Authorized ABB Distributor (Installation Products)
ABB - Installation Products 25PCJ2H2280 - 25 kV Power Cable Joint, Style 2 Universal Housing and Separate Cable Adapters. Cable Insulation Diameter H - .850 - 1.050 inch, Copper Conductor, Cable Size 280 - 250 kcmil Stranded/Compressed.

ABB Installation Products 25PCJ2H2280 25 kV Power Cable Joint, Style 2 Universal Housing and Separate Cable Adapters. Cable…

UPC: 075114355957


Documents & Media
BrochureManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 25 kV Power Cable Joint, SKU 25PCJ2H2280, is designed for reliable termination of medium voltage power cables. It features a Style 2 Universal Housing, ensuring broad compatibility, and comes with separate cable adapters for a precise fit. The joint is engineered for copper conductors, specifically accommodating cable sizes from 280 to 250 kcmil, whether stranded or compressed. The insulation diameter range for this model is H, measuring between 0.850 and 1.050 inches, critical for ensuring a secure and electrically sound connection. This product is suitable for applications requiring robust and dependable cable termination in power distribution networks. The UNSPSC code for this item is 39121452. ABB Installation Products is the manufacturer. The country of origin is not specified in the provided data. Focus on the precise cable specifications and insulation diameter for correct application. This joint provides a secure mechanical and electrical connection for the specified cable types and sizes, essential for maintaining system integrity in power infrastructure.
  • 25 kV Power Cable Joint
  • Style 2 Universal Housing
  • Separate Cable Adapters Included
  • Cable Insulation Diameter: H (.850 - 1.050 inch)
  • Copper Conductor, 280-250 kcmil Stranded/Compressed

Specifications

Material
Copper Conductor
Series
Style 2 Universal Housing
Size
280 - 250 kcmil Stranded/Compressed
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25 kV Power Cable Joint, Style 2 Universal Housing and Separate Cable Adapters. Cable Insulation Diameter H - .850 - 1.050 inch, Copper Conductor, Cable Size 250 - 2/0 Stranded, Compressed or 3/0 Compact. Solid

25PCJ2H2250

25 kV Power Cable Joint, Style 2 Universal Housing and Separate Cable Adapters. Cable Insulation Diameter H - .850 - 1.050 inch, Copper Conductor, Cable Size 250 - 2/0 Stranded, Compressed or 3/0 Compact. Solid
15kV, Power Cable Joint with SG3 - Cold-Shrinkable Jacket Seal with Copper Braid and Constant Force Spring. Cable Insulation Diameter K - 1.090 to 1.310 inch. Copper Compression Lug, Conductor Size 330 - 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact.

15PCJ1K2330-SG3

15kV, Power Cable Joint with SG3 - Cold-Shrinkable Jacket Seal with Copper Braid and Constant Force Spring. Cable Insulation Diameter K - 1.090 to 1.310 inch. Copper Compression Lug, Conductor Size 330 - 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded #1 or Solid 1/0. Overall Length 14-3/8 inch, Diameter 2-25/32 inch.

25PCJ1L1230

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded #1 or Solid 1/0. Overall Length 14-3/8 inch, Diameter 2-25/32 inch.
69kV Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style - 1, Insulation Diameter Range R - 2.20 to 2.58 inch, Aluminum Connector, Connector Code 40P - 1.036 to 1.100 inch, Bore Size 1.125, Type Shield - Copper Tape, Metallic Screen Continuity Kit - 4/0 Welding cable, 6 Foot Quantity 4 but 1 without Split Bolts, Outer Jacket Restoration Kit - Heat Sink.

69TCJS1R140PVAGNB

69kV Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style - 1, Insulation Diameter Range R - 2.20 to 2.58 inch, Aluminum Connector, Connector Code 40P - 1.036 to 1.100 inch, Bore Size 1.125, Type Shield - Copper Tape, Metallic Screen Continuity Kit - 4/0 Welding cable, 6 Foot Quantity 4 but 1 without Split Bolts, Outer Jacket Restoration Kit - Heat Sink.
High Temperature Insulated Nylon Wire Joints for Minimum Wire Range (3) #16 to Maximum Wire Range (3) #14, White

RC6-HT

High Temperature Insulated Nylon Wire Joints for Minimum Wire Range (3) #16 to Maximum Wire Range (3) #14, White
High Temperature Insulated Nylon Wire Joints for Minimum Wire Range (2) #18 to Maximum Wire Range (2) #16, White

RB4-HT

High Temperature Insulated Nylon Wire Joints for Minimum Wire Range (2) #18 to Maximum Wire Range (2) #16, White
Nylon Insulated High Temperature Crimp-On Wire Joint, Length 1.00 Inches, Width .53 Inches, Wire Range 3#14 - 4#12, Color White, 500 Pack

RP7-HT

Nylon Insulated High Temperature Crimp-On Wire Joint, Length 1.00 Inches, Width .53 Inches, Wire Range 3#14 - 4#12, Color White, 500 Pack
Nylon Insulated High Temperature Crimp-On Wire Joint, Length .78 Inches, Width .31 Inches, Wire Range 2#18 - 2#16, Color White

RB44-HT

Nylon Insulated High Temperature Crimp-On Wire Joint, Length .78 Inches, Width .31 Inches, Wire Range 2#18 - 2#16, Color White

Frequently Asked Questions

What are Elastimold PCJ power cable joints used for?

They provide permanent, fully shielded, and submersible splices for straight splicing of similar cables or transition splicing of different cable sizes. They can be installed in direct-burial, underground vault, and overhead applications.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

Can copper connectors be used with aluminum conductors?

No, copper connectors included in the kit are suitable for splicing copper conductors to copper conductors only and should not be used on aluminum conductors.

What type of conductors are compatible with PCJ joints?

PCJ power cable joints can be used with copper or aluminum conductors. Specific connectors are required for copper-to-copper connections.

What is the short-time current rating for PCJ joints?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What is the continuous current rating of PCJ joints?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

What safety standards do PCJ power cable joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

What is the pull force rating for PCJ cable joints?

The pin-and-socket interlock of the PCJ power cable joints is designed to withstand a pull force of up to 500 lb.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

What conductor sizes are compatible with PCJ joints?

PCJ power cable joints can be used with copper or aluminum conductors up to 1250 kcmil.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.