ABB - Installation Products 25PCJ1L1330 - 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

ABB Installation Products 25PCJ1L1330 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786661145


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 25kV Power Cable Joint Style 1 (SKU: 25PCJ1L1330) is a critical component for reliable power distribution systems. Designed for single-piece housing, this joint ensures a secure and insulated connection for aluminum conductors. It is specifically engineered to accommodate cable insulation diameters ranging from 1.180 inches to 1.465 inches. The joint is suitable for use with 500 AWG stranded aluminum conductors, a common size in medium-voltage applications. This product, manufactured by ABB - Installation Products, adheres to the UNSPSC code 39121452, indicating its classification within electrical power distribution and control components. Its robust construction and precise fit are essential for maintaining the integrity of high-voltage power cables, preventing electrical faults, and ensuring operational continuity in industrial and utility settings. The single-piece housing design simplifies installation while providing a durable seal against environmental factors. This joint is a key element in ensuring the safety and efficiency of electrical infrastructure. Its compatibility with specific conductor sizes and insulation diameters makes it a targeted solution for projects requiring dependable cable termination and splicing. The focus on material quality and design ensures long-term performance in demanding electrical environments.
  • 25kV voltage rating for medium-voltage applications
  • Single-piece housing for simplified installation
  • Accommodates cable insulation diameters from 1.180 to 1.465 inches
  • Designed for 500 AWG stranded aluminum conductors
  • Manufactured by ABB - Installation Products

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
500 kcmil
Connection
Compression
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Series
Power Cable Joint Style 1
Size
14-3/8 inch long
Size
1.180 inch to 1.465 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.7500 L
Package Weight (Metric)
0.7940 kg
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 500 kcmil.

25PCJ2K2330

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 500 kcmil.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ2J1270-H1270

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

25PCJ1G1240

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, End #1 Insulation Diameter 1.370-1.630 inches, Aluminum Conductor, Conductor Size 750 Stranded/Compressed. End #2 Insulation Diameter 1.090-1.310 inches, Aluminum Conductor, Conductor Size 500 Stranded/Compressed.

15PCJ2M1380-K1330

15kV, Power Cable Joint, Style 2 with Universal Housing and Separate Cable Adapters that can be varied with the Cable Application, End #1 Insulation Diameter 1.370-1.630 inches, Aluminum Conductor, Conductor Size 750 Stranded/Compressed. End #2 Insulation Diameter 1.090-1.310 inches, Aluminum Conductor, Conductor Size 500 Stranded/Compressed.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

15PCJ2M1380-L1330

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 250.

15PCJ1J1280

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ1G1260-1240

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ1G1250-1240

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

Frequently Asked Questions

Where can PCJ power cable joints be installed?

PCJ power cable joints can be installed in direct-burial, underground vault, and even overhead applications, providing a permanent, fully shielded, and submersible splice.

What is the continuous current rating of PCJ joints?

The continuous current rating of PCJ power cable joints is equal to that of the cable rating.

How do I order a transition joint for different cable sizes?

When constructing a catalog number for a transition joint, list the larger connector first and the smaller connector second.

Can copper connectors be used on aluminum conductors?

No, copper connectors should NOT be used on aluminum conductors. They are suitable for copper-to-copper connections only.

What connector types are included in PCJ kits?

Kits include aluminum compression connectors for aluminum-to-aluminum or aluminum-to-copper splicing. Copper compression connectors are for copper-to-copper connections only.

What electrical standard do PCJ power cable joints meet?

PCJ power cable joints meet IEEE 404, latest revision, for electrical ratings.

What is the short-time current rating of PCJ joints?

The short-time current rating of PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What safety standards do PCJ power cable joints meet?

The shield design meets IEEE 592 standard. The connectors meet ANSI 119.4 Class A and Class 3 ratings.

What pull force can the PCJ joint withstand?

The pin-and-socket interlock of the PCJ power cable joint is designed to withstand a pull force of up to 500 lb.

What types of cables are PCJ joints designed for?

PCJ joints are designed for UD cable with concentric neutral and extruded insulation shielding. They also work with fabric-tape shielded or lead-jacketed cables using proper adapters.

How to Install the 25PCJ1 Series Straight Joint

This guide provides detailed instructions for installing the 15/25/35PCJ1 Series straight joint, a permanent, fully shielded, and submersible joint for wire shielded cables. It covers cable preparation, splice installation, and final assembly for aluminum to aluminum or aluminum to copper conductors.

Estimated time: 2h

Tools needed:

Wire brush, Crimping tool (for splice and connectors), T&B WT3D tool (recommended for 35kV cable ties, if applicable), Cable stripping tools, Utility knife

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Appropriate connector (for grounding wires), DELTECt Cable ties (TYD5135, for 35kV only), No. 14 AWG copper wire (or equivalent, if shield wires are smaller)

  1. Ensure Safety and Prepare for Installation

    DANGER: All apparatus must be de-energized during installation. Do not touch or move energized products. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all parts for damage, rating, and compatibility with mating parts. Gather all required tools and supplies, and maintain cleanliness throughout the procedure.

  2. Prepare Cables for Joint Centerline

    Overlap both cables and cut them to 12 inches (305mm) from the intended centerline of the joint to ensure sufficient length of shield wires. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Finally, cut both cables at the joint centerline.

  3. Prepare Cable 1 and Store Housing

    Taper the edge of Cable 1's insulation shield at least 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Slide the housing onto Cable 1, positioning it up to the shield wires.

  4. Prepare Cables for Splice Installation

    Carefully remove the cable insulation and then the insulation shield from both cables. DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR during this process. Refer to the provided dimensions for 'X' and 'Y' based on your conductor size (e.g., 500-750 MCM or 1000 MCM).

  5. Install the Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Check the dimension against the 'Max Check Before' table; if it exceeds, redo the assembly. Crimp the splice following the manufacturer's recommendations. Wipe off any excess inhibitor. Check the distance between cable insulations against the 'Max Check After' table; if it exceeds, redo the assembly. Remove any sharp protrusions or burrs generated during crimping and ensure all metal chips/filings are removed from the splice and joint assembly area. Clean the cables where indicated and lubricate in the direction of the arrows to create a build-up or ramp of lubricant at the edge of the insulation shield.

  6. Complete Joint Assembly

    Slide the housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV ONLY: Install two DELTECt Cable ties on each end of the cable entrance, starting 1/4 inch (6mm) from the splice edge, then a second 1/4 inch (6mm) from the first with offset locking heads (T&B WT3D tool recommended). Remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2 (use separate #14 AWG copper wire if shield wires are smaller). Connect the joint grounding wires and remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.