Authorized ABB Distributor (Installation Products)
ABB - Installation Products 16THG-HA-0270-4 - Gray, Single Piece Terminator (Class 1) includes Contract Rod, Ground Strap and Rain Cap. 15/25kv, Cable Insulation Diameter .980 to 1.115 inches, Conductor size -4/0 Stranded/Compressed.

ABB Installation Products 16THG-HA-0270-4 Gray, Single Piece Terminator (Class 1) includes Contract Rod, Ground Strap and Rain…

UPC: 783786662388


Documents & Media
Installation InstructionsManufacturer Product Website

Contact for Pricing

Minimum Qty: 10

Multiplier: 10

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 16THG-HA-0270-4 is a Class 1 single-piece terminator engineered for medium-voltage cable systems operating at 15/25kV. Designed for cable insulation diameters between 0.980 and 1.115 inches, this terminator supports -4/0 stranded/compressed conductors, providing a reliable termination solution for medium-voltage applications. The integrated design includes a contract rod, ground strap, and rain cap, eliminating the need for multiple components during installation. The gray rubber housing is constructed for durability in outdoor and industrial environments, ensuring long-term performance under varying conditions. Installation follows a straightforward process: train the cable, secure concentric wires, cut and remove insulation, and install the terminator per the included crimp chart. The product includes all necessary components—rubber housing, conductor contact, cap, ground strap, washer, lubricant, wiping cloth, and installation instructions—packaged for immediate deployment. This terminator is ideal for power distribution systems, industrial plants, and utility applications where medium-voltage cable termination is required. The compact design and included accessories reduce installation time and complexity, making it a cost-effective choice for maintenance and new installations. Compatibility is ensured with standard medium-voltage cable systems, and the product is designed for use in Class 1 termination environments.
  • Class 1 single-piece terminator for 15/25kV medium-voltage systems
  • Supports cable insulation diameters from 0.980 to 1.115 inches
  • Compatible with -4/0 stranded/compressed conductors
  • Includes contract rod, ground strap, and rain cap for complete installation
  • Gray rubber housing designed for outdoor and industrial durability

Specifications

Application
Used in Switchgear and Padmounted Transformers
Color
Gray
Connection
Slide-On
Material
EPDM-Rubber Housing
Poles
1
Series
Class 1 Terminator
Size
Complete unit 22 inches long
Standard
IEEE 48-1975
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Single-Piece Terminator
Voltage Rating
15/25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.0000 L
Package Weight (Metric)
1.3610 kg
Gray, Single Piece Terminator (Class 1) includes Contract Rod, Ground Strap and Rain Cap. 15/25kv, Cable Insulation Diameter .675 to .785 inches, Conductor size - #2 Stranded/Compressed or #1 Compact/Solid.

16THG-FB-0220-4

Gray, Single Piece Terminator (Class 1) includes Contract Rod, Ground Strap and Rain Cap. 15/25kv, Cable Insulation Diameter .675 to .785 inches, Conductor size - #2 Stranded/Compressed or #1 Compact/Solid.
Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size 2/0 - Stranded/Compressed, 3/0 Compact/Solid

00700250

Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size 2/0 - Stranded/Compressed, 3/0 Compact/Solid
Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size #1 - Stranded/Compressed, 1/0 Compact/Solid

00700230

Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size #1 - Stranded/Compressed, 1/0 Compact/Solid
Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size #4 - Stranded/Compressed, #3 Compact/Solid

00700200

Universal Aluminum Rod Contact for Aluminum or Copper Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size #4 - Stranded/Compressed, #3 Compact/Solid
200 Amp, 15/25kV, Deadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.625 inch to 0.735 inch. 9.25 inches Long. Plastic.

10EP-FAB

200 Amp, 15/25kV, Deadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.625 inch to 0.735 inch. 9.25 inches Long. Plastic.
200 Amp, 15/25kV, Deadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.575 inch to 0.685 inch. 9.25 inches Long. Plastic.

10EP-FA

200 Amp, 15/25kV, Deadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.575 inch to 0.685 inch. 9.25 inches Long. Plastic.
15/25kV 200 Amp, Deadbreak Grounding Plug, Bails are required, but not included, order separately.

151-GP

15/25kV 200 Amp, Deadbreak Grounding Plug, Bails are required, but not included, order separately.
15KV, 200 Amp, Feed Thru with Stainless Steel Bracket

164FT-SS

15KV, 200 Amp, Feed Thru with Stainless Steel Bracket

Frequently Asked Questions

What voltage rating does this terminator support?

This terminator is rated for 15/25kV medium-voltage applications.

What cable insulation diameter range does it accommodate?

The terminator supports cable insulation diameters between 0.980 and 1.115 inches.

What conductor size is compatible with this terminator?

It is designed for -4/0 stranded or compressed conductors.

Does this terminator include all necessary components?

Yes, it includes a contract rod, ground strap, and rain cap as a single unit.

Is this terminator suitable for outdoor use?

The gray housing is constructed for durability in outdoor and industrial environments.

What class of termination does this product provide?

This terminator meets Class 1 termination requirements.

How to Install 16THG Single-Piece Outdoor Terminators

This guide provides step-by-step instructions for the safe and correct installation of 16THG single-piece outdoor terminators, including cable preparation, component assembly, and grounding procedures. Ensure all apparatus is de-energized before starting.

Estimated time: 1h 30m

Tools needed:

Cutting tool, Measuring tape or ruler, Plastic electrical tape, Wire brush (for aluminum conductors), Wiping cloth, Approved safety solvent, Crimping tool

Supplies needed:

16THG Rubber Housing, Conductor Contact (appropriate for cable size), Rubber Cap, Ground Strap, Plain Washer, Lubricant (supplied or ELASTIMOLD approved), No. 14 AWG (2.5mm2) copper wire, Cable (to be terminated)

  1. Prepare the Cable for Termination

    DANGER: Ensure all apparatus is de-energized during installation. Train the cable into position. Unwrap and fold back concentric wires 15 inches (380mm) from the end of the cable. Secure these concentric wires at this point by wrapping with plastic electrical tape or a strand of wire (do not use a concentric neutral wire). Twist the loose concentric wires together to form a ground lead.

  2. Remove Cable Insulation

    Carefully cut and remove the insulation from the end of the cable according to the distance specified in Table 1 for your conductor size. Avoid nicking or damaging the conductor strands. If the conductor is damaged, cut the end off and restart this step.

  3. Prepare the Extruded Cable Insulation Shield

    Carefully cut and remove the exposed extruded cable insulation shield a distance of 9 inches (229mm) from the end of the insulation. Cut the shield squarely, being careful not to nick or cut the cable insulation. If the insulation is damaged, cut off and restart. Bevel the edge of the cable insulation not more than 1/4 inch (6.4mm).

  4. Clean Cable Surfaces

    Clean the outer jacket and thoroughly clean the insulation to remove all traces of semi-conducting residue. Wipe with a rag soaked with an approved safety solvent, always wiping from the end of the cable toward the outer jacket. Failure to remove all conductive residue will cause product failure.

  5. Mark and Protect the Conductor

    Mark the extruded cable insulation shield by wrapping a piece of tape exactly 1 inch (25.4mm) from its end. To prevent the cable conductor from damaging the inside of the terminator, wrap a piece of tape around the leading edge of the conductor. Damage to inner surfaces can lead to unsatisfactory performance.

  6. Apply Lubricant to Terminator Housing

    Before proceeding, verify that the cutback and taping from Steps 3 and 5 are correct. Apply the supplied lubricant or an ELASTIMOLD approved lubricant sparingly to the cable insulation and to the inside base surface of the terminator. DO NOT SUBSTITUTE other lubricants, as they may be harmful to the product.

  7. Install the Terminator Housing

    Slide the terminator housing down onto the cable using a spiral motion. Ensure the base of the terminator housing aligns with the wrap of tape on the extruded cable insulation shield, and the top of the housing is flush with the end of the cable insulation. Improper positioning can lead to unsatisfactory performance.

  8. Verify Terminator Housing Position

    Check the dimension from the top of the terminator housing to the end of the cable conductor. Refer to Table 1 for the correct dimension for the specific contact being used. If the housing does not align with the tape, is not flush with the cable insulation, or the check dimension is incorrect, remove the housing and re-check Steps 3 and 5 before proceeding.

  9. Prepare and Install the Conductor Contact and Cap

    Completely remove the wrap of tape from the cable conductor. If using an aluminum conductor, wire brush the bare conductors. Place the plain washer over the bared conductor. Immediately slide the conductor contact onto the conductor. Carefully clean any excess inhibitor from the area around the top of the terminator. If using .840” or .938” OD barrels (as per Step 9A), apply lubricant to the inside of the rubber cap and outside of the contact, then slide the rubber cap onto the contact, ensuring it is fully seated and snaps into place over the matching ring on the terminator housing. For .625” OD barrels (as per Step 9B), the rubber cap is assembled later.

  10. Crimp the Conductor Contact

    For all rod contacts (.625”, .840”, and .938” barrels), begin crimping at the upper (or top) crimp mark on the contact, working towards the terminator. Rotate each successive crimp 90˚ or 180˚. While crimping, hold the contact tightly, pushing down towards the plain washer. Refer to the crimp chart provided for the specific -4 style crimp barrel.

  11. Finalize Rubber Cap Installation

    If using .840” or .938” OD barrels (as per Step 11A), check the position of the terminator cap to ensure it did not move during crimping; reposition if necessary. If using .625” OD barrels (as per Step 11B), carefully wipe excess inhibitor from the contact and terminator housing after crimping. Apply lubricant sparingly to the inside of the rubber cap and the outside of the conductor contact. Slide the rubber cap down the contact so it is fully seated and locked on the terminator housing, ensuring the groove in the bottom snaps into place over the matching ring.

  12. Make the Takeoff Connection

    Make the takeoff on the universal rod contact as desired, connecting the appropriate conductor.

  13. Install and Connect the Grounding Clamp

    If the terminator is not bracketed, place the grounding clamp around the terminator base, directly under the shoulder and above the projecting rib (the 1/2 inch / 12.7mm dimension ensures it cannot move). Remove the marking tape and wipe off any grease on the cable. Insert a separate No. 14 AWG (2.5mm2) copper wire or equivalent into the crimp lug supplied with the ground strap and crimp it. Do not use one of the twisted concentric neutral wires. Connect the loose end of the No. 14 AWG wire to the concentric neutral wires on the cable and securely connect the twisted concentric neutral wires to ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.