Authorized ABB Distributor (Installation Products)
ABB - Installation Products 35PCJ1J1230 - 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

ABB Installation Products 35PCJ1J1230 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786659753


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 35kV Power Cable Joint, SKU 35PCJ1J1230, is designed for reliable termination of medium voltage power cables. It features a single-piece housing for straightforward installation and is engineered to accommodate cable insulation diameters ranging from 0.980 inches to 1.180 inches. This joint is suitable for aluminum conductors, specifically for stranded AWG #1 or solid AWG 1/0 conductor sizes. The UNSPSC code 39121452 indicates its classification within electrical power distribution equipment. This product ensures a secure and insulated connection for power distribution networks. Its construction is focused on providing a durable and effective joint for 35kV applications. The specified insulation diameter range allows for compatibility with a defined set of cable constructions, ensuring a proper seal and electrical integrity. The use of aluminum conductors is a common specification in many power infrastructure projects. The ABB brand signifies a commitment to quality in electrical installation products. This joint is a key component for maintaining the continuity and safety of medium voltage power transmission systems. Its design prioritizes ease of application while meeting the electrical requirements for 35kV systems.
  • 35kV rated power cable joint
  • Single-piece housing for simplified installation
  • Accommodates cable insulation diameters from 0.980" to 1.180"
  • Designed for aluminum conductors: AWG Stranded #1 or Solid 1/0
  • Manufacturer: ABB - Installation Products

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
#1 STR AWG , 1/0 SOL AWG
Connection
Compression
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Series
Style 1
Size
14-3/8 inch long
Size
0.980 inch to 1.180 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.7500 L
Package Weight (Metric)
0.7940 kg
35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

35PCJ2J1230

35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

25PCJ1J1270

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

25PCJ1L1330

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ2J1270-H1270

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

25PCJ1G1240

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, End #1 Insulation Diameter 1.370-1.630 inches, Aluminum Conductor, Conductor Size 750 Stranded/Compressed. End #2 Insulation Diameter 1.090-1.310 inches, Aluminum Conductor, Conductor Size 500 Stranded/Compressed.

15PCJ2M1380-K1330

15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, End #1 Insulation Diameter 1.370-1.630 inches, Aluminum Conductor, Conductor Size 750 Stranded/Compressed. End #2 Insulation Diameter 1.090-1.310 inches, Aluminum Conductor, Conductor Size 500 Stranded/Compressed.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

15PCJ2M1380-L1330

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 250.

15PCJ1J1280

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 250.

Frequently Asked Questions

Can copper connectors be used with aluminum conductors?

No, copper compression connectors included in the kit are suitable for copper-to-copper connections only and should not be used on aluminum conductors.

What is the short-time current rating of PCJ joints?

The short-time current rating of PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What is the continuous current rating of PCJ joints?

The continuous current rating of PCJ power cable joints is equal to that of the cable rating.

What safety standards do PCJ joints meet?

The shield design of PCJ power cable joints meets the IEEE 592 standard. The connectors meet ANSI 119.4 Class A and Class 3 ratings.

What conductor types are compatible with PCJ joints?

PCJ power cable joints are compatible with copper or aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What is the continuous current rating of PCJ joints?

The continuous current rating of PCJ power cable joints is equal to that of the cable rating.

What is the short-time current rating of PCJ joints?

The short-time current rating of PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

Can copper connectors be used with aluminum conductors?

No, copper compression connectors included in the kit are suitable for copper-to-copper connections only and should not be used on aluminum conductors.

What safety standards do PCJ joints meet?

The shield design of PCJ power cable joints meets the IEEE 592 standard. The connectors meet ANSI 119.4 Class A and Class 3 ratings.

How to Install the 35PCJ1J1230 Straight Joint

This guide provides detailed instructions for the permanent installation of the 35PCJ1J1230 straight joint, designed for wire shielded cables with aluminum or copper conductors, ensuring a fully shielded and submersible connection.

Estimated time: 2h

Tools needed:

Wire strippers, Utility knife, Wire brush, Crimping tool, T&B WT3D tool (for 35kV only)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), User-supplied conductor connector, #14 AWG copper wire or equivalent, DELTECt Cable ties (TYD5135, for 35kV only), Appropriate grounding connector

  1. Prepare for Installation and Ensure Safety

    De-energize all apparatus in the work area before beginning installation. Inspect all parts for damage, correct rating, and compatibility with mating products. Check package contents for completeness and ensure proper fit with the cable. Gather all required tools and maintain cleanliness throughout the procedure. This product must be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment.

  2. Prepare Cables for Joint Assembly

    Overlap both cables and cut them to 12 inches (305mm) from the center line of the joint to ensure sufficient length of shield wires. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires on both cables. Cut both cables precisely at the center line of the joint.

  3. Prepare Cable 1 and Store Joint Housing

    Taper the edge of Cable 1 insulation from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the joint housing onto Cable 1, pushing it up to the shield wires for temporary storage.

  4. Prepare Cables for Splice and Remove Insulation

    Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2 according to the specified dimensions (e.g., for 500-750 MCM, remove 2 1/2 inches of insulation and 6 1/4 inches of shield). DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR during this process.

  5. Install and Crimp the Conductor Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Check the conductor dimension against the 'Max Check Before' table; if it exceeds the maximum, redo the assembly. Crimp the splice following the recommendations provided with the splice. Wipe off any excess inhibitor from the splice area. Check the distance between cable insulations against the 'Max Check After' table; if it exceeds the maximum, redo the assembly. Remove any sharp protrusions or burrs generated during crimping. Ensure all metal chips or filings are removed from the splice and joint assembly area. Clean the cables where indicated and lubricate in the direction of the arrows to create a build-up or ramp of lubricant at the edge of the insulation shield.

  6. Complete Joint Assembly and Grounding

    Slide the joint housing into its final position. Ensure proper positioning by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV ONLY: Install two DELTECt Cable ties on each end of the cable entrance. Position the outer ties approximately 1/4 inch (6mm) from the edge of the splice. Install the second ties approximately 1/4 inch (6mm) from the first, offsetting the locking heads. Use the T&B WT3D tool (recommended) to tighten and trim the cable ties. Remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint as shown in the diagrams. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye. Repeat this for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector. Reconstruct the cable jacket (where applicable) over both cables and the joint housing to complete the installation.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.