluminum conductor to aluminum conductor or aluminum conductor to copper conductor.

Can copper connectors be used with aluminum conductors?

No, copper compression connectors are suitable for copper-to-copper connections only. Do not use copper connectors on aluminum conductors.

Can copper connectors be used with aluminum conductors?

No, copper compression connectors are suitable for copper-to-copper connections only. Do not use copper connectors on aluminum conductors.

What type of connector is included for aluminum conductors?

The kit includes an aluminum compression connector suitable for splicing aluminum conductor to aluminum conductor or aluminum conductor to copper conductor.

Can copper connectors be used with aluminum conductors?

No, copper compression connectors are suitable for copper-to-copper connections only. Do not use copper connectors on aluminum conductors.

What type of connector is included for aluminum conductors?

The kit includes an aluminum compression connector suitable for splicing aluminum conductor to aluminum conductor or aluminum conductor to copper conductor.

What type of connector is included for aluminum conductors?

The kit includes an aluminum compression connector suitable for splicing aluminum conductor to aluminum conductor or aluminum conductor to copper conductor.

Can copper connectors be used with aluminum conductors?

No, copper compression connectors are suitable for copper-to-copper connections only. Do not use copper connectors on aluminum conductors.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 uses separate cable adapters for transition splicing between different cable sizes.

How to Install the 15/25/35PCJ1 Straight Joint

This guide provides detailed instructions for installing the 15/25/35PCJ1 straight joint, a permanent, fully shielded, and submersible solution for connecting high-voltage cables with aluminum or copper conductors.

Estimated time: 2h

Tools needed:

Cable cutting tool, Wire strippers, Wire-brush (for aluminum conductors), Crimping tool, Measuring tape or ruler, T&B WT3D tool (recommended for 35kV installations)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Connector (user supplied, for grounding wires), DELTECt Cable ties (TYD5135, for 35kV ONLY), #14 AWG copper wire or equivalent (if existing shield wires are smaller than #14 AWG)

  1. De-energize and Prepare Work Area

    DANGER: Ensure all apparatus is de-energized before beginning installation. Do not touch or move energized products. This product must be installed by competent personnel trained in high-voltage safety practices. Inspect all package contents and components for damage, proper rating, and compatibility with mating parts. Have all required tools at hand and maintain cleanliness throughout the procedure.

  2. Initial Cable Preparation

    Overlap both cables and cut them to 12 inches (305mm) from the center line of the joint to ensure sufficient length for shield wires. Remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires on both cables. Finally, cut both cables at the designated center line of the joint.

  3. Taper Cable 1 and Position Joint Housing

    Taper the edge of Cable 1's insulation shield at least 1/2 inch (13mm) to no more than 1-1/2 inches (38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Carefully slide the joint housing onto Cable 1, pushing it up to the shield wires.

  4. Remove Cable Insulation and Shield

    Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2 according to the dimensions specified for your conductor size (refer to the 'X' and 'Y' dimensions in the document). WARNING: DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR during this process.

  5. Install and Crimp Conductor Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Verify the dimension against the 'Max Check Before' table for your conductor size; if it exceeds the maximum, redo the assembly. Crimp the splice following the recommendations provided with it. After crimping, wipe off any excess inhibitor and check the distance between cable insulations against the 'Max Check After' table; redo assembly if it exceeds the maximum. Remove any sharp protrusions or burrs generated during crimping and ensure all metal chips/filings are removed from the splice and joint assembly area.

  6. Clean and Lubricate Cables for Housing

    Clean the cables where indicated in the diagram. Lubricate the cables in the direction of the arrows to create a build-up or ramp of lubricant at the edge of the insulation shield. This prepares the surface for the final housing placement.

  7. Finalize Joint Housing and Grounding Connections

    Slide the joint housing into its final position. Ensure proper positioning by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV installations ONLY: Install two DELTECt Cable ties on each end of the cable entrance, approximately 1/4 inch (6mm) from the edge of the splice and 1/4 inch (6mm) from the first, with an offset of the locking heads. Use the T&B WT3D tool to tighten and trim the ties. Also, remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint as shown in the diagram. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate user-supplied connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.