Authorized ABB Distributor (Installation Products)
ABB - Installation Products 25PCJ1J1240 - 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

ABB Installation Products 25PCJ1J1240 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786645053


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 25kV Power Cable Joint, SKU 25PCJ1J1240, is a critical component for reliable medium voltage power distribution. Designed for 25kV applications and rated per IEEE Standard 404, this Style 1 joint offers a permanent, fully shielded, and fully submersible solution for joining cable runs or repairing damaged cables. Its single-piece molded rubber housing ensures robust protection and straightforward installation, whether directly buried or installed in a vault. The joint accommodates cable insulation diameters ranging from 0.980 inches to 1.180 inches, specifically designed for aluminum conductors with stranded sizes 1/0 AWG and solid sizes 2/0 AWG. The molded conductive shield provides a virtually indestructible ground shield for deadfront construction, and the cable entrance design ensures electrical and water seal integrity without the need for taping. Key specifications include a 150kV BIL impulse withstand, 52kV AC withstand, and a continuous current rating equivalent to the cable's rating, with a short-time rating up to 35kA. Connectors meet ANSI C119.4 Class A and Class 3 ratings. The grounding eye offers a convenient connection point for the molded conductive shield. This product ensures a secure and insulated connection, vital for maintaining power system integrity in demanding electrical infrastructure. UNSPSC Code: 39121452.
  • 25kV Rated Power Cable Joint per IEEE Standard 404
  • Accommodates 0.980" to 1.180" cable insulation diameter
  • Suitable for 1/0 AWG stranded and 2/0 AWG solid aluminum conductors
  • Fully shielded, fully submersible molded rubber housing
  • Single-piece housing for straightforward installation

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
1/0 STR AWG , 2/0 SOL AWG
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.7500 L
Package Weight (Metric)
0.7940 kg
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

25PCJ2J1240-H1240

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
25kV Power Cable Joint With Customer Specific Modifications

25PCJ-T

25kV Power Cable Joint With Customer Specific Modifications
35kV Power Cable Joint, Cable Insulation Diameter 1.515 inch to 1.780 inch.

35PCJ-N

35kV Power Cable Joint, Cable Insulation Diameter 1.515 inch to 1.780 inch.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Conductor. Conductor Size AWG Stranded 1000.

35PCJ1P2410

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Conductor. Conductor Size AWG Stranded 1000.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 600 /Solid 700.

35PCJ1N1350

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 600 /Solid 700.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 450.

25PCJ1L1320

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 450.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Conductor. Conductor Size AWG Stranded 750.

35PCJ1P2380

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Conductor. Conductor Size AWG Stranded 750.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

25PCJ1G1230-1220

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

Frequently Asked Questions

What are Elastimold PCJ power cable joints used for?

They are used for straight splicing of two similar cables or transition splicing of different cable sizes, providing a permanent, fully shielded, and submersible splice.

What is the continuous current rating of PCJ joints?

The continuous current rating of PCJ power cable joints is equal to that of the cable rating.

What type of cable insulation shielding is compatible?

PCJ joints are designed for use with UD cable with concentric neutral and extruded insulation shielding, and also work with fabric-tape shielded or lead-jacketed cables.

Can copper connectors be used on aluminum conductors?

No, copper compression connectors are suitable for splicing copper conductors to copper conductors only and should not be used on aluminum conductors.

What standards do PCJ joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings. Electrical ratings meet IEEE 404.

What is the pull force withstand capability?

The pin-and-socket interlock design of the PCJ power cable joints can withstand a pull force of up to 500 lb.

What is the short-time current rating?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What environments can PCJ cable joints be installed in?

They can be installed in direct-burial, underground vault, and even overhead applications, providing a permanent, fully shielded, and submersible splice.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables, while Style 2 includes separate cable adapters for transition splicing between different cable sizes.

What is the maximum conductor size supported?

The PCJ power cable joints support conductor sizes up to 1250 kcmil for both copper and aluminum conductors.

How to Install a 15/25/35PCJ1 Series Straight Joint

This guide provides detailed instructions for the permanent, fully shielded, and submersible installation of a 15/25/35PCJ1 series straight joint for wire shielded cables, connecting aluminum to aluminum or aluminum to copper conductors.

Estimated time: 2h

Tools needed:

Cable stripping tools, Measuring tape or ruler, Knife or tapering tool, Wire-brush, Crimping tool, T&B WT3D tool (for 35kV only)

Supplies needed:

Joint Housing (provided), Splice (Conductor Contact) (provided), Lubricant (DO NOT SUBSTITUTE) (provided), Appropriate connector (user supplied, for grounding wires), DELTECt Cable ties (TYD5135, for 35kV only), #14 AWG copper wire or equivalent (if shield wires are smaller than #14 AWG), Cable jacket reconstruction material (where applicable)

  1. Ensure Safety and Inspect Components

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products in the work area. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all package contents and components for damage, proper rating, and compatibility with the cable and mating products. Read the entire installation instructions before starting.

  2. Prepare Cables for Initial Cuts

    Overlap both cables and mark a cut line 12 inches (305mm) from the center line of the joint. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm) from the joint centerline. Fold back the shield wires.

  3. Cut Cables and Prepare Cable 1

    Cut both cables at the center line of the joint. Taper the edge of Cable 1's insulation shield at least 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Slide the joint housing onto Cable 1 up to the shield wires.

  4. Prepare Cables for Splice Installation

    Carefully remove the cable insulation and then the insulation shield from both cables. DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR. For 500 MCM - 750 MCM conductors, remove insulation to 2 1/2 inches (64mm) and insulation shield to 6 1/4 inches (159mm). For 1000 MCM conductors, remove insulation to 2 3/8 inches (68mm) and insulation shield to 6 3/8 inches (162mm).

  5. Install and Crimp the Splice

    If conductors are aluminum, wire-brush them immediately before insertion into the splice. Insert conductors into the splice and check the dimension against the 'Max Check Before' table (6 inches for 500-750 MCM; 6 7/8 inches for 1000 MCM). If it exceeds, redo the assembly. Crimp the splice following the recommendations provided with it. Wipe off any excess inhibitor. Check the distance between cable insulations against the 'Max Check After' table (6 1/4 inches for 500-750 MCM; 6 1/2 inches for 1000 MCM). If it exceeds, redo the assembly.

  6. Clean and Lubricate Splice Area

    Remove any sharp protrusions or burrs generated during crimping. Ensure all metal chips and filings are removed from the splice and joint assembly area prior to sliding the joint. Clean the cables where indicated and apply lubricant in the direction of the arrows to provide a build-up or ramp of lubricant at the edge of the insulation shield.

  7. Position Joint Housing

    Slide the joint housing into its final position. Proper positioning is ensured by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield.

  8. Install 35kV Cable Ties (If Applicable)

    For 35kV installations ONLY: Install two DELTECt Cable ties on each end of the cable entrance. Begin by installing the outer ties approximately 1/4 inch (6mm) from the edge of the splice, then install the second ties approximately 1/4 inch (6mm) from the first with an offset of the locking heads. The T&B WT3D tool (not included) is recommended to tighten and trim the ties. Remove the yellow pin from the joint grounding eye and discard it.

  9. Connect Grounding Wires

    Retrain the shield wires and secure them to the ends of the joint as shown. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye. Repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate user-supplied connector.

  10. Reconstruct Cable Jacket

    Reconstruct the cable jacket (where applicable) over both cables and the joint housing to complete the installation.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.