ABB - Installation Products 168FLR1-B0220 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact.
More images

ABB Installation Products 168FLR1-B0220 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port…

UPC: 783786460878


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 168FLR1-B0220 is a molded current limiting fuse housing designed for electrical protection applications. This unit features a nominal fuse voltage rating of 8.3kV, providing reliable overcurrent protection for medium voltage systems. It is equipped with two capacitive test ports, facilitating safe and efficient testing of the fuse and associated circuitry. The housing is designed for small form factor installations and accommodates cable insulation diameters ranging from 0.635 to 0.905 inches (16-23mm). For conductor connections, the housing supports aluminum conductors of size 2 AWG stranded/compressed or 1 AWG solid/compact. This product, manufactured by ABB Installation Products, is suitable for applications requiring precise current limitation and robust housing for medium voltage fuses. Its specific design considerations for cable insulation and conductor size ensure proper fit and reliable electrical contact. The UNSPSC code for this product is 39121421.
  • Nominal Fuse Voltage Rating: 8.3kV
  • Fuse Test Port: Two Capacitive Test Ports
  • Cable Insulation Diameter: 0.635 - 0.905 inch / 16-23mm
  • Aluminum Conductor Size: 2 AWG Stranded/Compressed, 1 AWG Solid/Compact
  • Manufacturer: ABB - Installation Products

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Insulation
True
Length
16.87 in
Length
428.498 mm
Material
EPDM-Rubber
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 15kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector
Voltage Rating
8.3 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
7.7700 L
Package Weight (Metric)
3.5250 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit

168FLR1-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact.

168FLR1-B0230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Solid/Compact.

168FLR1-A0210

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.

168FLR1-B0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded/Compressed.

168FLR1-D0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded/Compressed.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact.

168FLR1-C0230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact.

168FLR1-B0260

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.

168FLR1-A0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.

Frequently Asked Questions

What is the primary application of the 168FLR?

The 168FLR combines full-range current-limiting fusing with 15kV hot stick operable, loadbreak elbow switching. It protects light duty underground distribution systems like sub-loops and radial taps.

What is the impulse withstand rating of the 168FLR?

The 168FLR has a 95kV BIL impulse withstand rating, based on a 1.2 x 50 microsecond wave.

What is the frequency rating of the 168FLR?

The 168FLR is rated for a frequency of 50/60 Hz.

What items are included in the 168FLR kit?

Each kit contains an elbow connector housing, a crimp connector, a probe lug, four tubes of lubricant, installation instructions, and a crimp chart.

What types of conductors are compatible with the lugs?

Copper compression lugs are for copper conductors only. Bi-metal compression lugs with universal aluminum barrels are suitable for copper or aluminum conductors.

What industry standards does the 168FLR meet?

The 168FLR meets IEEE 386, ANSI C37.40, ANSI C37.41, and ANSI C37.47, Latest Revision.

Is the 168FLR fused elbow submersible?

Yes, the Elastimold 168FLR fused elbow is fully sealed and submersible. It also insulates, shields, and eliminates exposed live parts.

What is the current rating range for the 168FLR?

The 168FLR has a current rating range of 3-80 Amps. It also features a 50,000 Amp symmetrical interrupting capability.

What voltage class is the 168FLR designed for?

The 168FLR is designed for the 15kV voltage class. It has an 8.3kV nominal fuse voltage and a 10kV maximum rated fuse voltage.

What is the AC one-minute withstand voltage?

The 168FLR has a 34kV AC one-minute withstand rating. It also has a 53kV DC 15-minute withstand rating.

How to Install the 168FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the safe and proper installation of the 168FLR Loadbreak Fused Elbow Connector, including cable preparation, assembly, and neutral connections. Ensure all apparatus is de-energized before beginning installation.

Estimated time: 1h 30m

Tools needed:

Wire brush, Crimp tool, Probe Wrench, Allen Wrench (torque limiting), Hotstick

Supplies needed:

168FLR Kit (Cable Half Housing, Elbow Half Housing, Fuse, Compression Lug, Probe, Probe Connector, Hose Clamp, Lubricant), 200ECS Cold Shrink Cable Seal (optional), Copper wire (No. 14 AWG / 2.5mm or equivalent), Grounding connector

  1. De-energize and Prepare Cable Length

    Ensure all apparatus is de-energized before starting any installation work. Using the bushing centerline as a reference, cut excess cable off, leaving a minimum of 20 inches beyond the bushing. If using, slide the 200ECS Cold Shrink Cable Seal onto the cable. Remove the cable jacket for a length of "A" (11-1/2" for FLR-1) + 7-3/8" from the bushing centerline. Unwrap and fold the concentric neutral wires back over the jacket, then bind them securely. Squarely cut the cable a distance of "A" from the bushing centerline, ensuring at least 7-3/8" of cable remains for termination.

  2. Prepare Cable End and Install Compression Lug

    Cut 1-1/8" squarely from the cable end, being careful not to nick the conductor. Wire brush the bare aluminum conductors thoroughly. Immediately install the compression lug onto the conductor. Rotate the lug to spread the inhibitor. Crimp the unthreaded end of the lug to the conductor, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable. Remove the insulation shield 5-1/2" from the end of the lug. Bevel the insulation end a maximum of 1/8". Thoroughly clean the insulation to remove all traces of conductive residue.

  3. Assemble Cable Half Housing and Fuse

    Apply the supplied lubricant to the outside of the connector, cable insulation, conductive shield, and the cable entrance end of the Fused Elbow cable half. Do not substitute lubricant. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface "A". Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and hand-thread it into the cable connector. Pull the cable half housing up against the bottom of the tightened fuse. CAUTION: Hand tighten only; the fuse stud will fracture if over-torqued.

  4. Attach Probe Connector and Align Test Point

    Attach the probe connector to the fuse terminal. Rotate the probe connector so its flats are perpendicular to the mating bushing. Lock the probe connector in position and tighten the setscrews using the special torque-limiting Allen wrench supplied in the fuse kit. Rotate the cable half of the Fused Elbow so its test point is perpendicular to the flats on the probe connector.

  5. Assemble Elbow Half Housing and Probe

    Apply lubricant to the elbow half of the fused elbow. Assemble the elbow half to the cable half, ensuring the cable half's cuff overlaps the elbow half by 3/4". Verify the probe connector faces the opening of the fused elbow half and that the two test points are in line. Insert the probe into the probe connector. Push on the cable if necessary to align the probe with the fuse. Hand-start the threads carefully to avoid cross-threading. Use the special torque-limiting Allen wrench supplied; insert the short end into the hole in the probe and tighten until the wrench bends and remains bent. Position the hose clamp as shown in the diagram and tighten it. DO NOT OVERTIGHTEN.

  6. Connect Concentric Neutral Wires

    Use a separate copper wire (No. 14 AWG / 2.5mm or equivalent) to insert one end through each grounding eye on both the elbow and cable housings. Twist tightly, taking care not to damage the eyes. Finish installing the 200ECS jacket seal if it was used. Twist all neutral wires together, ensuring not to damage the grounding eyes, and connect them to ground using an appropriate connector. Provide adequate slack in the wires to allow for elbow operation.

  7. Prepare for Final Connection to Bushing

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. WARNING: Only lubricate if the transformer and elbow are known to be de-energized. Do not attempt to operate or connect the elbow by hand. Use a full insulated "hotstick" type tool for connection as per operating instructions.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.