Authorized ABB Distributor (Installation Products)
ABB - Installation Products 25PCJ1K2330 - 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size kcmil Stranded-Compressed 500, Solid-Compact 600.

ABB Installation Products 25PCJ1K2330 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 075114371155


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 25kV Power Cable Joint, SKU 25PCJ1K2330, is designed for reliable and secure termination of medium-voltage power cables. Featuring a single-piece housing construction, this joint simplifies installation while ensuring robust protection for your electrical infrastructure. It is specifically engineered to accommodate cable insulation diameters ranging from 1.090 inches to 1.310 inches. The joint is suitable for aluminum conductors, supporting both stranded-compressed sizes of 500 kcmil and solid-compact sizes of 600 kcmil. This product from ABB's Installation Products division provides a dependable connection point for power distribution systems, critical for utilities, industrial facilities, and commercial installations requiring safe and efficient power transmission. Its design prioritizes ease of use and long-term performance in standard operational environments. The UNSPSC code for this product is 39121452, indicating its classification within electrical connectors and accessories.
  • 25kV voltage rating for medium-voltage applications
  • Single-piece housing for simplified installation
  • Accommodates cable insulation diameters from 1.090" to 1.310"
  • Designed for aluminum conductors: 500 kcmil stranded-compressed, 600 kcmil solid-compact
  • Manufacturer: ABB - Installation Products

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
500 kcmil , 600 kcmil
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. CTN.

25PCJ1H (CTN)

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. CTN.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Side 1 - Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded/Compressed #2 or Solid/Compact #1. Side 2 - Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded/Compressed #3 or Solid/Compact #2. Length 16.38 inch x 2.78 inch Diameter.

15PCJ2-G1220-F1210

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Side 1 - Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded/Compressed #2 or Solid/Compact #1. Side 2 - Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded/Compressed #3 or Solid/Compact #2. Length 16.38 inch x 2.78 inch Diameter.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper/no connector required, Connector Code 47P - Conductor Diameter Range - 1.378-1.425 inch (35.00-36.19mm), Heatsink Size 5 - Outside Diameter 2.750 inch ( 69.85mm), Heatsink Bore - M - 1.468 inch Diameter. Type Shield - A - Copper Tape, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink standard package

69TCJS44247P5MANNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper/no connector required, Connector Code 47P - Conductor Diameter Range - 1.378-1.425 inch (35.00-36.19mm), Heatsink Size 5 - Outside Diameter 2.750 inch ( 69.85mm), Heatsink Bore - M - 1.468 inch Diameter. Type Shield - A - Copper Tape, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink standard package
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. (K) Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size 330 - AWG Stranded 500. (H) Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size 270 - 4/0 Stranded/Compressed or 250 kcmil Solid/Compact. Cold-Shrinkable Jacket Seal Included.

15PCJ2K1330-H1270-S

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. (K) Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size 330 - AWG Stranded 500. (H) Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size 270 - 4/0 Stranded/Compressed or 250 kcmil Solid/Compact. Cold-Shrinkable Jacket Seal Included.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. N Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. 410 Conductor Size AWG Stranded 1000 kcmil. K Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. 330 Conductor Size AWG Stranded 500 kcmil.

15PCJ2N1410-K1330

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. N Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. 410 Conductor Size AWG Stranded 1000 kcmil. K Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. 330 Conductor Size AWG Stranded 500 kcmil.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size Stranded/Compressed 1250 kcmil. Includes Cold-Shrinkable Jacket Seal.

25PCJ1P1440-S

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size Stranded/Compressed 1250 kcmil. Includes Cold-Shrinkable Jacket Seal.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Side A Cable Insulation Diameter 0.750 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded/Compressed 1/0 or Solid/Compact 2/0. Side B Cable Insulation Diameter 0.750 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded/Compressed #1 or Solid/Compact 1/0.

15PCJ2G1240-G1230

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Side A Cable Insulation Diameter 0.750 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded/Compressed 1/0 or Solid/Compact 2/0. Side B Cable Insulation Diameter 0.750 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded/Compressed #1 or Solid/Compact 1/0.
15kV Power Cable Joint Splice - Style 2 with Universal Housing and Separate Cable Adapters. H1270 - Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. G1250 - Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 or Solid 3/0. No Sealing Kit.

15PCJ2H1270G1250

15kV Power Cable Joint Splice - Style 2 with Universal Housing and Separate Cable Adapters. H1270 - Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. G1250 - Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 or Solid 3/0. No Sealing Kit.

Frequently Asked Questions

What are Elastimold PCJ power cable joints?

They are cable joints with permanently crimped connectors inside EPDM rubber housings, offering reliable splicing for similar or different cable sizes up to 1250 kcmil.

What is the short-time current rating of PCJ joints?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What is the continuous current rating of PCJ joints?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating they are used with.

What is the BIL impulse withstand for a 25 kV joint?

For a 25 kV class PCJ joint, the BIL impulse withstand (1.2 x 50 μsec. wave) is 150 kV.

Can aluminum connectors be used for copper cables?

Aluminum compression connectors splice aluminum-to-aluminum or aluminum-to-copper conductors. An all-copper connector is required for copper-to-copper connections.

What is the pull force rating for PCJ joints?

The pin-and-socket interlock design of the PCJ power cable joints is capable of withstanding a pull force of up to 500 lb.

What safety standards do PCJ joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

What cable types are PCJ joints designed for?

PCJ joints are designed for UD cable with concentric neutral and extruded insulation shielding. They also work with fabric-tape or lead-jacketed cables when used with proper adapters.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

What conductor types are compatible with PCJ joints?

PCJ power cable joints are compatible with both copper and aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

How to Install the 25PCJ1 Series Straight Joint

This guide provides step-by-step instructions for the permanent, fully shielded, fully submersible installation of the 25PCJ1 series straight joint for wire shielded cables, connecting aluminum and/or copper conductors.

Estimated time: 2h

Tools needed:

Cable cutters, Measuring tape, Cable jacket removal tool, Cable insulation removal tool, Insulation shield removal tool, Cleaning supplies, Wire brush (for aluminum conductors), Crimping tool, Cable tie tool (recommended T&B WT3D for 35kV), Wire strippers

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), User-supplied conductor connector, Grounding wire (#14 AWG copper or equivalent, if needed), DELTECt Cable ties (TYD5135, for 35kV only), Appropriate connector for grounding wires

  1. Ensure Safety and Inspect Components

    De-energize all apparatus in the work area before beginning installation. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices. Inspect all package contents and components for damage, proper rating, and compatibility with cables and mating products.

  2. Prepare Cables for Joint Assembly

    Overlap both cables and cut them to 12 inches (305mm) from the joint centerline. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires and then cut both cables at the joint centerline.

  3. Prepare Cable 1 and Store Housing

    Taper the edge of Cable 1 insulation from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends, then slide the housing onto Cable 1 up to the shield wires.

  4. Prepare Cables for Splice Installation

    Carefully remove the cable insulation and then the insulation shield from both cables. Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor.

  5. Install the Splice

    If conductors are aluminum, wire-brush them thoroughly before immediately inserting them into the splice. Crimp the splice according to its recommendations. Wipe off any excess inhibitor and remove any sharp protrusions or burrs from the crimped splice and surrounding area. Clean the cables as indicated and lubricate them to create a ramp of lubricant at the edge of the insulation shield.

  6. Complete Joint Assembly

    Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV installations only, install two DELTECt Cable ties on each end of the cable entrance as specified, using a T&B WT3D tool if available, and remove the yellow pin from the joint grounding eye. Retrain and secure the shield wires to the ends of the joint. Insert one shield wire from each cable (if #14 AWG or larger, otherwise use separate #14 AWG copper wire) through the joint grounding eye. Connect all joint grounding wires and remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket over both cables and the joint housing where applicable.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.